Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-02809 ELE-Aging Inspection10/30/200610/30/200610/31/2006 10:29:49 AM NR
could not find sign
ELE06-03495 Final10/30/200610/30/200610/30/2006 4:13:59 PMPPART
jason ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith need perm panel schedules, perm labels for service, core and shell not done
ELE06-00460 Final10/30/200610/30/200610/30/2006 4:12:26 PMPPART
duke - note: ceiling ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith bld not final, still has to wire front entry fountain, provide perm panel schedules, panel legends, strap mc in stairwells, rest ok, told need address posted
ELE06-03550 Final10/30/200610/30/200610/30/2006 4:10:43 PMPPART
jason - note: ceiling ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok to cover ceilings, fa still being installed, core and shell not done, need hw heater disc, need panel schedules and perm label
ELE06-03494 Final10/30/200610/30/200610/30/2006 4:08:56 PMPPART
jason ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith core and shell not done, need hw heater disc, panel schedules, labels for service disc
ELE06-00460 Electrical Rough-In10/30/200610/30/200610/30/2006 4:03:47 PMPPASS
duke - note: ceiling ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ceilings ok to cover halls and stairways
ELE06-03966 Permanent Service10/30/200610/30/200610/30/2006 3:10:11 PMPPASS
robert; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s o/h n ok
ELE06-03905 Electrical Rough-In10/30/200610/30/200610/30/2006 3:09:43 PMPPART
hz; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ric upper level only ok
ELE06-03475 Rough-In Permanent Service10/30/200610/30/200610/30/2006 1:09:52 PMPCANC
Scheduled by a contractor via Hello! on 10/30/2006 at 9:09:05 AM. Contact: ###-####. owner needing u/g inspection for ipco service to new meter on shop. u/g is 30" deep , less than 360 degree bend. 370 suggested owner contact ipco before cover
ELE06-03821 Final10/27/200610/30/200610/30/2006 12:03:59 PMAPASS
curtis - note: call for access ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith corr made, ok to final
ELE06-03275 Electrical Rough-In10/30/200610/30/200610/30/2006 10:15:04 AMAPART
Scheduled by a contractor via Hello! on 10/30/2006 at 6:53:51 AM. Contact: ###-####. lobby walls and clg, bakery ceiling ok to cover
ELE06-03928 Conference10/24/200610/30/200610/30/2006 9:10:29 AMADONE
kevin; Phone #: ###-#### - note: call 1/2 hr prior to going out - Internet Inspection Request from: Patricia Smith reviewed amount of upgrade req'd to rewire house and service location, floor boxes, gfci to replace 2 wire recpts
ELE06-03649 Electrical Rough-In10/27/200610/30/200610/30/2006 9:02:52 AMAPASS
brandon- note: underground ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith told contr to check w power co about incoming power conduit depth, ok to cover 1 1/4 to garage, did not leave sticker, said done electronically
ELE05-01204 Electrical Rough-In10/27/200610/30/200610/30/2006 8:18:51 AMAPASS
michale; Phone #: ###-#### Note: if possible between 8:00 - 9:00 Internet Inspection Request from: Cathy Chiles met owner, told and gave list to put in ko seals, strap nm cable over panel, isolate gnd in panel, provide 4 wire recpt for dryer, nail plates 3 plcs, gave ok to cover, check panel at final