ELE17-02862
| Electrical Rough-In | 10/24/2018 | 10/24/2018 | 10/24/2018 2:24:36 PM | P | PASS |
|
|
Underground conduit for street pole lighting Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty Informed to be sure to call public works about street light installation. Idaho street west pole base and underground rough in ok cover.
|
ELE18-04108
| Electrical Rough-In | 10/24/2018 | 10/24/2018 | 10/24/2018 1:55:20 PM | P | PASS |
|
|
Ground inspection for island and floor outlets Phone #: ###-#### Inspection requested via web by Zane Robertson Underground Rough in ok cover
|
ELE18-02352
| Final | 10/24/2018 | 10/24/2018 | 10/24/2018 1:16:24 PM | P | PASS |
|
|
code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE18-04077
| Temporary Service | 10/23/2018 | 10/24/2018 | 10/24/2018 12:12:48 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE18-02581
| Final | 10/23/2018 | 10/24/2018 | 10/24/2018 11:58:22 AM | A | NR |
|
|
Garage code is 7352 enter Phone #: ###-#### Inspection requested via web by Zane Robertson House tested ok, small water feature being installed in back yard at time of inspection that shall be tested
|
ELE18-04092
| Final | 10/23/2018 | 10/24/2018 | 10/24/2018 11:17:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by steve ragan Final ok
|
ELE18-04098
| Rough-In Permanent Service | 10/24/2018 | 10/24/2018 | 10/24/2018 10:36:17 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson 110.12(A)- Unused openings shall be closed by approved means. 2" KO in bottom of meterbase. 300.4- Nail plates needed where NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface. Garage. 314.25- Recessed can junction box cover shall be installed so it totally cover opening in box. near bottom of stair back cover partailly off. 352.46- Where UF cable enters or emerges from PVC conduit it shall be protected from damage by bushings. 408.7- Unused breaker openings shall be closed by aproved means.
|
ELE18-04099
| Rough-In Permanent Service | 10/24/2018 | 10/24/2018 | 10/24/2018 10:26:34 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson 225.31- A disconnecting means shall be provided for seperate garage structure on exterior or where conductors enter structure. 300.4- Nail plates shall be installed where NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface. 300.4(B)(1)- NM cables shall be protected from damage where they enter an enclosure. Connectors shall be installed as per manufacturers instructions. Connectors not completely installed at front outdoor receptacle box, both junction boxes for garage wiring at house nad garage, service. 314.25- Recessed can junction box shall be installed to totally cover opening in box. Can at top of stair back cover partially off. 352.46- Where UF cable enters or emerges from PVC conduit it shall be protected from damage by a bushing. 408.7- Unused breaker openings shall be closed.
|
ELE18-03320
| Electrical Rough-In | 10/23/2018 | 10/24/2018 | 10/24/2018 9:03:25 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Level 5 hardlids rough in ok cover
|