MEC06-03561
| Final | 10/26/2006 | 10/26/2006 | 10/27/2006 8:44:31 AM | P | PASS |
|
|
|
MEC06-03554
| Final | 10/25/2006 | 10/26/2006 | 10/27/2006 8:43:57 AM | P | FAIL |
|
|
no one homef
|
MEC06-02708
| Final | 10/26/2006 | 10/26/2006 | 10/26/2006 4:01:35 PM | P | PASS |
|
|
Internet Inspection Request from: Shelley Baisch
|
MEC06-03550
| Final | 10/25/2006 | 10/26/2006 | 10/26/2006 4:01:26 PM | P | PASS |
|
|
MELODY nOTE: APT 102; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
MEC06-03571
| Pressure Test | 10/26/2006 | 10/26/2006 | 10/26/2006 3:40:19 PM | P | FAIL |
|
|
medium pressure or welded pipe has to have a 60# test
|
MEC06-03566
| Rough-in | 10/26/2006 | 10/26/2006 | 10/26/2006 3:11:05 PM | P | PASS |
|
|
Internet Inspection Request from: Shelley Baisch
|
MEC06-03212
| Final | 10/25/2006 | 10/26/2006 | 10/26/2006 2:53:07 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 10/25/2006 at 5:34:06 PM. Contact: ###-####.
|
MEC06-03501
| Final | 10/20/2006 | 10/26/2006 | 10/26/2006 2:38:35 PM | P | FAIL |
|
|
installer forgot to run t/p relief line from water heater
|
MEC06-03546
| Rough-in | 10/25/2006 | 10/26/2006 | 10/26/2006 2:07:53 PM | P | PASS |
|
|
60#
|
MEC06-03547
| Rough-in | 10/25/2006 | 10/26/2006 | 10/26/2006 2:07:28 PM | P | PASS |
|
|
60#
|
MEC06-03548
| Rough-in | 10/25/2006 | 10/26/2006 | 10/26/2006 2:07:06 PM | P | PASS |
|
|
60#
|
MEC06-03549
| Rough-in | 10/25/2006 | 10/26/2006 | 10/26/2006 2:06:40 PM | P | PASS |
|
|
60#
|
MEC06-03185
| Rough-in | 10/25/2006 | 10/26/2006 | 10/26/2006 2:06:06 PM | A | PASS |
|
|
Internet Inspection Request from: Shelley Baisch
|
MEC06-02075
| Final | 10/26/2006 | 10/26/2006 | 10/26/2006 1:27:56 PM | P | PASS |
|
|
Internet Inspection Request from: Shelley Baisch
|
MEC06-03424
| Final | 10/25/2006 | 10/26/2006 | 10/26/2006 11:58:52 AM | A | PASS |
|
|
Homeowner Merlin ###-####, any issues please call Lynn at ###-####, thank you.; Phone #: ###-#### Internet Inspection Request from: Stephanie Smith
|
MEC06-03537
| Rough-in | 10/24/2006 | 10/26/2006 | 10/26/2006 11:58:43 AM | A | PART |
|
|
two bath rooms and locker room ok and tanning area, no ceiling in any rooms yet
|
MEC06-03541
| Pressure Test | 10/24/2006 | 10/26/2006 | 10/26/2006 11:57:47 AM | A | PASS |
|
|
60# for whole system
|
MEC06-03561
| Pressure Test | 10/25/2006 | 10/26/2006 | 10/26/2006 10:59:16 AM | A | PASS |
|
|
20#
|
MEC06-03564
| Final | 10/26/2006 | 10/26/2006 | 10/26/2006 10:27:07 AM | A | PASS |
|
|
call sheryl at work and she will come home to let you in garage. Thanks; Phone #: ###-#### x3312 Internet Inspection Request from: Jon VanVleet
|
MEC06-03560
| Rough-in | 10/25/2006 | 10/26/2006 | 10/26/2006 10:01:23 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: misty evans
|
MEC06-03560
| Pressure Test | 10/25/2006 | 10/26/2006 | 10/26/2006 10:01:18 AM | A | PASS |
|
|
20#
|