Inspections for the day of: Tuesday, October 24, 2006.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-03924 Permanent Service10/23/200610/24/200610/24/2006 4:35:00 PMPFAIL
My cell phone number is ###-####, thanks Randy; Phone #: ###-#### Internet Inspection Request from: Randy Fletcher called left corr notice, nec 408.4 circuit directory shall be complete, concise, and explanatory for each circuit, 110.3(B) listed equipment shall be installed and used in accordance with instructions-Sq D breakers, 314.15(A) fittings in wet locations shall be listed for use in wet locations(emt connectors to recpt), 348.12 fmc shall not be used in wet locations unless conductors are approved for wet locations, 352.30 rnc shall be secured within 3' of box
ELE06-03893 Temporary Service10/24/200610/24/200610/24/2006 4:13:00 PMPPASS
Scheduled by a contractor via Hello! on 10/24/2006 at 7:53:16 AM. Contact: ###-####. t/s o/h n ok
ELE06-02468 Electrical Rough-In10/24/200610/24/200610/24/2006 3:41:55 PMPPART
contact: John Stebly - Underground inspection; Phone #: ###-#### Internet Inspection Request from: Deb McCoy south side only u/g ok to cover
ELE06-02976 Electrical Rough-In10/24/200610/24/200610/24/2006 3:18:37 PMPPASS
sergey; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr made, ric ok ,need to see service ltr
ELE06-03178 Final10/23/200610/24/200610/24/2006 2:46:00 PMPPASS
any questions please call Jesse Collingsworth; Phone #: ###-#### Internet Inspection Request from: Jeff Radford ok to final, signed occ card
ELE06-01275 Final10/23/200610/24/200610/24/2006 1:45:29 PMPFAIL
This will be a final inspection. Please see Marvin Miller. Thank you; Phone #: ###-#### Internet Inspection Request from: Laura Longshaw left corr notice, met contr, nec 358.30 emt shall be secured within 3' of box, BCC 4-05-33(A)(B) equipment shall be listed by a nationally recognized testing laboratory- x-ray, air comp, NOTE: elevator installer shall call for inspection
ELE06-02811 Final10/23/200610/24/200610/24/2006 12:38:23 PMAPASS
Scheduled by a contractor via Hello! on 10/23/2006 at 5:59:10 PM. Contact: ###-####. corr made, ok to final
ELE06-03920 Electrical Rough-In10/23/200610/24/200610/24/2006 11:09:28 AMAPART
Paul; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt west 1/2 ric ok
ELE06-02744 ELE-Aging Inspection10/24/200610/24/200610/24/2006 10:46:23 AM DONE
see final
ELE06-02744 Final10/24/200610/24/200610/24/2006 10:45:59 AMAPASS
sign uo, ok to final
ELE06-02458 Final10/23/200610/24/200610/24/2006 10:20:55 AMAPASS
This is the US Bank pole sign facing Orchard.; Phone #: ###-#### Internet Inspection Request from: Eric Shaner sign ok to final, talked to contr, elect contr said exst u/g supplied power to sign
ELE06-03399 Final10/23/200610/24/200610/24/2006 10:17:55 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Kathy Briggs ok to final
ELE06-03892 Temporary Service10/23/200610/24/200610/24/2006 9:29:45 AMAFAIL
Scheduled by a contractor via Hello! on 10/23/2006 at 3:05:53 PM. Contact: ###-####. called, left message, left corr notice, nec 250.24(B) an unspliced main bonding kumper shall be used to connect the equipment grounding conductor and the service disconnect enclosure to the grounded conductor
ELE06-03649 Permanent Service10/23/200610/24/200610/24/2006 9:02:59 AMAPASS
brandon; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok to backfill gec, p/s u/g n ok
ELE06-02801 Electrical Rough-In10/23/200610/24/200610/24/2006 8:31:07 AMAPASS
Scheduled by a contractor via Hello! on 10/23/2006 at 11:49:51 PM. Contact: ###-####. laundry room ric ok
ELE06-01785 Final10/23/200610/24/200610/24/2006 8:09:25 AMAPASS
call Brandon for entry to home; Phone #: ###-#### Internet Inspection Request from: Brandon Blackham ok to final