ELE06-03324
| Permanent Service | 10/3/2006 | 10/3/2006 | 10/3/2006 3:41:43 PM | P | PASS |
|
|
Terry, please call 1st for access instructions; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt p/s u/g new ok
|
ELE04-00305
| Electrical Rough-In | 10/2/2006 | 10/3/2006 | 10/3/2006 2:53:50 PM | P | FAIL |
|
|
Charles no #, will call you to arrange time corr. posted 03-06-06, 314.16 box fill, remove all devices installed so I can inspect makeup room back of garage not done, 10-03-06, built his own jbox, wireway ? dose not meet NEC 314.40,41 has high and low voltage mixed in it, 300.14 needs 6" free length conductor all locations,250.130 (C) 1,2,3,4,5 nongrounding recept replacement or branch circuit extensions shall meet rquirements as code noted states, or see 406.3 (D) for gfci protection for ungrounded systems, 300.3(B) shall install equip grd wire in raceway not on the outside of it 1/2 EMT in homemade jbox
|
ELE06-03664
| Final | 10/2/2006 | 10/3/2006 | 10/3/2006 1:38:37 PM | P | NR |
|
|
KIM; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy see added r/i
|
ELE06-03664
| Electrical Rough-In | 10/3/2006 | 10/3/2006 | 10/3/2006 1:38:14 PM | P | PART |
|
|
KIM; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy partial r/i not ready for final, still needs wiring for new counter
|
ELE06-03672
| Final | 10/3/2006 | 10/3/2006 | 10/3/2006 1:37:00 PM | P | PASS |
|
|
paul; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
|
ELE06-02896
| Electrical Rough-In | 10/3/2006 | 10/3/2006 | 10/3/2006 12:30:03 PM | P | PART |
|
|
Ufer ground inspection ; Phone #: ###-#### Internet Inspection Request from: Jari Rivers electrode ok
|
ELE06-02993
| Electrical Rough-In | 10/2/2006 | 10/3/2006 | 10/3/2006 11:44:27 AM | A | PASS |
|
|
EQUIPOTNTIAL GRID; Phone #: ###-#### Internet Inspection Request from: Lee ok
|
ELE06-00460
| Electrical Rough-In | 10/2/2006 | 10/3/2006 | 10/3/2006 10:20:03 AM | A | PART |
|
|
###-#### - duke walls main stairway
|
ELE06-03296
| Rough-In Permanent Service | 10/2/2006 | 10/3/2006 | 10/3/2006 9:47:40 AM | A | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Zane Robertson r/i ok
|
ELE06-03018
| Final | 10/2/2006 | 10/3/2006 | 10/3/2006 9:24:47 AM | A | PASS |
|
|
call for access Brian Miller; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok card signed
|
ELE06-02075
| Electrical Rough-In | 10/2/2006 | 10/3/2006 | 10/3/2006 9:01:35 AM | A | PART |
|
|
scott Note: underground; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles u/g for light SE end of lot
|
ELE06-01902
| Final | 10/2/2006 | 10/3/2006 | 10/3/2006 8:42:12 AM | A | PASS |
|
|
This is the Quality Thermistor monument sign on the corner of Century and Centurian; Phone #: ###-#### Internet Inspection Request from: Eric Shaner sign ok only
|
ELE05-04574
| ELE-Aging Inspection | 10/3/2006 | 10/3/2006 | 10/3/2006 8:16:29 AM | | DONE |
|
|
|
ELE05-04574
| DOC - Permit Expired | 10/3/2006 | 10/3/2006 | 10/3/2006 8:16:20 AM | A | PASS |
|
|
no work being done on job called
|
ELE05-04620
| ELE-Aging Inspection | 10/3/2006 | 10/3/2006 | 10/3/2006 8:14:24 AM | | DONE |
|
|
wrong address for permit # should have been voided
|
ELE05-04620
| DOC - Permit Expired | 10/3/2006 | 10/3/2006 | 10/3/2006 8:13:22 AM | A | PASS |
|
|
|
ELE05-04498
| ELE-Aging Inspection | 10/3/2006 | 10/3/2006 | 10/3/2006 8:10:32 AM | | PART |
|
|
wsuc
|