Inspections for the day of: Thursday, October 3, 2013.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02513 Conference10/3/201310/3/201310/3/2013 1:54:02 PMPDONE
Scott Phone #: ###-#### Discussed requirements for final inspection
ELE13-02659 Final10/1/201310/3/201310/3/2013 1:49:26 PMPPASS
just getting final on lighting retrofit, rough in already passed. Phone #: ###-#### >> Inspection requested via web by Tim Dunlop final ok
ELE13-02743 Rough-In Permanent Service10/3/201310/3/201310/3/2013 12:37:54 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson rough-in p/s u/g n ok
ELE13-00837 Electrical Rough-In10/3/201310/3/201310/3/2013 12:27:29 PMPPASS
For cover in offices - Mark Phone #: ###-#### rough-in ok cover
ELE13-02430 Electrical Rough-In10/3/201310/3/201310/3/2013 11:55:30 AMPPASS
Floor box at east end of building, conduit running along north wall of building. Contact is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery rough-in ok cover interior under slab and floor box.
ELE13-02722 Final10/2/201310/3/201310/3/2013 10:17:05 AMAPASS
COntact is Carl Pettek ###-#### Phone #: ###-#### >> Inspection requested via web by Scott Campbell final ok
ELE13-02722 Electrical Rough-In10/3/201310/3/201310/3/2013 10:16:14 AMPPASS
COntact is Carl Pettek ###-#### Phone #: ###-#### >> Inspection requested via web by Scott Campbell rough-in ok
ELE13-02490 Final10/2/201310/3/201310/3/2013 9:54:38 AMAPASS
Please call Lynn at ###-#### with any questions comments or concerns. Phone #: ###-#### >> Inspection requested via web by Lynn Proctor final ok
ELE13-01598 Electrical Rough-In10/2/201310/3/201310/3/2013 9:18:33 AMAFAIL
steve please call before going out Phone #: ###-#### NEC 300.4 nail plates where bored holes are less than 1 1/4 from edge of framing member. NEC 334.30 Shall staple NM cable within 12 in. box or panel support NM cable every 4 1/2 feet
ELE13-02446 Final10/3/201310/3/201310/3/2013 8:53:47 AMAFAIL
added lights to area above bar, swapped existing dining area lights to LED. no work to outside or kitchen area. Dining area only. I''m not on site but can be reached by phone. Thanks Phone #: ###-#### >> Inspection requested via web by Jim Snodgrass Building requires posted address, NEC 110.12(A) unused openings KO plugs, empty conduit connectors
ELE13-02118 Rough-In Permanent Service10/2/201310/3/201310/3/2013 8:20:05 AMAPASS
p/s r/i and basement r/i -- David Phone #: ###-#### rough-in p/s o/h rec ok