ELE06-02374
| ELE-Aging Inspection | 10/3/2008 | 10/3/2008 | 10/7/2008 10:40:29 AM | | DONE |
|
|
see doc expired 7/31/08
|
ELE08-02687
| Final | 10/2/2008 | 10/3/2008 | 10/3/2008 4:00:44 PM | P | PASS |
|
|
ready for rough in Phone #: ###-#### Internet Inspection Request from: gary batten ok to final, no esc this project
|
ELE08-02687
| Electrical Rough-In | 10/3/2008 | 10/3/2008 | 10/3/2008 3:50:19 PM | P | PASS |
|
|
ready for rough in Phone #: ###-#### Internet Inspection Request from: gary batten ric ok, no esc this project
|
ESC08-00653
| General Inspection | 10/3/2008 | 10/3/2008 | 10/3/2008 3:47:25 PM | P | PASS |
|
|
looked ok
|
ESC08-00084
| General Inspection | 10/3/2008 | 10/3/2008 | 10/3/2008 3:46:37 PM | P | PASS |
|
|
looked ok
|
ESC08-00694
| General Inspection | 10/3/2008 | 10/3/2008 | 10/3/2008 3:45:33 PM | A | PASS |
|
|
looked ok
|
ESC08-00313
| General Inspection | 10/3/2008 | 10/3/2008 | 10/3/2008 3:44:43 PM | A | PASS |
|
|
looked ok
|
ESC08-00757
| General Inspection | 10/3/2008 | 10/3/2008 | 10/3/2008 3:43:49 PM | A | PASS |
|
|
looked ok
|
ESC07-01595
| General Inspection | 10/3/2008 | 10/3/2008 | 10/3/2008 3:42:58 PM | A | PASS |
|
|
looked ok
|
ESC08-00252
| General Inspection | 10/3/2008 | 10/3/2008 | 10/3/2008 3:41:57 PM | A | PASS |
|
|
looked ok
|
ESC07-01540
| General Inspection | 10/3/2008 | 10/3/2008 | 10/3/2008 3:41:14 PM | A | PASS |
|
|
looked ok
|
ELE08-02682
| Electrical Rough-In | 10/3/2008 | 10/3/2008 | 10/3/2008 3:39:48 PM | P | PASS |
|
|
John Phone #: ###-#### ric ok garage, no esc this project
|
ELE08-02656
| Permanent Service | 10/3/2008 | 10/3/2008 | 10/3/2008 2:57:05 PM | P | PASS |
|
|
p/s o/h rec ok
|
ELE08-02694
| Rough-In Permanent Service | 10/3/2008 | 10/3/2008 | 10/3/2008 1:55:38 PM | P | FAIL |
|
|
Paul Phone #: ###-#### called, left message, left correction notice, NEC 110.12(A) shall close breaker opening, 358.30 shall strap emt within 3' of panel, 312.5 shall provide abrasion protection for all conductors entering enclosure (meter can), 400.8 shall not use so cord for fixed wiring of structure, 250.52(A) shall provide metal water pipe ground, 250.56 shall augmeny ground rod with 1 additional, BCC no violations shall be retained, no esc this project
|
ELE08-02660
| Final | 10/3/2008 | 10/3/2008 | 10/3/2008 1:17:26 PM | P | PASS |
|
|
ROBERT Phone #: ###-#### corrections made, ok to final, no esc this project
|
ELE08-01563
| Electrical Rough-In | 10/3/2008 | 10/3/2008 | 10/3/2008 12:33:43 PM | P | PASS |
|
|
jason Note:wall Phone #: ###-#### 2nd floor walls only ok to cover anop
|
ELE08-00307
| Electrical Rough-In | 10/2/2008 | 10/3/2008 | 10/3/2008 11:21:31 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 10/2/2008 at 2:49:24 PM. Contact: ###-####. corrections made, ok to cover ceiling, no esc this project
|
ELE08-02688
| Electrical Rough-In | 10/2/2008 | 10/3/2008 | 10/3/2008 10:40:26 AM | A | PASS |
|
|
dustin Phone #: ###-#### ric ok
|
ELE08-00705
| Final | 10/2/2008 | 10/3/2008 | 10/3/2008 10:17:26 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 10/2/2008 at 12:23:49 PM. Contact: ###-####. ok to final
|
ELE08-02685
| Final | 10/2/2008 | 10/3/2008 | 10/3/2008 9:38:10 AM | A | PASS |
|
|
martin- call 15 min prior to insp- homeowner requirement for permit ele08-02685 Phone #: ###-#### met owner, ok to final, no esc this project
|
ELE08-02384
| Electrical Rough-In | 10/2/2008 | 10/3/2008 | 10/3/2008 9:19:31 AM | A | PASS |
|
|
site lighting/ contact is Roger Reynolds ###-#### Phone #: ###-#### Internet Inspection Request from: Debby Ellis u/g ok to cover south 1/2 parking lot for lighting
|
ELE08-02494
| Final | 10/2/2008 | 10/3/2008 | 10/3/2008 8:54:42 AM | A | PASS |
|
|
addition only in rear Phone #: ###-#### Internet Inspection Request from: Shane Vigil called contractor, ok to final
|
ELE08-01572
| Final | 10/2/2008 | 10/3/2008 | 10/3/2008 8:28:53 AM | A | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Kathy Smith need to see panel schedules, some conduit strapping by panels, rest ok
|
ELE08-02114
| Final | 10/2/2008 | 10/3/2008 | 10/3/2008 8:01:47 AM | A | PASS |
|
|
Garage code 1234 Phone #: ###-#### Internet Inspection Request from: Therrin Robertson called, left survey, NEC 110.26(F)(2) no equipment shall be in dedicated space below panel, ok to final
|