ELE06-02809
| ELE-Aging Inspection | 10/30/2006 | 10/30/2006 | 10/31/2006 10:29:49 AM | | NR |
|
|
could not find sign
|
ELE06-03495
| Final | 10/30/2006 | 10/30/2006 | 10/30/2006 4:13:59 PM | P | PART |
|
|
jason ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith need perm panel schedules, perm labels for service, core and shell not done
|
ELE06-00460
| Final | 10/30/2006 | 10/30/2006 | 10/30/2006 4:12:26 PM | P | PART |
|
|
duke - note: ceiling ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith bld not final, still has to wire front entry fountain, provide perm panel schedules, panel legends, strap mc in stairwells, rest ok, told need address posted
|
ELE06-03550
| Final | 10/30/2006 | 10/30/2006 | 10/30/2006 4:10:43 PM | P | PART |
|
|
jason - note: ceiling ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok to cover ceilings, fa still being installed, core and shell not done, need hw heater disc, need panel schedules and perm label
|
ELE06-03494
| Final | 10/30/2006 | 10/30/2006 | 10/30/2006 4:08:56 PM | P | PART |
|
|
jason ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith core and shell not done, need hw heater disc, panel schedules, labels for service disc
|
ELE06-00460
| Electrical Rough-In | 10/30/2006 | 10/30/2006 | 10/30/2006 4:03:47 PM | P | PASS |
|
|
duke - note: ceiling ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ceilings ok to cover halls and stairways
|
ELE06-03966
| Permanent Service | 10/30/2006 | 10/30/2006 | 10/30/2006 3:10:11 PM | P | PASS |
|
|
robert; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s o/h n ok
|
ELE06-03905
| Electrical Rough-In | 10/30/2006 | 10/30/2006 | 10/30/2006 3:09:43 PM | P | PART |
|
|
hz; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ric upper level only ok
|
ELE06-03475
| Rough-In Permanent Service | 10/30/2006 | 10/30/2006 | 10/30/2006 1:09:52 PM | P | CANC |
|
|
Scheduled by a contractor via Hello! on 10/30/2006 at 9:09:05 AM. Contact: ###-####. owner needing u/g inspection for ipco service to new meter on shop. u/g is 30" deep , less than 360 degree bend. 370 suggested owner contact ipco before cover
|
ELE06-03821
| Final | 10/27/2006 | 10/30/2006 | 10/30/2006 12:03:59 PM | A | PASS |
|
|
curtis - note: call for access ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith corr made, ok to final
|
ELE06-03275
| Electrical Rough-In | 10/30/2006 | 10/30/2006 | 10/30/2006 10:15:04 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 10/30/2006 at 6:53:51 AM. Contact: ###-####. lobby walls and clg, bakery ceiling ok to cover
|
ELE06-03928
| Conference | 10/24/2006 | 10/30/2006 | 10/30/2006 9:10:29 AM | A | DONE |
|
|
kevin; Phone #: ###-#### - note: call 1/2 hr prior to going out - Internet Inspection Request from: Patricia Smith reviewed amount of upgrade req'd to rewire house and service location, floor boxes, gfci to replace 2 wire recpts
|
ELE06-03649
| Electrical Rough-In | 10/27/2006 | 10/30/2006 | 10/30/2006 9:02:52 AM | A | PASS |
|
|
brandon- note: underground ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith told contr to check w power co about incoming power conduit depth, ok to cover 1 1/4 to garage, did not leave sticker, said done electronically
|
ELE05-01204
| Electrical Rough-In | 10/27/2006 | 10/30/2006 | 10/30/2006 8:18:51 AM | A | PASS |
|
|
michale; Phone #: ###-#### Note: if possible between 8:00 - 9:00 Internet Inspection Request from: Cathy Chiles met owner, told and gave list to put in ko seals, strap nm cable over panel, isolate gnd in panel, provide 4 wire recpt for dryer, nail plates 3 plcs, gave ok to cover, check panel at final
|