FIR06-00223
| INSP-Final Inspection | 10/3/2007 | 10/3/2007 | 10/4/2007 8:13:06 AM | P | FAIL |
|
|
Provide orfice in the sprinkler test line and test the flow switch and alarm bell. Flush the underground supply piping. Provide signage at the riser. Provide hydraulic sticker, head box, spare sprinklers and head wrench. Mount the riser against the wall. Provide the missing sprinkler canopies and replace the sprinkler canopies that have been painted unless verification can be provided that they were factory painted.
|
BLD05-00633
| FIRE-Final Inspection | 10/3/2007 | 10/3/2007 | 10/4/2007 8:00:15 AM | P | FAIL |
|
|
Inspection was to check the operation of the emergency lights and exit signs. We found out that by testing the emergency generator the pharmacy would be shut down which was not going to be acceptable by the st als people so no test was performed.
|
FIR07-00679
| INSP-Final Inspection | 10/2/2007 | 10/3/2007 | 10/4/2007 7:50:51 AM | A | PASS |
|
|
permit finaled
|
FIR07-00798
| INSP-Alarm Testing | 10/2/2007 | 10/3/2007 | 10/4/2007 7:49:32 AM | P | DONE |
|
|
Permit is ready to be finaled but needs to ve called in as a final inspection
|
MIS07-00205
| FIR-Final | 10/3/2007 | 10/3/2007 | 10/4/2007 7:47:28 AM | P | FAIL |
|
|
The exit lights and emergency lights at the west end of the sanctuary are wired into the lighting circuit and can be turned off with the switch. Again this inspection is for the upper floor only.
|
FIR06-00778
| INSP-Final Inspection | 10/1/2007 | 10/3/2007 | 10/3/2007 2:45:23 PM | A | CANC |
|
|
Per Brian there is no access. Permit to be rescheduled
|
FIR07-00611
| INSP-Final Inspection | 10/1/2007 | 10/3/2007 | 10/3/2007 12:32:27 PM | A | PASS |
|
|
permit finaled
|
FIR07-00607
| INSP-Final Inspection | 10/1/2007 | 10/3/2007 | 10/3/2007 12:09:03 PM | A | PASS |
|
|
Permit finaled
|
FIR07-00604
| INSP-Final Inspection | 10/1/2007 | 10/3/2007 | 10/3/2007 11:01:11 AM | A | PASS |
|
|
Permit finaled
|
FIR06-00911
| INSP-Final Inspection | 10/1/2007 | 10/3/2007 | 10/3/2007 10:14:44 AM | A | PASS |
|
|
Permit finaled
|
FIR07-00724
| INSP-Final Inspection | 10/2/2007 | 10/3/2007 | 10/3/2007 10:09:49 AM | A | PASS |
|
|
permit finaled
|
FIR06-00957
| INSP-Final Inspection | 10/2/2007 | 10/3/2007 | 10/3/2007 8:58:25 AM | A | PASS |
|
|
permit finaled
|
FIR06-00956
| INSP-Final Inspection | 10/2/2007 | 10/3/2007 | 10/3/2007 8:57:48 AM | A | PASS |
|
|
Permit finaled
|
FIR07-00771
| INSP-Sprinkler Rough-in | 10/1/2007 | 10/3/2007 | 10/3/2007 8:51:34 AM | A | PASS |
|
|
permit finaled
|
FIR07-00771
| INSP-Final Inspection | 10/1/2007 | 10/3/2007 | 10/3/2007 8:50:27 AM | A | PASS |
|
|
permit finaled
|