Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM17-03043 Final10/26/201710/27/201710/27/2017 5:45:26 PMPFAIL
Phone #: ###-#### Inspection requested via web by Jason Adams.
1. Install a tempering valve on the water heater or all public sinks.
2. The t&p on the water heater is backgrading.
3. The backflow needs to be cerified.
4. The access to the backflow must be big enough to get to the unions for removal and service.
PLM17-00002 PLM-Aging Inspection10/27/201710/27/201710/27/2017 5:13:30 PM FAIL
1. The t&p drain is backgrading.
2. Install a tempering valve on the water heater or at all public sinks.
3. The backflow needs to be certified.
4. The access to the backflow needs to be large enough to access the unions on the pipes for replacement and repair.
PLM17-04090 Water Heater Final10/23/201710/27/201710/27/2017 3:47:26 PMPPASS
JOE SHAW REQUESTED AS LATE IN THE AFTERNOON AS YOU HAVE. PLEASE CALL HIM ###-#### WHEN YOU ARE ON YOUR WAY. THANK YOU. Phone #: ###-#### Inspection requested via web by JEREMY LINK
PLM17-03952 Groundwork10/27/201710/27/201710/27/2017 3:28:06 PMPFAIL
The 4" wyes at the foundation wall are backgrading. Check the wyes by the correction notice.
PLM17-03873 Plumbing Rough-in10/26/201710/27/201710/27/2017 3:09:54 PMPPASS
RILEY IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER. Adding an air hammer arrestor. Check on trim
PLM17-04161 Other10/27/201710/27/201710/27/2017 2:48:59 PMPFAIL
Started 24hr test on the grease interceptor. Notified the contractor that the tank is leaking.
PLM17-03093 Groundwork10/27/201710/27/201710/27/2017 2:14:18 PMPCANC
It is ready for inspection so if you would like to get there early its fine Phone #: ###-#### Inspection requested via web by Brian Johansen.
Groundwork already done
PLM17-03675 Groundwork10/27/201710/27/201710/27/2017 2:13:51 PMPCANC
is ready so if you would like to it can be an am inspection Phone #: ###-#### Inspection requested via web by Brian Johansen.
Groundwork already done
PLM17-04070 Plumbing Rough-in10/26/201710/27/201710/27/2017 1:51:51 PMPPASS
Phone #: ###-#### Inspection requested via web by Brian Johansen
PLM17-04097 Final10/26/201710/27/201710/27/2017 11:51:51 AMAPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
PLM17-04188 Plumbing Rough-in10/26/201710/27/201710/27/2017 11:32:23 AMAPART
It is rough in/finish
Go thru main doors. Left and go wet towards bathrooms. you will be able to see plumbing. I will let them know to expect you and to watch for you.
Scott Phone #: ###-#### Inspection requested via web by Scott Myers.
R-in ok. Need to add a tempering vavle to the hand sink faucet and reconnect all plumbing
PLM17-03415 Final10/24/201710/27/201710/27/2017 10:49:30 AMANR
Please inspect late AM. We are doing a mechanical inspection also Phone #: ###-#### Inspection requested via web by Mary LaFayette
PLM17-04160 Final10/26/201710/27/201710/27/2017 10:38:43 AMAPASS
please call John ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
PLM17-03952 Groundwork10/26/201710/27/201710/27/2017 10:20:21 AMAPART
Phone #: ###-#### Inspection requested via web by Dennis Seward..
Fittings ok. Need backfill or stake pipe for grade and support
PLM17-03787 Groundwork10/27/201710/27/201710/27/2017 9:51:11 AMAPASS
Grease lines and water service pressure test.
PLM17-03787 Water and/or Sewer10/26/201710/27/201710/27/2017 9:50:36 AMACANC
Inspect grease and water
8018592622 Phone #: ###-#### Inspection requested via web by Benjamin Naylor
PLM17-04056 Sprinkler (Final)10/26/201710/27/201710/27/2017 9:29:48 AMAPASS
PLM17-01218 PLM-Aging Inspection10/27/201710/27/201710/27/2017 8:33:41 AM PASS
PLM17-01218 DOC - Permit Finaled10/27/201710/27/201710/27/2017 8:33:31 AMPPASS
PLM17-02643 Plumbing Rough-in10/26/201710/27/201710/27/2017 8:19:25 AMPCANC
Contact: Robert Church ###-#### Phone #: ###-#### >> Inspection requested via web by Brent Lacy Inspection cancelled from web by: Brent Lacy