Inspections for the day of: Tuesday, October 3, 2006.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-03324 Permanent Service10/3/200610/3/200610/3/2006 3:41:43 PMPPASS
Terry, please call 1st for access instructions; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt p/s u/g new ok
ELE04-00305 Electrical Rough-In10/2/200610/3/200610/3/2006 2:53:50 PMPFAIL
Charles no #, will call you to arrange time
corr. posted 03-06-06, 314.16 box fill, remove all devices installed so I can inspect makeup room back of garage not done, 10-03-06, built his own jbox, wireway ? dose not meet NEC 314.40,41 has high and low voltage mixed in it, 300.14 needs 6" free length conductor all locations,250.130 (C) 1,2,3,4,5 nongrounding recept replacement or branch circuit extensions shall meet rquirements as code noted states, or see 406.3 (D) for gfci protection for ungrounded systems, 300.3(B) shall install equip grd wire in raceway not on the outside of it 1/2 EMT in homemade jbox
ELE06-03664 Final10/2/200610/3/200610/3/2006 1:38:37 PMPNR
KIM; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy see added r/i
ELE06-03664 Electrical Rough-In10/3/200610/3/200610/3/2006 1:38:14 PMPPART
KIM; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy
partial r/i not ready for final, still needs wiring for new counter
ELE06-03672 Final10/3/200610/3/200610/3/2006 1:37:00 PMPPASS
paul; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
ELE06-02896 Electrical Rough-In10/3/200610/3/200610/3/2006 12:30:03 PMPPART
Ufer ground inspection ; Phone #: ###-#### Internet Inspection Request from: Jari Rivers electrode ok
ELE06-02993 Electrical Rough-In10/2/200610/3/200610/3/2006 11:44:27 AMAPASS
EQUIPOTNTIAL GRID; Phone #: ###-#### Internet Inspection Request from: Lee ok
ELE06-00460 Electrical Rough-In10/2/200610/3/200610/3/2006 10:20:03 AMAPART
###-#### - duke walls main stairway
ELE06-03296 Rough-In Permanent Service10/2/200610/3/200610/3/2006 9:47:40 AMAPART
Phone #: ###-#### Internet Inspection Request from: Zane Robertson r/i ok
ELE06-03018 Final10/2/200610/3/200610/3/2006 9:24:47 AMAPASS
call for access Brian Miller; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok card signed
ELE06-02075 Electrical Rough-In10/2/200610/3/200610/3/2006 9:01:35 AMAPART
scott Note: underground; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles u/g for light SE end of lot
ELE06-01902 Final10/2/200610/3/200610/3/2006 8:42:12 AMAPASS
This is the Quality Thermistor monument sign on the corner of Century and Centurian; Phone #: ###-#### Internet Inspection Request from: Eric Shaner sign ok only
ELE05-04574 ELE-Aging Inspection10/3/200610/3/200610/3/2006 8:16:29 AM DONE
ELE05-04574 DOC - Permit Expired10/3/200610/3/200610/3/2006 8:16:20 AMAPASS
no work being done on job called
ELE05-04620 ELE-Aging Inspection10/3/200610/3/200610/3/2006 8:14:24 AM DONE
wrong address for permit # should have been voided
ELE05-04620 DOC - Permit Expired10/3/200610/3/200610/3/2006 8:13:22 AMAPASS
ELE05-04498 ELE-Aging Inspection10/3/200610/3/200610/3/2006 8:10:32 AM PART
wsuc