MEC16-04756
| Conference | 10/27/2016 | 10/28/2016 | 10/28/2016 4:02:07 PM | P | PASS |
|
|
Feel free to contact value heating ###-#### Phone #: ###-#### Inspection requested via web by Dan Ricken
|
MEC16-03725
| Final | 10/27/2016 | 10/28/2016 | 10/28/2016 3:31:12 PM | P | PASS |
|
|
Air balance test is finished. Please call Jason @ ###-#### to let him know you''re on your way. Thank you! Phone #: ###-#### Inspection requested via web by Rick Borg
|
MEC15-05739
| Final | 10/28/2016 | 10/28/2016 | 10/28/2016 3:12:34 PM | P | PART |
|
|
TCO Floors 1, 2, 3, and 4. Please call Pat N. prior to arrival. Phone #: ###-#### Inspection requested via web by Melissa Kaae floors 1-5 temp C.O. doors need to come off for return air till louvers arrive
|
MEC16-04783
| Final | 10/28/2016 | 10/28/2016 | 10/28/2016 2:48:39 PM | P | PASS |
|
|
Would like between 2-3. Thank you! Phone #: ###-#### Inspection requested via web by Xanti Berria
|
MEC16-04797
| Final | 10/27/2016 | 10/28/2016 | 10/28/2016 2:37:26 PM | P | PASS |
|
|
call to get access Phone #: ###-#### Inspection requested via web by Marisa Hone
|
MEC16-04787
| Rough-in | 10/28/2016 | 10/28/2016 | 10/28/2016 2:24:17 PM | P | FAIL |
|
|
Call Max for access code or to meet you there ###-#### Inspection requested via web by Floyd Floyd Peek line set gas piping to be finished, and pressure test, duct sealer needs to be completted
|
MEC16-03249
| Rough-in | 10/28/2016 | 10/28/2016 | 10/28/2016 1:24:26 PM | P | PASS |
|
|
Will-2nd floor Phone #: ###-#### 2nd floor ok for cover
|
MEC16-01373
| Mec-Aging Inspection | 10/28/2016 | 10/28/2016 | 10/28/2016 1:01:16 PM | | PEND |
|
|
|
MEC15-04824
| Mec-Aging Inspection | 10/28/2016 | 10/28/2016 | 10/28/2016 11:19:41 AM | | PEND |
|
|
|
MEC16-02081
| Rough-in | 10/28/2016 | 10/28/2016 | 10/28/2016 11:08:52 AM | P | CANC |
|
|
2nd floor rough in inspection please thank you Phone #: ###-#### Inspection requested via web by Dustin Rich need 2nd floor changes resubmitted to city for approval
|
MEC16-04574
| Final | 10/27/2016 | 10/28/2016 | 10/28/2016 11:05:26 AM | A | PASS |
|
|
clearance is fixed Phone #: ###-#### Inspection requested via web by Krista Boss
|
MEC16-03671
| Final | 10/27/2016 | 10/28/2016 | 10/28/2016 10:57:49 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer
|
MEC16-03337
| Final | 10/27/2016 | 10/28/2016 | 10/28/2016 10:45:45 AM | A | PASS |
|
|
Please call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day
|
MEC16-03453
| Final | 10/27/2016 | 10/28/2016 | 10/28/2016 10:17:02 AM | A | PASS |
|
|
PLease call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day
|
MEC16-04390
| Rough-in | 10/27/2016 | 10/28/2016 | 10/28/2016 9:57:30 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero
|
MEC16-04736
| Final | 10/27/2016 | 10/28/2016 | 10/28/2016 9:38:15 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
MEC16-04641
| Pressure Test | 10/27/2016 | 10/28/2016 | 10/28/2016 8:54:55 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer 20lb gas
|
MEC16-04641
| Rough-in | 10/27/2016 | 10/28/2016 | 10/28/2016 8:52:15 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer 1st floor boots need to be sealed to the floor, office needs 6x14 transfer
|