Inspections for the day of: Monday, October 26, 2015.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-02999 Final10/26/201510/26/201510/26/2015 3:14:59 PMPPASS
Homeowner is not home. Need to go in through back door. The dog at the residence is friendly. Phone #: ###-#### Inspection requested via web by Dan Surerus Final ok
ELE15-03426 Electrical Rough-In10/23/201510/26/201510/26/2015 2:49:06 PMPPASS
Contact is Kory ###-####. Underground inspection requested. Phone #: ###-#### Inspection requested via web by Clint Tate 3" for data only 1" for power. Underslab rough in ok cover
ELE15-03437 Rough-In Permanent Service10/26/201510/26/201510/26/2015 2:22:18 PMPFAIL
Phone #: ###-#### Inspection requested via web by Robert Schroder
Wiring not complete. kitchen counter, plant shelves.
110.14(A)- Unused openings shall be closed. Panel cover.
Called contact, unable to leave message due to mail box is full.
ELE15-03419 Electrical Rough-In10/25/201510/26/201510/26/2015 1:34:58 PMPPASS
walls Phone #: ###-#### Inspection requested via web by Bryan McLaughlin Wall rough in ok cover
ELE15-03424 Electrical Rough-In10/23/201510/26/201510/26/2015 1:00:23 PMACANC
We are requesting a rough-in for Monday 10/26/15 in the AM. Our contact for this is Trent Hammon @ ###-####. Thank you, Phone #: ###-#### Inspection requested via web by Clint Tate requested wrong permit.
ELE15-03121 Final10/23/201510/26/201510/26/2015 9:52:11 AMAPASS
Contact Ben @ ###-#### Phone #: ###-#### Inspection requested via web by Kristopher Wilson Final ok
ELE15-03435 Temporary Service10/25/201510/26/201510/26/2015 9:25:19 AMAPASS
Inspection requested via web by Brandon Hillman t/s u/g n ok
ELE15-02752 Final10/23/201510/26/201510/26/2015 9:05:04 AMAPASS
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
ELE15-02821 Final10/23/201510/26/201510/26/2015 8:24:01 AMAPASS
Code 1234 Phone #: ###-#### Inspection requested via web by Richard Gratiot Dome luminaires have compact flourescent lamps. Final ok
ELE15-03421 Final10/23/201510/26/201510/26/2015 6:27:55 AMACANC
Phone #: ###-#### Inspection requested via web by Don Conley
Needed rough in inspection
ELE15-03421 Electrical Rough-In10/26/201510/26/201510/26/2015 6:15:02 AMAPASS
Phone #: ###-#### Inspection requested via web by Don Conley discussed ths use of LFMC from box on light pole to underground. LFMC shall not be installed where subject to physical damage. Underground from light pole to sign rough in ok cover