Inspections for the day of: Thursday, October 26, 2017.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-03500 Permanent Service10/19/201710/26/201710/26/2017 1:55:11 PMPPASS
Service Upgrade from 100 to 200 Any questions please call Jordan at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller p/s u/g rec ok
ELE17-03485 Permanent Service10/26/201710/26/201710/26/2017 1:52:35 PMPPASS
Troy Phone #: ###-#### p/s o/h rec ok. GEC is run under mandoor thresh hold. Contractor sleeved with emt for protection
ELE17-03476 Final10/26/201710/26/201710/26/2017 1:16:31 PMPPASS
Carl Phone #: ###-#### Ok final.
ELE17-02915 Final10/25/201710/26/201710/26/2017 1:10:05 PMPPASS
Mini split is future only. Phone #: ###-#### Inspection requested via web by Alan Lusk Ok final. Disconnect fed with 12/2 for future mini split.
ELE17-03000 Final10/25/201710/26/201710/26/2017 12:59:19 PMPPASS
Final Solar Array Phone #: ###-#### Inspection requested via web by Paula Gietzen Ok final. All labeling present,
ELE17-03624 Electrical Rough-In10/26/201710/26/201710/26/2017 12:42:32 PMPPASS
Contact Jason Noble - underground inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden OK cover. 2 grd rods in trench 6' apart at a depth of 36"
ELE17-03616 Temporary Service10/26/201710/26/201710/26/2017 11:52:02 AMPPASS
Phone #: ###-#### Inspection requested via web by Dan Rohl t/s u/g n ok
ELE17-02326 Final10/25/201710/26/201710/26/2017 10:30:42 AMAPASS
The homeowner is home all the time. Drew is contact ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clay Morgan Ok final.
ELE17-03525 Electrical Rough-In10/25/201710/26/201710/26/2017 10:12:35 AMAPASS
It is a new garage so it is open. If you have any questions please call Tony ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clay Morgan Ok cover.
ELE17-03219 Electrical Rough-In10/25/201710/26/201710/26/2017 10:12:11 AMAPASS
ug conduit Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Ok cover conduit at depth atleast 20"
ELE17-03602 Conference10/25/201710/26/201710/26/2017 10:11:33 AMADONE
rebar - Chuck Phone #: ###-#### Discussed perimeter bond. 18"-24" out from waters edge, and 4" minimum to 6" maximum below finished grade for burial depth. #8 solid copper needs to be used.
ELE17-03556 Final10/25/201710/26/201710/26/2017 10:08:40 AMAPASS
Please contact Dylan with any questions at ###-#### Phone #: ###-#### Inspection requested via web by Darren Larsen Ok final.
ELE17-03611 Electrical Rough-In10/25/201710/26/201710/26/2017 8:56:14 AMAPASS
Phone #: ###-#### Inspection requested via web by TOM BICANDI Ok cover.
ELE17-03554 Electrical Rough-In10/25/201710/26/201710/26/2017 8:42:40 AMAPASS
Call Steve when in route if possible. Phone #: ###-#### Inspection requested via web by Steve McCloy Ok cover. Multiple locations on 2nd floor. No room numbers to list. Will need Steve on site for final to cover all areas.