ELE12-00736
| ELE-Aging Inspection | 10/28/2014 | 10/28/2014 | 11/3/2014 1:48:56 PM | | DONE |
|
|
Waiting on owner
|
ELE14-02973
| Final | 10/28/2014 | 10/28/2014 | 10/28/2014 3:49:40 PM | P | PASS |
|
|
Late afternoon if possible. THank you. Phone #: ###-#### Inspection requested via web by Randy Fletcher Final ok
|
ELE14-02994
| Electrical Rough-In | 10/27/2014 | 10/28/2014 | 10/28/2014 3:26:38 PM | P | PASS |
|
|
Contact Travis Hust Phone #: ###-#### Inspection requested via web by Tom Betty underground for service and 2 spare out of building rough in ok cover
|
ELE14-02965
| Electrical Rough-In | 10/28/2014 | 10/28/2014 | 10/28/2014 3:06:33 PM | P | PART |
|
|
Josh Phone #: ###-#### House not ready for inspection. Underground conduit from pole to house service location rough in ok cover
|
ELE14-02965
| Conference | 10/28/2014 | 10/28/2014 | 10/28/2014 3:05:02 PM | P | DONE |
|
|
Josh Phone #: ###-#### Discussed rewiring of 4 rooms on main floor. Minimum 2 20 amp circuit serving counter top space in kitchens, dedicated 20 amp for bath recepticals, outlet spacing for habitable rooms.
|
ELE14-00968
| Electrical Rough-In | 10/28/2014 | 10/28/2014 | 10/28/2014 2:14:16 PM | P | PASS |
|
|
Need an ok to cover new walls. call Alan the home owner @###-#### prior to arrival to gain entry. Call Jimmy @ ###-#### for questions. Phone #: ###-#### Inspection requested via web by John Edwards Contractor to add bed bath, closet and floor heat to permit. Wall and ceiling rough in ok cover
|
ELE14-02388
| Final | 10/28/2014 | 10/28/2014 | 10/28/2014 1:42:16 PM | P | PASS |
|
|
Ken Phone #: ###-####-all primary powers by others UL listing and disconnecting means confirmed Final ok
|
ELE14-02388
| Electrical Rough-In | 10/28/2014 | 10/28/2014 | 10/28/2014 1:41:59 PM | P | PASS |
|
|
Ken Phone #: ###-####-all primary powers by others Sign electrical feeders existing from previous sign. Rough in ok
|
ELE14-02539
| Final | 10/28/2014 | 10/28/2014 | 10/28/2014 1:17:10 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by steve ragan Permit for disconnect, step down transformer and 120,240 volt panel. Branch circuits to installed at future date on seperate permit. Final ok
|
ELE14-02974
| Final | 10/28/2014 | 10/28/2014 | 10/28/2014 12:47:21 PM | P | PASS |
|
|
Call for access code upon arrival. Phone #: ###-#### Inspection requested via web by Patrick Paz Final ok
|
ELE14-03013
| Final | 10/28/2014 | 10/28/2014 | 10/28/2014 12:37:43 PM | P | PASS |
|
|
Chris is contact. Thanks Phone #: ###-#### Inspection requested via web by Chris Chesnut Final ok
|
ELE14-02837
| Electrical Rough-In | 10/28/2014 | 10/28/2014 | 10/28/2014 12:15:05 PM | P | PASS |
|
|
I just need a burial depth inspection for the conduit ran from the house to the detached garage, please call for any questions, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren Discussed wiring on house 2nd story being added, existing panel location over stair will check on future rough in access to move panel. Underground to garage rough in ok cover
|
ELE14-02992
| Electrical Rough-In | 10/27/2014 | 10/28/2014 | 10/28/2014 11:18:23 AM | A | PASS |
|
|
Contact Mark Phone #: ###-#### Inspection requested via web by Tom Betty Grill wall rough in pk cover
|
ELE14-02777
| Final | 10/28/2014 | 10/28/2014 | 10/28/2014 10:36:15 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt Final ok
|
ELE14-03002
| Final | 10/27/2014 | 10/28/2014 | 10/28/2014 10:02:45 AM | A | PASS |
|
|
wire ac Phone #: ###-#### Inspection requested via web by PAT MILLER AC Final ok
|
ELE14-03002
| Electrical Rough-In | 10/27/2014 | 10/28/2014 | 10/28/2014 10:02:16 AM | A | PASS |
|
|
wire ac Phone #: ###-#### Inspection requested via web by PAT MILLER AC rough in ok
|
ELE14-01436
| Final | 10/27/2014 | 10/28/2014 | 10/28/2014 9:46:20 AM | A | FAIL |
|
|
Please call Stephanie when you are on your way ###-####, thank you. Phone #: ###-#### Inspection requested via web by Clay Morgan 314.25 Covers and Canopies. In completed installations, each box shall have a cover, patio wall lights. 422.30 General. A means shall be provided to simultaneously disconnect each appliance from all ungrounded conductors in accordance with the following sections of Part III. Water heater.
|
ELE14-02991
| Final | 10/27/2014 | 10/28/2014 | 10/28/2014 8:57:30 AM | A | CANC |
|
|
Temp power at transformer Phone #: ###-#### Inspection requested via web by kendall bender Needed temp service inspection
|
ELE14-02991
| Temporary Service | 10/28/2014 | 10/28/2014 | 10/28/2014 8:57:04 AM | P | PASS |
|
|
Temp power at transformer Phone #: ###-#### Inspection requested via web by kendall bender t/s u/g n ok
|