Inspections for the day of: Monday, October 3, 2005.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03438 Electrical Rough-In10/3/200510/3/200510/3/2005 4:35:38 PMPPASS
Charlie Internet Inspection Request from: Melyne Davis ric ok, need to change room count to 6 and a/c
ELE05-03253 Electrical Rough-In9/30/200510/3/200510/3/2005 3:19:12 PMPFAIL
vivian; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, left message, left corr notice, 300.4(D) nm cable shall be 1 1/4" from edge of framing members, 210.52(A)(1) recpts shall be spaced so that no point is more than 6' from a recpt outlet, 314.20 boxes in combustible material shall be flush or project therefrom,300.3(C) and 725.55(A) low voltage ckt shall not be run with power ckts,300.4 conductors shall be protected form damage (outside lite boxes)
ELE05-03549 Permanent Service9/28/200510/3/200510/3/2005 1:35:51 PMPPASS
mitch ###-#### p/s u/g exst reconnect ok
ELE05-03438 Electrical Rough-In9/30/200510/3/200510/3/2005 10:44:49 AMANR
Charlie Internet Inspection Request from: Melyne Davis called contr, no access
ELE05-03407 Rough-In Permanent Service9/30/200510/3/200510/3/2005 10:42:21 AMAPASS
Scheduled by a contractor via Hello! on 9/30/2005 at 7:51:10 AM. Contact: ###-####. ric ok p/s u/g n ok
ELE05-02940 Final9/30/200510/3/200510/3/2005 9:45:00 AMAPART
darrell; Phone #: ###-#### Internet Inspection Request from: Barbara Moore called contr, need to see upstairs bath and disposal. Rest ok.
ELE05-02893 Electrical Rough-In9/30/200510/3/200510/3/2005 9:05:10 AMAFAIL
this is for a reinspection. any questions please call Chris Hill.; Phone #: ###-#### Internet Inspection Request from: Jeff Radford met gen contr, signed t/o card, called contr, left corr notice, 314.23(C) recpt shall securely mounted to wall ne room and back door, 408.4 panel schedule shall be detailed to distinguish each circuit, fixtures shall be inspected once installed 3 places in front lobby.
ELE05-03085 Final9/30/200510/3/200510/3/2005 8:41:28 AMAPASS
Scheduled by a contractor via Hello! on 9/30/2005 at 2:05:18 PM. Contact: ###-####. ok to final
ELE05-03180 Electrical Rough-In9/30/200510/3/200510/3/2005 8:21:23 AMAPASS
Scheduled by a contractor via Hello! on 9/30/2005 at 2:05:03 PM. ###-####. ok to cover bath walls and column in front area, hall area walls too.