MEC19-03096
| Rough-in | 10/3/2019 | 10/3/2019 | 10/3/2019 4:34:55 PM | P | FAIL |
|
|
2nd ; 3rd floor exhaust fans, 4th floor radiant dampers. Please call Bryan at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum - exhaust fans are not installed per prints on 2nd, 3rd and 4th floor
|
MEC19-03744
| Final | 10/2/2019 | 10/3/2019 | 10/3/2019 4:16:24 PM | P | PASS |
|
|
Please call home owner at ###-#### to confirm she is home and able to provide access. Phone #: ###-#### Inspection requested via web by terry Warden - final ok
|
MEC19-04400
| Final | 10/3/2019 | 10/3/2019 | 10/3/2019 2:54:04 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek - furnace only co ok
|
MEC19-04400
| Pressure Test | 10/3/2019 | 10/3/2019 | 10/3/2019 2:53:48 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek - 5lb flue pressure test ok
|
MEC19-04351
| Final | 10/2/2019 | 10/3/2019 | 10/3/2019 2:11:52 PM | P | FAIL |
|
|
Please call realtor Jenny at Lysi Bishop at ###-#### and she will meet you for access Phone #: ###-#### Inspection requested via web by Justin Osterhout - furnace PVC flue needs 6" clearances from single wall water heater flue
|
MEC19-04347
| Final | 10/1/2019 | 10/3/2019 | 10/3/2019 1:47:03 PM | P | NR |
|
|
field super : chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC19-00986
| Final | 10/2/2019 | 10/3/2019 | 10/3/2019 1:35:21 PM | P | PASS |
|
|
Please call Brian at ###-#### 30 min prior so he can meet the inspector on site to let him in. Phone #: ###-#### Inspection requested via web by Ashley Shoecraft - final ok
|
MEC19-04367
| Final | 10/2/2019 | 10/3/2019 | 10/3/2019 1:27:09 PM | P | PASS |
|
|
Dan ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - A/C coil co ok
|
MEC19-04097
| Rough-in | 10/2/2019 | 10/3/2019 | 10/3/2019 12:13:18 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - need stamped man J onsite - return air for both furnaces not per prints - fresh air needs to tap off furnace return plenum not return can - water heater 5lb flue fail
|
MEC19-04097
| Pressure Test | 10/2/2019 | 10/3/2019 | 10/3/2019 12:10:44 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - 5lb flue for furnace ok - 20lb and 60lb gas pressure test ok - tagged meter location - water heater 5lb flue test fail under 5lb
|
MEC19-03819
| Final | 10/3/2019 | 10/3/2019 | 10/3/2019 12:09:26 PM | P | FAIL |
|
|
Call Emma in route to inspection ###-####--she may not be home but corrections are visible from outside of home. Phone #: ###-#### Inspection requested via web by Justin Osterhout - still need to see an electrical permit pulled for ductless system
|
MEC19-02782
| Final | 10/3/2019 | 10/3/2019 | 10/3/2019 11:43:44 AM | P | PASS |
|
|
Michael Phone #: ###-#### - final ok
|
MEC19-04112
| Final | 10/2/2019 | 10/3/2019 | 10/3/2019 11:42:47 AM | P | PASS |
|
|
Electrical permit has been pulled for the A/C install. ELEC19-03736 Please call Home owner at ###-#### if you need access inside house. Phone #: ###-#### Inspection requested via web by terry Warden - final ok
|
MEC19-01963
| Final | 10/2/2019 | 10/3/2019 | 10/3/2019 10:47:43 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Sheldon Lebow
- fireplace final ok
|
MEC19-02186
| Final | 10/1/2019 | 10/3/2019 | 10/3/2019 10:31:09 AM | A | PASS |
|
|
access code for entry should be 4224 or 2529 Phone #: ###-#### Inspection requested via web by Angie Maguire - final ok
|
MEC19-04389
| Rough-in | 10/2/2019 | 10/3/2019 | 10/3/2019 10:05:52 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Sheldon Lebow - fireplace R/I ok
|
MEC19-04385
| Final | 10/2/2019 | 10/3/2019 | 10/3/2019 9:34:34 AM | A | FAIL |
|
|
Replace existing furnace with a new furnace. Added a air conditioner. Phone #: ###-#### Inspection requested via web by jeremy wanders - need locking caps on A/C service ports - need to seal line set penetration - electrical wiring to furnace is touching b vent and needs terminated properly at furnace -secondary drain needs a wet switch installed - vent piping from furnace needs slope with out dips and sags - natural draft needs to connect at highest point in common vent above fan assist appliance
|
MEC19-02272
| Final | 10/1/2019 | 10/3/2019 | 10/3/2019 8:46:35 AM | A | PASS |
|
|
please call john 30 min prior to arriving so he can meet you onsite thanks Phone #: ###-#### Inspection requested via web by Nicholas Paige - final ok signed occ card - talked with John about pulling a seperate mech permit for the shell gas piping and two unit heaters
|