ELE10-02067
| ELE-Aging Inspection | 10/25/2013 | 10/25/2013 | 10/29/2013 10:13:12 AM | | CANC |
|
|
|
ELE13-02987
| Electrical Rough-In | 10/25/2013 | 10/25/2013 | 10/25/2013 2:47:30 PM | P | FAIL |
|
|
wiring for hood with outlets on both side cut in to the existing wall (no new walls on this one) Phone #: ###-#### >> Inspection requested via web by Brad Baker called, left message, could not find hood in office building
|
ELE13-02150
| Final | 10/25/2013 | 10/25/2013 | 10/25/2013 2:27:37 PM | P | NH |
|
|
Garage door entry access 1979E. Phone #: ###-#### >> Inspection requested via web by Alan Lusk called, garage code would not work, contractor away from his phone, will recall
|
ELE13-02975
| Final | 10/24/2013 | 10/25/2013 | 10/25/2013 2:25:48 PM | P | FAIL |
|
|
Back door will be unlocked Phone #: ###-#### >> Inspection requested via web by David Nelson called contractor, summary of most NEC violations : told about bringing grounding up to code, no service conductors shall be run inside dwelling, illegal panel location in stairwell, shall provide disconnect and meter on outside of wall, can extend circuits and make old panel a junction box, circuit extensions shall be per NEC
|
ELE13-02986
| Electrical Rough-In | 10/25/2013 | 10/25/2013 | 10/25/2013 1:48:54 PM | P | PASS |
|
|
one new wall ready for cover Phone #: ###-#### >> Inspection requested via web by Brad Baker ri wall only ok
|
ELE13-02937
| Rough-In Permanent Service | 10/21/2013 | 10/25/2013 | 10/25/2013 1:22:46 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Alan Lusk ri ok, p/s u/g n ok
|
ELE13-02969
| Conference | 10/24/2013 | 10/25/2013 | 10/25/2013 12:45:03 PM | A | DONE |
|
|
PLease call Carl Pettek at ###-#### to schedule time to meet on site Friday morning. Phone #: ###-#### >> Inspection requested via web by Scott Campbell talked about re-model, split circuits for each tenant, shall get building permit, shall bring up to code within 8' of work area, no cords in ceiling, no violations shall be retained
|
ELE13-02971
| Electrical Rough-In | 10/24/2013 | 10/25/2013 | 10/25/2013 9:31:52 AM | A | PASS |
|
|
Call Jim Evans "###-####" for access information Phone #: ###-#### >> Inspection requested via web by Roy Kay ri ok bath only
|
ELE13-02977
| Electrical Rough-In | 10/24/2013 | 10/25/2013 | 10/25/2013 9:10:17 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Brad Girard ri ok main floor
|
ELE13-02795
| Electrical Rough-In | 10/25/2013 | 10/25/2013 | 10/25/2013 8:43:08 AM | A | PASS |
|
|
floor heat in bathroom, gate code *2001 Phone #: ###-#### >> Inspection requested via web by PAT MILLER ok cover floor heat
|
ELE13-02857
| Final | 10/25/2013 | 10/25/2013 | 10/25/2013 8:29:43 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by PAT MILLER ok final
|