Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-04137 Electrical Rough-In10/26/201810/26/201810/26/2018 4:43:10 PMPFAIL
Underground - Scott Phone #: ###-####
250.32- Equipment grounding conductor shall be installed where additional metallic connection exists to seperate building.
ELE18-04137 Conference10/26/201810/26/201810/26/2018 4:34:16 PMPPASS
Underground - Scott Phone #: ###-####
Discussed underground, type of receptacles in garage, 4 wire to seperate structure with metallic connections between, required bathroom circuits and receptacle locations, receptacle layout for kitchen and habitable room. Pamphlet given.
ELE18-02479 Final10/26/201810/26/201810/26/2018 3:39:24 PMPFAIL
Temporary Occupancy Inspection at the One Cap building level 10 ; 12.
Contact Jon Novak
Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek
Level 10 electrical contractor had not energized circuits for receptacles and furniture at time of inspection.
300.15- All wiring shall terminate in a box. Several sections of furniture still need connected to building wiring.
406.6- Receptacles shall be securely mounted to a box and covers in place. Tile being installed in break area, receptacles have been removed from boxes and hanging on wiring.
330.12- MC cable shall not be installed where subject to physical damage. Stubs to furniture along widow walls exposed on window frame and enter lower wall. Shall be installed in a protective conduit or channel.
Unable to test this floor.
Level 12 same as 10 unable to test.
If contractor requests I offered to come in on Sunday to inspect. Informed contact must be made to building official and additional fee paid.
ELE18-01206 Electrical Rough-In10/26/201810/26/201810/26/2018 1:52:14 PMPPART
Please call Bobby for inspection of ceiling grid in area A of third floor and for R/I inspection of walls on 3rd floor area C. Thanks! Phone #: ###-#### Inspection requested via web by Rafael Castillo
Checked electrical rooms on level 3. Informed panic hardware required prior to energizing.
No walls in area C level 3 were inspected.
Level 3 area A grid only rough in ok after temp wiring has been removed.
ELE18-02559 Electrical Rough-In10/26/201810/26/201810/26/2018 1:48:58 PMAPASS
Please call Gary for R/I inspection of walls in servery. Thanks! Phone #: ###-#### Inspection requested via web by Rafael Castillo No columns, or hardlids. Walls only servery rough in ok cover
ELE18-03949 Rough-In Permanent Service10/25/201810/26/201810/26/2018 11:44:13 AMAPASS
Phone #: ###-#### Inspection requested via web by Rowdy Monroe
Rough in ok cover p/s u/g n ok
ELE18-04132 Final10/25/201810/26/201810/26/2018 11:09:22 AMAPASS
Call ahead // UFER insp // David Phone #: ###-#### Final ok
ELE18-04132 Electrical Rough-In10/26/201810/26/201810/26/2018 11:08:59 AMPPASS
Call ahead // UFER insp // David Phone #: ###-####
Permit for concrete encased electrode only. Adding concrete encased electrode after foundation pour complete. Installed on top of footing rough in ok cover
ELE18-03942 Rough-In Permanent Service10/25/201810/26/201810/26/2018 10:52:36 AMAFAIL
Phone #: ###-#### Inspection requested via web by Bob Glenn
110.7- Installations shall be complete. Empty light box in garage ceiling.
340.10(4)- UF shall comply with 334. 334.30 UF shall be secured with in 12" of entering PVC to island.
352.28- Cut ends of PVC shall have rough edges removed.
352.46- Where UF enter or emerges from PVC they shall be protected from damage by bushings.
ELE18-02542 Final10/25/201810/26/201810/26/2018 9:58:49 AMANH
Corbin ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg
No answer at door. Owner stated living in basement on previous inspection. Due to residence occupied someone must be home fro entry.
ELE18-03762 Final10/25/201810/26/201810/26/2018 9:25:47 AMAFAIL
Contact Lance if space is locked up
208.703.2035 Phone #: ###-#### Inspection requested via web by David Feller 404.9- All swich covers shall be installed.
406.6- All receptacles covers shall be installed.
404.9