Inspections for the day of: Tuesday, October 28, 2008.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC08-00802 General Inspection10/28/200810/28/200810/28/2008 5:05:19 PMPPASS
looked ok
ESC07-01453 General Inspection10/28/200810/28/200810/28/2008 3:51:38 PMAPASS
looked ok
ESC08-00504 General Inspection10/28/200810/28/200810/28/2008 3:34:27 PMAPASS
looked ok
ELE08-02912 Electrical Rough-In10/28/200810/28/200810/28/2008 3:10:48 PMPFAIL
harvey Phone #: ###-#### called, left correction notice, NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 210.52 (A) shall provide receptacle in 2' wall by entry door
ELE08-02534 Electrical Rough-In10/28/200810/28/200810/28/2008 2:13:39 PMPFAIL
This inspection will be for a partial cieling. Contact is Mark Hood. Thank you and have a grea day Phone #: ###-#### Internet Inspection Request from: Laura Longshawn met electrician, left correction notice, BCC no violations shall be retained, NEC 300.11(B) wiring in ceiling shall not be supported by ceiling or its support wires (low voltage), 110.26 sufficient work space shall be provide about electricqal equipment (panel in ceiling), 725.25 abandoned cable shall be removed, no esc this project
ELE08-02915 Electrical Rough-In10/28/200810/28/200810/28/2008 1:17:52 PMPPART
Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton 2 south east existing rooms only ok to cover, no esc this project
ELE08-01632 Rough-In Permanent Service10/27/200810/28/200810/28/2008 10:43:51 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Jenni Keller corrections made, ric ok, p/s, u/g, n, ok
ELE08-02897 Conference10/24/200810/28/200810/28/2008 9:27:02 AMADONE
Patrick Phone #: ###-#### met owner, told him he needs to provide concrete encased electrode, outside door light, strap for rnc below panel, nail plates, and to call for ri when ready
ELE08-02909 Temporary Service10/27/200810/28/200810/28/2008 8:23:09 AMAPASS
TEMP POWER POLE CONTACT JACK Phone #: ###-#### Internet Inspection Request from: Emmet Bushman t/s u/g n ok, no esc this permit
ESC08-00825 General Inspection10/28/200810/28/200810/28/2008 4:57:24 AMPPASS
looked ok
ESC08-00361 General Inspection10/28/200810/28/200810/28/2008 4:56:24 AMPPASS
looked ok
ESC06-01299 General Inspection10/28/200810/28/200810/28/2008 4:55:28 AMPPASS
looked ok