Inspections for the day of: Friday, October 26, 2018.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM18-02764 Plumbing Rough-in10/23/201810/26/201810/26/2018 4:55:07 PMANR
PHIL IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER rescheduled for monday
PLM17-03716 Final10/26/201810/26/201810/26/2018 4:53:58 PMPFAIL
Mike Phone #: ###-####
The T&p cannot be connected with a flex connector.
PLM18-04424 Plumbing Rough-in10/26/201810/26/201810/26/2018 4:41:16 PMPPASS
Phone #: ###-#### Inspection requested via web by Troy Pherigo
PLM18-04443 Final10/22/201810/26/201810/26/2018 4:26:55 PMPPEND
Please call Jason to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg
contractor to reschedule
PLM18-04312 Water and/or Sewer10/25/201810/26/201810/26/2018 4:18:01 PMPFAIL
The hose clamps on the water service must be opposed

Install a cleanout on the sewer
PLM18-04309 Water and/or Sewer10/25/201810/26/201810/26/2018 4:14:37 PMPPASS
late
PLM18-04309 DOC - Permit Finaled10/26/201810/26/201810/26/2018 4:14:25 PMPPASS
PLM18-04540 Water and/or Sewer10/26/201810/26/201810/26/2018 3:54:15 PMPPART
Underground - Scott Phone #: ###-####
Put sewer under test and add a tracer wire on the water line
PLM18-02415 Final10/25/201810/26/201810/26/2018 11:52:47 AMAPASS
Phone #: ###-#### Inspection requested via web by Robert Frazier
PLM18-04533 Water and/or Sewer10/26/201810/26/201810/26/2018 11:35:32 AMPPASS
This is at the Shari''s on Franklin. Phone #: ###-#### Inspection requested via web by Lynn Mallory
PLM18-04533 DOC - Permit Finaled10/26/201810/26/201810/26/2018 11:35:23 AMPPASS
PLM18-04512 Groundwork10/25/201810/26/201810/26/2018 11:12:36 AMAPASS
Fry St is the best way to come into the job Beverly St is closed Phone #: ###-#### Inspection requested via web by RM Mechanical
PLM18-04520 Groundwork10/25/201810/26/201810/26/2018 11:01:25 AMAPASS
Phone #: ###-#### Inspection requested via web by Nels Moore
PLM18-04521 Pressure Test10/25/201810/26/201810/26/2018 11:01:12 AMAPASS
Phone #: ###-#### Inspection requested via web by Nels Moore 60# ok
PLM18-03015 Final10/24/201810/26/201810/26/2018 10:29:03 AMAPASS
Please call Marilyn Watkins prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
PLM18-04493 Groundwork10/25/201810/26/201810/26/2018 10:13:22 AMAPASS
Inspection requested via web by Sharon Afinson
PLM17-04243 PLM-Aging Inspection10/26/201810/26/201810/26/2018 10:01:41 AM NR
PLM18-04517 Plumbing Rough-in10/25/201810/26/201810/26/2018 9:59:07 AMAPASS
As early as possible and please call half hour before // Ken Phone #: ###-####
PLM18-02963 Final10/25/201810/26/201810/25/2018 2:04:40 PMAPASS
Please give our technician Kyle a call with any questions. Thank you! Phone #: ###-#### Inspection requested via web by Ben Davis
Picture of the drip-leg received.