Inspections for the day of: Tuesday, October 30, 2007.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03636 ELE-Aging Inspection10/30/200710/30/200710/31/2007 2:46:02 PM DONE
looked at sign, corrections not made, see fee due
ELE07-02712 Conference10/30/200710/30/200710/30/2007 3:43:08 PMPCANC
Underground pipe inspection. Phone #: ###-#### Internet Inspection Request from: Dan Rohl wrong type request, see ri
ELE07-02712 Electrical Rough-In10/30/200710/30/200710/30/2007 3:27:10 PMPPASS
Underground pipe inspection. Phone #: ###-#### Internet Inspection Request from: Dan Rohl ok to cover front side u/g only for parking lot lighting
ELE07-03664 Final10/30/200710/30/200710/30/2007 2:54:02 PMPCANC
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson wrong type inspection request
ELE07-03664 Electrical Rough-In10/30/200710/30/200710/30/2007 2:43:07 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson called contractor, left correction notice, NEC 210.53 shall provide receptacles per wall space provisions of (A)-1,2,3 (dining room, kitchen,upstairs),300.4(D) nm cable shall be 1 1/4" from edge of framing members, BCC all make-up shall be done- boxes provided, jetted tub set
ELE07-03664 Permanent Service10/30/200710/30/200710/30/2007 2:09:26 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson p/s u/g n ok
ELE07-03551 Permanent Service10/30/200710/30/200710/30/2007 2:07:39 PMPPASS
Scheduled by a contractor via Hello! on 10/30/2007 at 10:10:15 AM. Contact: ###-####. contractor found concrete encased electrode, p/s u/g n ok
ELE07-03371 Final10/29/200710/30/200710/30/2007 1:17:43 PMPPASS
please call prior to inspection thank you Brad Phone #: ###-#### Internet Inspection Request from: Brad Baker ok to final
ELE07-03369 Final10/29/200710/30/200710/30/2007 12:30:08 PMPPASS
please call prior to inspection thank you Brad Phone #: ###-#### Internet Inspection Request from: Brad Baker ok to final
ELE07-03656 Conference10/29/200710/30/200710/30/2007 11:19:48 AMADONE
###-####- eldon- call 1st before insp talked about when to call for inspection, make-up, free conductor length, circuits, 1 1/4", outlet spacing
ELE07-02297 Permanent Service10/29/200710/30/200710/30/2007 9:52:25 AMAPASS
Contact is Jay Phone #: ###-#### Internet Inspection Request from: Richard Montgomery correction made, ok to cover u/g, p/s u/g n ok
ELE07-03085 Final10/29/200710/30/200710/30/2007 8:46:04 AMAPASS
Scheduled by a contractor via Hello! on 10/29/2007 at 3:47:57 PM. Contact: ###-####. ok to final, called contractor