ELE17-03643
| Electrical Rough-In | 10/27/2017 | 10/27/2017 | 10/27/2017 3:04:59 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Don Conley Detached garage rough in ok cover
|
ELE17-00739
| Final | 10/27/2017 | 10/27/2017 | 10/27/2017 2:42:06 PM | P | PASS |
|
|
Please contact Sid with any questions or concerns ###-####
Thank you and have a nice weekend! Phone #: ###-#### Inspection requested via web by JENNY EMEL Final ok
|
ELE17-03473
| Electrical Rough-In | 10/25/2017 | 10/27/2017 | 10/27/2017 1:30:03 PM | P | PART |
|
|
Please call Tom with any questions. Phone #: ###-#### Inspection requested via web by Kevin Perez Must allow time to move home runs to basement for new panel location. Main floor only rough in ok cover
|
ELE14-00774
| Final | 10/26/2017 | 10/27/2017 | 10/27/2017 12:20:29 PM | A | NR |
|
|
Please call Alisha prior to gain access, her no. is ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates Called contact for access and she stated job is not ready and would reschedule.
|
ELE17-02009
| Final | 10/26/2017 | 10/27/2017 | 10/27/2017 12:13:04 PM | A | FAIL |
|
|
Ron Phone #: ###-#### 200.7(C)(1)- White conductor used for other than grounded conductor shall be re-identified. AC ungrounded conductor. 210.8- All GFCI devices shall be installed in a readily accessible location. Garage door GFI. 210.8(A)(5)- Receptacles outlets installed in unfinished areas shall have GFCI protection. Garage loft. 210.11(C)(3)- All receptacle outets installed in bathroom locations shall be on a 20 amp circuit. Powder bath 12ga installed on a 15 amp breaker. 210.63- A receptacle outlet shall be installed with in 25' of outdoor HVAC equipment. 210.70(A)(2)- Required lighting outlet located at garage lower man door not working. (Bulbs) 334.15(B)- Horizontal runs of NM cable in garage loft shall be protected from physical damage due to area unfinished. 422.31- A disconnecting means shall be provided for permenantly installed hood. 110.25 lockout acceptable.
|
ELE17-02778
| Final | 10/27/2017 | 10/27/2017 | 10/27/2017 10:06:35 AM | A | PASS |
|
|
4224 code Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE17-02653
| Final | 10/27/2017 | 10/27/2017 | 10/27/2017 10:00:26 AM | A | PASS |
|
|
4224 code Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE17-02779
| Final | 10/27/2017 | 10/27/2017 | 10/27/2017 9:59:59 AM | A | PASS |
|
|
4224 code Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE17-03623
| Temporary Service | 10/26/2017 | 10/27/2017 | 10/27/2017 9:18:26 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by caleb Larson t/s u/g n ok
|