ELE11-02332
| Rough-In Permanent Service | 10/21/2011 | 10/24/2011 | 10/24/2011 2:49:57 PM | P | CANC |
|
|
we have a power shut down at 9 am and will do the install so we will need approval for the power to be turned back on please coordinate will corey at number above Phone #: ###-#### >> Inspection requested via web by Don Lustig contractor asked to cancel
|
ELE11-01621
| Final | 10/24/2011 | 10/24/2011 | 10/24/2011 2:36:08 PM | P | PASS |
|
|
>> Inspection requested via web by HZ ZAHIC ok final
|
ELE11-02368
| Electrical Rough-In | 10/24/2011 | 10/24/2011 | 10/24/2011 1:20:45 PM | P | FAIL |
|
|
Key under mat at front door Phone #: ###-#### >> Inspection requested via web by Therrin Robertson called, left correction notice, NEC 250.86 shall ground metal box,use ground screw, 314.23(B) shall not screw metal box to stud with screw inside box, shall rigidly mount box, 300.4 edge of nm cable shall be 1 1/4" from edge of framing member, 334.30 shall staple nm cable within 12" of panel, 300.15 shall provide boxes for termination of nm cale, 210.52(E) shall install receptacle at front of dwelling, 210.52 shall provide outlet such that no point is over 6' from outlet along floor line
|
ELE11-00845
| Final | 10/24/2011 | 10/24/2011 | 10/24/2011 12:24:34 PM | P | PASS |
|
|
pete - please call 1/2 hr prior Phone #: ###-#### ok final
|
ELE10-00081
| ELE-Aging Inspection | 10/24/2011 | 10/24/2011 | 10/24/2011 10:26:21 AM | | DONE |
|
|
still under construction
|
ELE09-00868
| ELE-Aging Inspection | 10/24/2011 | 10/24/2011 | 10/24/2011 9:43:43 AM | | DONE |
|
|
still under construction
|
ELE09-02129
| ELE-Aging Inspection | 10/24/2011 | 10/24/2011 | 10/24/2011 9:28:54 AM | | DONE |
|
|
still under construction
|
ELE11-02378
| Final | 10/21/2011 | 10/24/2011 | 10/24/2011 8:59:07 AM | A | PASS |
|
|
final on service upgrade, any questions call Jake @ ###-#### Phone #: ###-#### >> Inspection requested via web by Andy Rose ok final
|