Inspections for the day of: Thursday, October 26, 2006.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-02747 ELE-Aging Inspection10/26/200610/26/200610/31/2006 10:29:01 AM DONE
see final
ELE06-02746 ELE-Aging Inspection10/26/200610/26/200610/31/2006 10:28:05 AM DONE
see final
ELE06-01281 Final10/26/200610/26/200610/26/2006 3:27:59 PMPDONE
looked at signs, ok to final
ELE06-00081 Final10/26/200610/26/200610/26/2006 3:26:54 PMPPASS
looked at sign, ok to final
ELE06-03971 Electrical Rough-In10/26/200610/26/200610/26/2006 3:26:12 PMPPART
###-#### larry called, told elect about a couple 1 1/4" areas, marked on studs, kitchen, dining area, south side upper level only ok to cover, will call once wall changed for rest
ELE06-03413 Final10/26/200610/26/200610/26/2006 3:23:09 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Sean DeLacy met contr,left corr notice, nec 314.15(A) in wet locations, fittings shall be listed for use in wet locations, 110.26(A) work space about panel shall be 3' clear distance in front of panel, BCC kitchen area outlets shall operate, no violations shall be retained
ELE06-03701 Permanent Service10/26/200610/26/200610/26/2006 3:19:57 PMPFAIL
Scheduled by a contractor via Hello! on 10/26/2006 at 9:43:44 AM. Contact: ###-#### called, left corr notice, nec 110.26(A) work space height shall extend from grade to 6 1/2' above panel and shall be clear.
ELE06-03892 Temporary Service10/26/200610/26/200610/26/2006 2:40:18 PMPPASS
Scheduled by a contractor via Hello! on 10/26/2006 at 7:56:36 AM. Contact: ###-####. corr made, t/s o/h n ok
ELE06-03959 Electrical Rough-In10/25/200610/26/200610/26/2006 11:00:40 AMAPASS
Uffer ground inspection. Any questions call Mike Carter.; Phone #: ###-#### Internet Inspection Request from: David Lamarque ok to pour gec
ELE06-03687 Electrical Rough-In10/25/200610/26/200610/26/2006 10:30:32 AMAPASS
READY FOR ROUGH-IN INSPECTION FOR REGER ADDITION. THANK YOU; Phone #: ###-#### Internet Inspection Request from: Barry Kendall ric ok
ELE06-03963 Final10/25/200610/26/200610/26/2006 9:42:35 AMAPASS
Dave; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt ok to final
ELE06-03967 Permanent Service10/25/200610/26/200610/26/2006 9:22:10 AMAFAIL
inspection for moving outside meter Internet Inspection Request from: Rowdy Monroe \alled left corr notice, nec 250.53(C)(2) shall install 2 grounding electrodes, 312.5 all conductors entering enclosures shall have abrasion protection, 408.4 circuit directory shall be clear and concise, 230.24(A) service conductors shall be 8' above roof surface
ELE06-03960 Electrical Rough-In10/26/200610/26/200610/26/2006 9:01:15 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ric ok, need to see u/g before p/s, see canc
ELE06-03960 Rough-In Permanent Service10/25/200610/26/200610/26/2006 8:58:23 AMACANC
Phone #: ###-#### Internet Inspection Request from: Cathy Chiles see ri, need to see u/g before p/s , told contr to provide pot hole 2' deep to see if sweeps deep by house and garage