Inspections for the day of: Friday, October 27, 2017.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-02398 Final10/27/201710/27/201710/27/2017 1:56:05 PMPPASS
Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Ok final.
ELE14-03436 Final10/27/201710/27/201710/27/2017 1:32:15 PMPPASS
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle Ok final. All sigen componets UL listed. Disconnect located on power supply in ceiling upon entry of business.
ELE17-02737 Final10/24/201710/27/201710/27/2017 1:13:28 PMPPASS
Please Call Leslie on your way to meet you ###-####, she will need about a 20 minute heads up. If you have any questions please feel free to call Aaron ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clay Morgan Ok final.
ELE17-03636 Electrical Rough-In10/26/201710/27/201710/27/2017 1:06:45 PMPPASS
Phone #: ###-#### Inspection requested via web by Andy Derrick Ok cover cans in down living ceiling
ELE17-03500 Final10/26/201710/27/201710/27/2017 12:44:45 PMAFAIL
Any questions please call Jordan at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller Ornamental metal hoops extending from down spouts of gutter need to be removed. Any metal withing 5' of waters edge needs to be bonded or removed.
ELE17-03639 Conference10/27/201710/27/201710/27/2017 12:30:16 PMPDONE
Phone #: ###-#### Inspection requested via web by Don Conley Discussed running mast up through roof. Where existing mast now is within 3 ft of new window opening. Mast through roof will end up being about 40". It will be code compliant as far as the 5/12 ptich requirements. And only about 4-1/2 to 5 ft on conductors will pass over the roof which is less than the 6' required by code.
ELE17-03087 Electrical Rough-In10/26/201710/27/201710/27/2017 11:41:17 AMPPASS
RI FOR 2 WALLS AND CAN LIGHTS. Phone #: ###-#### Inspection requested via web by Garrett Collins Ok cover S wall playroom, S 2 walls living and cans throughout.
ELE17-02925 Rough-In Permanent Service10/26/201710/27/201710/27/2017 10:10:12 AMACANC
service entrance conduits and grounding for backfill at building Phone #: ###-#### Inspection requested via web by Karl Paige Permanent service only, no RI.
ELE17-02925 Permanent Service10/27/201710/27/201710/27/2017 10:09:46 AMPPASS
p/s u/g n ok
ELE17-03622 Electrical Rough-In10/26/201710/27/201710/27/2017 10:00:49 AMAPASS
Owner will be home, Donna Smiley, ###-#### is her number and I should be there by 10:00. Wiring in shop and underground from house to shop. Please call if you have any questions, Thank you. Phone #: ###-#### Inspection requested via web by Rick Beckman Ok cover grd work and shop. Outlets and lights ran in MC. All metal boxes have grd screws.
ELE17-03337 Final10/25/201710/27/201710/27/2017 9:54:21 AMAPASS
call 20 min befor to meet // (parcel owner) Hillary Deeds Phone #: ###-#### Ok final. Labels present, 40a 2 pole, #8 wire.
ELE17-02628 Final10/26/201710/27/201710/27/2017 9:25:53 AMAPASS
Have a good day call me if there is any problems. Phone #: ###-#### Inspection requested via web by Cindie Swaim Ok final.
ELE17-03200 Electrical Rough-In10/26/201710/27/201710/27/2017 9:11:52 AMAPASS
Phone #: ###-#### Inspection requested via web by Dean Gernaat Ok cover. Corrections made.
ELE17-03584 Permanent Service10/26/201710/27/201710/27/2017 8:55:13 AMAPASS
Phone #: ###-#### Inspection requested via web by William Andrews p/s o/h n ok. 2 grd rods on back side of house, also Intersystem present.
ELE17-03578 Electrical Rough-In10/27/201710/27/201710/27/2017 8:38:22 AMAPASS
Please give me half an hour notice before inspection to insure access. Thank you Shaun ###-#### Phone #: ###-#### Inspection requested via web by Shaun Kirkman Ok cover. Kitchen and PF in living with cans.