Inspections for the day of: Monday, October 28, 2019.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-04113 Rough-In Permanent Service10/28/201910/28/201910/29/2019 8:31:53 AMPCANC
Just SW of Fairview / 5 Mile intersection. After 2pm preferrably if possible. Thank you! Phone #: ###-#### Inspection requested via web by Dan Jennings...rough only...perm service not ready needs platform poured
ELE19-04113 Electrical Rough-In10/28/201910/28/201910/28/2019 3:00:16 PMPPASS
Just SW of Fairview / 5 Mile intersection. After 2pm preferrably if possible. Thank you! Phone #: ###-#### Inspection requested via web by Dan Jennings...rough ok to cover only
ELE19-04114 Rough-In Permanent Service10/28/201910/28/201910/28/2019 2:59:28 PMPNR
Just SW of Fairview/5 Mile intersection. After 2pm preferrably if possible. Thank you! Phone #: ###-#### Inspection requested via web by Dan Jennings...not ready...rescheduled next day AM
ELE19-04135 Final10/25/201910/28/201910/28/2019 2:16:51 PMPFAIL
Electrician: Matt
Prop. owner: Scott Prestel ###-#### Phone #: ###-#### Inspection requested via web by Same Electric....

glass windows within 5ft of edge of hot tub or pools shall be tempered
verified by film marking or new windows with marking..contractor and homeowner have been made aware of building code violation
ELE19-03909 Electrical Rough-In10/28/201910/28/201910/28/2019 1:43:34 PMPFAIL
Phone #: ###-#### Inspection requested via web by BRS Permitting...
no one on site
no material onsite
ELE19-03703 Electrical Rough-In10/23/201910/28/201910/28/2019 1:35:52 PMPPASS
Can we do a 1PM inspection in conjunction with a power to panel that we need in order to turn the power back on after doing a meter upgrade? Phone #: ###-#### Inspection requested via web by Kilee Russell...
UL listings verified...will require access to backyard for final
ELE19-03703 Permanent Service10/23/201910/28/201910/28/2019 1:34:58 PMPPASS
Can we do a 1PM inspection in conjunction rough inspection? We need this inspection because we are doing a meter upgrade and in order to turn the power back on. Phone #: ###-#### Inspection requested via web by Kilee Russell...
guide wire kit required
p/s o/h reconnect ok
ELE19-03569 Final10/28/201910/28/201910/28/2019 12:33:25 PMPFAIL
Please contact Bruce with any questions. Have a lovely afternoon! Phone #: ###-#### Inspection requested via web by JENNY EMEL...
1) all recepticles 120/240 volt single or 3 phase shall have GFCI protection in kitchen area including behind counter for employees
2) all hard wired appliances shall have means to lockout in the off position at the OCPD
3) access required to verify units on roof top
4) proper access to junction boxes/outlets required...outlet in cabinet
ELE19-02836 Final10/28/201910/28/201910/28/2019 11:48:29 AMPFAIL
Phone #: ###-#### Inspection requested via web by Angela Stears...unable to final until A/C whip has been installed or another permit is pulled for the hookup of the A/C
ELE19-01582 Conference10/28/201910/28/201910/28/2019 11:28:54 AMPPASS
Conference concerning underground work. Please contact Shannon onsite. Phone #: ###-#### Inspection requested via web by Deb Ipsen..depths of pipes into panel room from pumps for pump controls
ELE19-04147 Temporary Service10/28/201910/28/201910/28/2019 11:09:10 AMPPASS
Phone #: ###-#### Inspection requested via web by Robert Murray...t/s u/g new ok
ELE19-04148 Temporary Service10/28/201910/28/201910/28/2019 11:08:47 AMPPASS
Phone #: ###-#### Inspection requested via web by Robert Murray..t/s u/g new ok
ELE19-03269 Final10/25/201910/28/201910/28/2019 10:58:55 AMAPASS
Garage code 2018 or 2019 Phone #: ###-#### Inspection requested via web by Darryn Coburn...ok to final
ELE19-02892 Final10/25/201910/28/201910/28/2019 10:57:14 AMAPASS
garage code 2018 or 2019, thank you! Phone #: ###-#### Inspection requested via web by Darryn Coburn...ok to final
ELE19-03038 Electrical Rough-In10/28/201910/28/201910/28/2019 10:12:52 AMPPASS
Phone #: 2089546453 >> Inspection requested via mobile web by Don Taylor...rough ok first bathroom-master
ELE19-03130 Final10/25/201910/28/201910/28/2019 9:53:12 AMAPASS
Call Luke ###-#### on your way and with any questions please. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan...
corrections made-circuit directory and neutral seperation

connected load re-engineered by engineer to show full connected load of existing business and new appliances-meets requirements...future loads added by neighboring business will need addressed at that time...ID Power is aware of issue
ELE19-02601 Final10/25/201910/28/201910/28/2019 9:18:04 AMAFAIL
Builder Has No Access Code-Home Will Be "Open"

Builder Phone Number is ###-#### Phone #: ###-#### Inspection requested via web by Paula Gratiot...
1..outlet in closet shows open neutral
2..light in storage closet needs installed
3...furnaces need labelled as to which is which for circuit size
ELE19-04134 Temporary Service10/25/201910/28/201910/28/2019 8:32:51 AMAPASS
Phone #: ###-#### Inspection requested via web by David Nelson...
t/s u/g new ok
ELE19-04130 Temporary Service10/25/201910/28/201910/28/2019 8:32:20 AMAPASS
Phone #: ###-#### Inspection requested via web by David Nelson...
t/s u/g new ok
ELE17-03540 DOC - Permit Expired10/28/201910/28/201910/28/2019 8:25:44 AMAPASS
permit expired...no activity over 180 days
ELE19-02892 Final10/25/201910/28/201910/25/2019 1:18:22 PMACANC
garage code 2468, thank you! Phone #: ###-#### >> Inspection requested via web by Darryn Coburn Inspection cancelled from web by: Darryn Coburn