ELE11-00646
| ELE-Aging Inspection | 10/27/2011 | 10/27/2011 | 10/31/2011 3:07:25 PM | | DONE |
|
|
see final
|
ELE11-02145
| Final | 10/27/2011 | 10/27/2011 | 10/28/2011 10:15:04 AM | P | DONE |
|
|
inspection on wiring of new heat pump, any questions call Jake @ ###-####, please call Letha @ ###-#### for access to house. Phone #: ###-#### >> Inspection requested via web by Andy Rose see 315 response 10/28/11
|
ELE11-02449
| Rough-In Permanent Service | 10/27/2011 | 10/27/2011 | 10/27/2011 3:49:10 PM | P | FAIL |
|
|
Ed Phone #: ###-#### called, 6" free conductor length, shall staple nm 12" over panel, shall add nail plates, shall repair damaged jacket for nm cable,shall verify available fault current, shall post job id sticker
|
ELE11-02445
| Electrical Rough-In | 10/27/2011 | 10/27/2011 | 10/27/2011 3:07:05 PM | P | NH |
|
|
Phone #: ###-#### >> Inspection requested via web by mike brown called, will recall
|
ELE11-02368
| Electrical Rough-In | 10/27/2011 | 10/27/2011 | 10/27/2011 1:52:27 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson corrections made, ri ok
|
ELE11-02381
| Permanent Service | 10/27/2011 | 10/27/2011 | 10/27/2011 1:03:25 PM | A | PASS |
|
|
Reinspect after supplemental grounding installed. After power is connected, will label panel and call for final as per Bob''s request. For access, there is a lock box on shed of property. Access code is ARL. Call with any questions or concerns. Thanks, Eric Phone #: ###-#### >> Inspection requested via web by Eric Schroeder corrections made p/s o/h rec ok
|
ELE11-02409
| Electrical Rough-In | 10/27/2011 | 10/27/2011 | 10/27/2011 12:41:48 PM | P | PASS |
|
|
corey - wall cover Phone #: ###-#### walls only ok cover , left sticker, see 10-24-11-response also
|
ELE11-02432
| Rough-In Permanent Service | 10/27/2011 | 10/27/2011 | 10/27/2011 12:27:42 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman ri both sides ok, p/s u/g n ok, 2 meters req'd
|
ELE11-02287
| Final | 10/26/2011 | 10/27/2011 | 10/27/2011 10:43:45 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Zane Robertson ok final, no card to sign
|
ELE11-02121
| Final | 10/27/2011 | 10/27/2011 | 10/27/2011 10:30:03 AM | A | FAIL |
|
|
Please call Jeff If you have any questions. Thanks Phone #: ###-#### >> Inspection requested via web by Brandon Blackham called, shall fix 3-way light switch in laundry room, add per NEC 210.52 receptacle in north wall of kitchen, rest ok
|
ELE11-02441
| Electrical Rough-In | 10/26/2011 | 10/27/2011 | 10/27/2011 9:50:28 AM | A | CANC |
|
|
Electrician Larry Phone #: ###-#### >> Inspection requested via web by Dave Koeppen see response for rip
|
ELE11-02441
| Rough-In Permanent Service | 10/26/2011 | 10/27/2011 | 10/27/2011 9:48:18 AM | A | FAIL |
|
|
Electrician Larry Phone #: ###-#### >> Inspection requested via web by Dave Koeppen called, NEC 334.23 shall protect cables within 6' of attic access, 240.24(A) center of operating handle shall not be over 6'-7" above floor, BCC shall provide boxes for all nm cable
|
ELE11-02439
| Electrical Rough-In | 10/26/2011 | 10/27/2011 | 10/27/2011 9:14:14 AM | A | PASS |
|
|
Just took some switches out of bathrooms in common area. Door will be open and just look for the bathrooms, it isn''t a big area. CJ in contact. Thank you Phone #: ###-#### >> Inspection requested via web by Chris Chesnut ri ok baths only
|
ELE11-02430
| Final | 10/26/2011 | 10/27/2011 | 10/27/2011 8:53:47 AM | A | FAIL |
|
|
This will be a final for a lighting retrofit. Contact is Bob Callahan. Thank you and have a super day! Phone #: ###-#### >> Inspection requested via web by Laura Longshaw met contractor, NEC 400.5 shall not use so cord for permanent wiring for fixtures
|
ELE11-02394
| Permanent Service | 10/26/2011 | 10/27/2011 | 10/27/2011 8:24:49 AM | A | DONE |
|
|
Charlie Phone #: ###-#### service ok per contractor permit 10-26-11, called owner
|
ELE11-02419
| Rough-In Permanent Service | 10/27/2011 | 10/27/2011 | 10/27/2011 8:18:43 AM | A | PASS |
|
|
THANKS, BILL Phone #: ###-#### >> Inspection requested via web by Bob Glenn ri ok, p/s u/g n ok
|
ELE10-02808
| ELE-Aging Inspection | 10/27/2011 | 10/27/2011 | 10/27/2011 6:28:09 AM | | DONE |
|
|
still under construction
|