ELE12-01498
| ELE-Aging Inspection | 10/29/2015 | 10/29/2015 | 10/30/2015 11:28:58 AM | | DONE |
|
|
Still under construction
|
ELE15-02598
| Final | 10/29/2015 | 10/29/2015 | 10/29/2015 4:35:03 PM | P | PASS |
|
|
Final on Walmart. Contact is Jay Sprik. Phone #: ###-#### Inspection requested via web by Richard Montgomery Final ok
|
ELE15-03466
| Electrical Rough-In | 10/29/2015 | 10/29/2015 | 10/29/2015 3:40:18 PM | P | PASS |
|
|
Underground electrical from transformer to building. Phone #: ###-#### Inspection requested via web by Richard Montgomery As noted rough in ok cover
|
ELE14-01066
| Electrical Rough-In | 10/29/2015 | 10/29/2015 | 10/29/2015 3:05:29 PM | P | PASS |
|
|
Ceiling grid for tile cover, H building, 3rd floor, Corridors H360, H365, H368 and Rooms H369, H363. Contact Craig Timmons @ ###-#### or Bob Mott Phone #: ###-#### Inspection requested via web by Cathy Duchek Also checked corridor 356, 357. Grid rough in ok cover as noted
|
ELE14-02371
| Final | 10/29/2015 | 10/29/2015 | 10/29/2015 3:02:51 PM | P | PASS |
|
|
Bldg F Floor 1,2,3 done 10-23-15 Floor 4 don 9-21-15, Bldg G Floor 1,2,3 done 10-27-15. Final ok
|
ELE15-03309
| Final | 10/28/2015 | 10/29/2015 | 10/29/2015 1:20:51 PM | A | FAIL |
|
|
Jay Phone #: ###-#### 110.12- Unused openings shall be closed. 1/2" KO seals above grid boxes. 314.25- All boxes shall be covered. 406.6- All receptacles shall have covers.
|
ELE15-03461
| Permanent Service | 10/28/2015 | 10/29/2015 | 10/29/2015 12:43:07 PM | A | PASS |
|
|
We Would Like,To Get Permanent Service As,Well As Some Underground To A Future Out Building Please And Thank You Call With Any Questions Or,Concerns. Phone #: ###-#### Inspection requested via web by jason shifflett p/s u/g n ok
|
ELE15-03461
| Electrical Rough-In | 10/29/2015 | 10/29/2015 | 10/29/2015 12:42:21 PM | P | PASS |
|
|
We Would Like,To Get Permanent Service As,Well As Some Underground To A Future Out Building Please And Thank You Call With Any Questions Or,Concerns. Phone #: ###-#### Inspection requested via web by jason shifflett Underground to back out building rough in ok cover
|
ELE15-03484
| Conference | 10/28/2015 | 10/29/2015 | 10/29/2015 12:29:52 PM | A | DONE |
|
|
After 10 // Katie Phone #: ###-#### Discussed code requirements for enclosed sun room.
|
ELE15-03396
| Electrical Rough-In | 10/28/2015 | 10/29/2015 | 10/29/2015 11:54:04 AM | A | PASS |
|
|
We need an underground inspection. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker Underground to east electrical room and concrete encased electrode rough in ok cover
|
ELE15-03425
| Final | 10/28/2015 | 10/29/2015 | 10/29/2015 11:40:06 AM | A | PASS |
|
|
Mike Phone #: ###-#### Final ok
|
ELE15-03425
| Electrical Rough-In | 10/29/2015 | 10/29/2015 | 10/29/2015 11:39:12 AM | P | PASS |
|
|
Mike Phone #: ###-#### Roof AC rough in ok cover
|
ELE15-03099
| Final | 10/28/2015 | 10/29/2015 | 10/29/2015 11:17:08 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt Final ok
|
ELE15-03409
| Rough-In Permanent Service | 10/29/2015 | 10/29/2015 | 10/29/2015 10:59:19 AM | P | PASS |
|
|
READY NOW Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover p/s u/g n ok
|
ELE15-03503
| Rough-In Permanent Service | 10/28/2015 | 10/29/2015 | 10/29/2015 10:40:48 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI 110.3- NM cable has damaged insulation up bed front west. 300.4- NM cable shall be protected from physical damage where bored hole does not maintain 1 1/4" from framing surface. Up bed front east under switch.
|
ELE15-03494
| Electrical Rough-In | 10/28/2015 | 10/29/2015 | 10/29/2015 10:10:19 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Atkins Installed 110 amp outdoor panel on back of store to feed a air system to dry and test contamination underground. Rough in ok
|
ELE15-00338
| Electrical Rough-In | 10/28/2015 | 10/29/2015 | 10/29/2015 9:40:48 AM | A | PASS |
|
|
Butch Phone #: ###-#### Walls and hardlids all units rough in ok cover
|