ELE12-00736
| ELE-Aging Inspection | 10/27/2015 | 10/27/2015 | 10/28/2015 10:59:33 AM | | DONE |
|
|
too busy
|
ELE13-00565
| ELE-Aging Inspection | 10/27/2015 | 10/27/2015 | 10/28/2015 10:59:00 AM | | DONE |
|
|
too busy
|
ELE15-03465
| Electrical Rough-In | 10/27/2015 | 10/27/2015 | 10/27/2015 4:17:03 PM | P | PASS |
|
|
please contact garrett bailey for access into building - ###-#### Phone #: ###-#### Inspection requested via web by Cyndi Dale r/i walls shown on floor plan print ok
|
ELE15-02378
| Conference | 10/26/2015 | 10/27/2015 | 10/27/2015 3:44:52 PM | P | DONE |
|
|
Vince Phone #: ###-#### discuss residential codes for addition . sub panel being installed in "hot" wall needs fire barrier. They will confirm with bldg. inspector . discuss recep. spacing, circuits required, Keep dedicated circuit to garage, bathroom arc fault for bdrm, etc
|
ELE15-03278
| Temporary Service | 10/27/2015 | 10/27/2015 | 10/27/2015 2:44:07 PM | P | PASS |
|
|
Need inspection for temp. pole to re feed house during addition construction Phone #: ###-#### Inspection requested via web by Andy Rose t/s o/h n ok
|
ELE15-03440
| Permanent Service | 10/26/2015 | 10/27/2015 | 10/27/2015 2:35:45 PM | P | PASS |
|
|
Plan is to energize new service, then do change-over and call for final. Main ground is ran to inside basement to where water line enters house. Garage living space has plastic plumbing. Please call if any questions. Phone #: ###-#### Inspection requested via web by Troy Cobb p/s o/h rec ok Note:underground to garage and grounding electrode to garage ok to cover. 2 ground rods take care of service and sub panel on garage
|
ELE15-02717
| Final | 10/23/2015 | 10/27/2015 | 10/27/2015 2:13:49 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by SHAWN TOMLINSON remove abandoned conduit and wiring 408.7-filler plates required in unused openings of panel. 110.16-Arc flash warning labels required on all panels. 300.15-Remove abandoned conduit and wire. 330.30- MC type cable shall be secured and supported within 12" of enclosure and every 6' thereafter. 408.4(A)- circuit directory required for loads served in panels. Ceilings tiles installed prior to inspection need to be removed.
|
GCE15-00161
| GCE-Rough-In Permanent Service | 10/27/2015 | 10/27/2015 | 10/27/2015 1:17:38 PM | A | PASS |
|
|
r/i ok p/s u/g n ok
|
ELE15-03137
| Final | 10/27/2015 | 10/27/2015 | 10/27/2015 11:53:15 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jim Williams corrections made area classification changed to regular garage. final ok
|
ELE15-02740
| Conference | 10/26/2015 | 10/27/2015 | 10/27/2015 11:19:41 AM | A | DONE |
|
|
Jacob Phone #: ###-#### ct enclosure ok on xformer and main disconnect in MSB ok in locked electrical room with NOX box for EMS and door labeled "electric room", all ok as per plans
|
ELE15-03431
| Electrical Rough-In | 10/26/2015 | 10/27/2015 | 10/27/2015 10:55:15 AM | A | PASS |
|
|
ceiling; Jose Phone #: ###-#### r/i grid ceiling ok
|
ELE15-03416
| Electrical Rough-In | 10/26/2015 | 10/27/2015 | 10/27/2015 10:20:38 AM | A | PASS |
|
|
walls ; hard ceilings Phone #: ###-#### Inspection requested via web by Lee VanSchoiack r/i walls and hard lids ok NOTE:edge of sink near loadcenter shall be at least 36" away from loadcenter as per Boise city ordinance 4-05-31(A) and AHJ. A barrier will be installed as per general contractor and will maintain 30" clearance UNIT ADDRESS SAYS139??
|
ELE15-01702
| Final | 10/26/2015 | 10/27/2015 | 10/27/2015 9:04:54 AM | A | PASS |
|
|
Before you go call Braden at ###-#### and he will let you in. Phone #: ###-#### Inspection requested via web by George Pascua final ok
|
ELE15-03097
| Electrical Rough-In | 10/26/2015 | 10/27/2015 | 10/27/2015 8:30:12 AM | A | PASS |
|
|
There is a lockbox code is 2265, if you have any questions, please give Mike a call at ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan r/i upst. and dnst. and garage ok
|
ELE15-03776
| Temporary Service | 10/27/2015 | 10/27/2015 | 10/27/2015 12:00:00 AM | A | PASS |
|
|
the temp pole was inspected under ele15-03278
|
GCE15-00162
| GCE-Rough-In Permanent Service | 10/28/2015 | 10/27/2015 | 10/27/2015 12:00:00 AM | P | PASS |
|
|
David ###-#### already inspected and passed on 10/27
|