ELE16-03416
| Electrical Rough-In | 10/20/2016 | 10/24/2016 | 10/25/2016 8:59:21 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Barbara Szurgot Checked all electrical as garage was energized. Unable to final due to all wiring exposed below 8' shall be protected from physical damage by wall cover or guard strips. Garage rough in ok cover
|
ELE16-01838
| Electrical Rough-In | 10/22/2016 | 10/24/2016 | 10/24/2016 2:11:26 PM | P | PASS |
|
|
level 1 stack 1 ceiling. call Brandon Phone #: ###-#### Inspection requested via web by Brandon Robinson Customer experience N. E corner and S. E. corner 5 rooms hardlids rough in ok cover
|
ELE16-03440
| Rough-In Permanent Service | 10/24/2016 | 10/24/2016 | 10/24/2016 1:31:41 PM | P | PASS |
|
|
Please call so I can get you in Phone #: ###-#### Inspection requested via web by Eddy Udry Rough in of permanent service only. This permit to cover trim portion of job. Contractor to cover any issue from here to completion. ELE16-00937 is permit that covers rough in portion of job. West garage has wall cover on PVC LB fittings on outside of structure, contractor to make access to LB. p/s u/g n ok
|
ELE16-03413
| Electrical Rough-In | 10/21/2016 | 10/24/2016 | 10/24/2016 10:35:18 AM | A | FAIL |
|
|
Will call Monday to fix application price on permit. Phone #: ###-#### Inspection requested via web by Charles Davis 110.3- Service riser shall be installed as per manufacterers instructions. Shall provide for rise and fall of conduit. 110.12(B)- Service riser coupling broken. 300.4- Nail plates shall protect NM cable where hole does not maintain 1 1/4" from framing surface. 45 degree corners and others. 300.15- Can over vanity secure cover on junction box. 334.12- NM cable shall not be installed where subject to physical damage. Hangs below truss in garage.
|
ELE16-00751
| Final | 10/21/2016 | 10/24/2016 | 10/24/2016 9:25:37 AM | A | PART |
|
|
units 205 209 117 123 124 129 Phone #: ###-#### Inspection requested via web by Tracy Robertson Rooms noted only exterior not complete.
|
ELE16-00752
| Final | 10/21/2016 | 10/24/2016 | 10/24/2016 9:24:49 AM | A | PART |
|
|
units 328 225 Phone #: ###-#### Inspection requested via web by Tracy Robertson Rooms noted only, exterior not complete.
|