Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-01337 Electrical Rough-In10/23/201710/24/201710/24/2017 2:17:16 PMPPASS
We are requesting a rough-in inspection for tomorrow afternoon on level 4. Our contact is Rick Badley @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate
401 thru 414, 416, 417, 418 only rough in ok cover
ELE15-00144 Final10/19/201710/24/201710/24/2017 1:28:54 PMPPASS
aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle
Final ok
ELE15-00144 Electrical Rough-In10/24/201710/24/201710/24/2017 1:28:42 PMPPASS
aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle
Listing and disconnecting means confirmed. Rough in ok
MIS17-00358 ELE-Conference10/24/201710/24/201710/24/2017 12:42:51 PMPFAIL
As per Daryl DeGrange Chief Electrical Inspector.
BCC 4-05-32 Code violations not to be retained.
210.70- Means shall be provided to disconnect all conductors in a building or structure from service entrance conductors.
210.11(C)(3)- At least one 120 volt 20 amp circuit shall be provided for bathroom receptacle outlets. This circuit shall feed no other outlets.
210.11(C)(1)- 2 or more 20 amp branch circuits shall be installed for small appliance branch circuits. These circuits shall only feed areas noted in 210.52(B).
400.12- Flexible cords shall not be used as a substitute for fixed wiring of a structure.
Dish/disp wiring and in conduit from panel.
406.4(D)- AFCI and GFCI devices shall be located in readily accessible locations for replacements.
406.4(D)(2)(b)- Non-grounding type receptacle outlets shall be permitted to be replaced grounding type receptacle outlets if GFCI protection is provided and labeled.
406.4(D)(5)- Listed tamper resistant receptacles shall be provided where replacements are made except where ungrounded type receptacles are replaced with ungrounded type receptacle outets.
ELE17-00404 Final10/19/201710/24/201710/24/2017 11:43:50 AMAPASS
Clayton Phone #: ###-####
Job reduced to bathroom only. New permit to be pulled for bedroom and mud room.
Final ok
ELE14-03017 Final10/19/201710/24/201710/24/2017 10:39:00 AMAPASS
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle Final ok
ELE14-03017 Electrical Rough-In10/24/201710/24/201710/24/2017 10:38:42 AMPPASS
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle
Listing confirmed rough in ok
ELE17-02841 Electrical Rough-In10/23/201710/24/201710/24/2017 10:24:31 AMAPASS
Rough in inspection of floor heat cable. Final inspection will be completed at time of final rough and service inspection. Phone #: ###-#### Inspection requested via web by Rowdy Monroe
Floor heat rough in ok cover
ELE17-02527 Final10/23/201710/24/201710/24/2017 10:06:18 AMAPASS
Garage cord 1242E Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
MIS17-00358 ELE-Conference10/23/201710/24/201710/23/2017 4:47:05 PMAFAIL
per Chad S-ele and plm work being done w/o permits
BCC 4-05-17- Unlawful electrical procedures. Residence owned by a real estate company and has used property as rental for years. Individual hired by them informed property has been owned by McLeod for 18 years.
Misc wiring has taken place over many years creating multiple code violations. Work shall be performed by a licenced electrical contractor with a valid electrical permit.
Dan Shawn White ELE journeyman 005497 has been assisting with some of work. He is a journeyman electrician only, no contractors license.
House has electrical service located on interior of enclosed room on back of house. Receptacles and switches have been changed out recently with grounding type receptacles on ungrounded circuits with out GFCI protection. New receptacles shall be tamper resistant type. Wiring added from bathroom GFCI receptacle to kitchen receptacles serving kitchen counter top surfaces. Bathroom receptacles shall be fed by a dedicated 20 amp circuit that shall feed no other outlets. Kitchen receptacles serving counter top surfaces shall be fed by a min of 2 20 amp branch circuits which shall only feed areas listed 210.52 (C). Flexible cords present in conduit under meter main combo and on interior of kitchen. Hood wire relocated to upper cabinet with exposed conductors. Microwave being installed shall have dedicated circuit as per 210.11.
Other violations most likely exist. Will inspect fully when electrical permit exists.
Stop work order posted