ELE13-02928
| Rough-In Permanent Service | 10/29/2013 | 10/29/2013 | 10/29/2013 3:27:48 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov rough-in p/s u/g n ok 4 plex
|
ELE13-02585
| Final | 10/29/2013 | 10/29/2013 | 10/29/2013 3:24:07 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov final ok No card on site. Did witness non licenceTaylor Cerrello(Biltmore Company employee) incorrectly installing dryer cords. Notified electrical contractor Ultimate Electric and general contractor Biltmore Company(Pat) of this violation.
|
ELE13-02638
| Final | 10/28/2013 | 10/29/2013 | 10/29/2013 1:25:40 PM | P | PASS |
|
|
Final Inspection on Shop. Tim ###-#### Phone #: ###-#### >> Inspection requested via web by Tim Lawrence final ok
|
GCE13-00179
| GCE-Permanent Service | 10/29/2013 | 10/29/2013 | 10/29/2013 1:01:16 PM | P | PASS |
|
|
Tom ###-#### p/s u/g rec ok
|
ELE13-03010
| Electrical Rough-In | 10/29/2013 | 10/29/2013 | 10/29/2013 12:43:19 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Eric Brown rough-in ok cover kitchen-dinning remodel
|
ELE13-03011
| Electrical Rough-In | 10/29/2013 | 10/29/2013 | 10/29/2013 12:08:41 PM | P | PASS |
|
|
David Phone #: ###-#### rough-in ok cover
|
ELE13-02908
| Permanent Service | 10/28/2013 | 10/29/2013 | 10/29/2013 9:41:47 AM | A | PASS |
|
|
ACCESS CODE - 4353. The water piping has been bonded, thanks, TW. Phone #: ###-#### >> Inspection requested via web by Stephen Kren correction done, p/s u/g rec ok
|
ELE13-02930
| Final | 10/28/2013 | 10/29/2013 | 10/29/2013 9:19:49 AM | A | PASS |
|
|
GREG Phone #: ###-#### corrections done, p/s o/h rec ok
|
ELE13-03001
| Permanent Service | 10/28/2013 | 10/29/2013 | 10/29/2013 8:59:56 AM | A | PASS |
|
|
Brent Phone #: ###-#### p/s o/h rec ok
|
ELE13-02743
| Final | 10/28/2013 | 10/29/2013 | 10/29/2013 8:49:39 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson correction done, final ok
|
ELE13-02911
| Electrical Rough-In | 10/25/2013 | 10/29/2013 | 10/29/2013 8:31:45 AM | A | PASS |
|
|
underground Phone #: ###-#### >> Inspection requested via web by Louis Keller rough-in ok cover underground, pvc conduits lessthan 18 in. shall have GFCI protection
|
ELE13-02822
| Electrical Rough-In | 10/28/2013 | 10/29/2013 | 10/29/2013 8:18:25 AM | A | FAIL |
|
|
The key is on the left side of the entrance under one of the rock ledges, please call for any questions, thx, TW. Phone #: ###-#### >> Inspection requested via web by Stephen Kren NEC 330.12(1) nail plates, Missing mudrings
|
ELE13-02653
| Electrical Rough-In | 10/28/2013 | 10/29/2013 | 10/28/2013 3:58:01 PM | A | PASS |
|
|
Cover inspection for HP building 2 lower bathrooms. Please call Guy Thomas with any questions ###-#### Phone #: ###-#### >> Inspection requested via web by Clint Tate rough-in ok cover ceiling grid
|
ELE13-02576
| Electrical Rough-In | 10/28/2013 | 10/29/2013 | 10/28/2013 2:43:25 PM | A | CANC |
|
|
Cover inspection for HP building 2 lower bathrooms. If you have any questions please contact Guy Thomas ###-#### Phone #: ###-#### >> Inspection requested via web by Clint Tate Inspection cancelled from web by: Clint Tate
|