Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-04417 Pressure Test10/2/201710/3/201710/3/2017 4:04:34 PMPPASS
Installer Miguel ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - 20lb gas pass
MEC17-04420 Final10/3/201710/3/201710/3/2017 3:22:10 PMPPASS
Please call Aaron with any questions. Thanks! Phone #: ###-#### Inspection requested via web by john shay
MEC16-04080 Mec-Aging Inspection10/3/201710/3/201710/3/2017 3:19:48 PM DONE
Expired
MEC16-04080 DOC - Permit Expired10/3/201710/3/201710/3/2017 3:19:48 PMPPASS
MEC16-04080 Pressure Test10/3/201710/3/201710/3/2017 1:55:54 PMPCANC
MEC17-04369 Final10/3/201710/3/201710/3/2017 1:55:28 PMPFAIL
Please call roughly an hour before expecting to be there so I can meet you out there. Thank you Phone #: ###-#### Inspection requested via web by Bradley Howard - Need CO sensor, Secondary condensate needs to be seperate from primary
MEC17-04369 Pressure Test10/3/201710/3/201710/3/2017 1:54:35 PMPPASS
Please call roughly an hour before expecting to be there so I can meet you out there. Thank you Phone #: ###-#### Inspection requested via web by Bradley Howard - 60lb gas
MEC17-01976 Rough-in10/2/201710/3/201710/3/2017 1:51:43 PMPPASS
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - okay to cover bottom of TGI's in units 207-212, & 214
MEC17-04420 Rough-in10/2/201710/3/201710/3/2017 11:00:55 AMAPASS
Please call Aaron with any questions. Thanks! Phone #: ###-#### Inspection requested via web by john shay
MEC17-04409 Pressure Test10/2/201710/3/201710/3/2017 9:42:57 AMAPASS
Call Josh Lebow prior to inspection ###-#### Phone #: ###-#### Inspection requested via web by Sheldon Lebow - 20lb gas
MEC17-04409 DOC - Permit Finaled10/3/201710/3/201710/3/2017 9:42:42 AMPPASS
MEC17-04174 Rough-in10/2/201710/3/201710/3/2017 9:03:07 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves -
1. Fresh air needs to go to the return air plenum.
2. Not all supply ducts installed per manual J.
3. Need ladder on site to access furnace in attic for inspection.
4. Need a clear and unobstructed passageway of not less than 30x22 to access equipment in a attic.
MEC17-03444 Final9/26/201710/3/20179/26/2017 3:09:10 PMACANC
PLEASE CALL JAMIE AT # LISTED WHEN EN ROUTE FOR DUCT WORK, GAS LINE/FIREPLACE GAS LINE, FURNACE, A/C, VENTING, & COIL INSTALLS Phone #: ###-#### >> Inspection requested via web by SOPHIA FLEMING Inspection cancelled from web by: SOPHIA FLEMING