Inspections for the day of: Friday, October 30, 2015.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Little
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM15-03227 Plumbing Rough-in10/29/201510/30/201510/30/2015 4:09:45 PMPFAIL
Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
>need c/o on foot vent
>backgraded vent upstairs
>two crimp rings on pex not per manf. installation stnd. at water service ftg.
>retest
PLM15-03226 Plumbing Rough-in10/29/201510/30/201510/30/2015 4:08:48 PMPFAIL
Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
>two crimp rings on pex not per manf. installation stnd. at water service ftg.
>need c/o on foot vent and nail plates
>retest
PLM14-02393 PLM-Aging Inspection10/30/201510/30/201510/30/2015 3:32:40 PM FAIL
no calls
PLM15-02221 DOC - Permit Finaled10/30/201510/30/201510/30/2015 3:28:56 PMPPASS
PLM15-02221 PLM-Aging Inspection10/30/201510/30/201510/30/2015 3:28:40 PM PASS
work by different contractor
PLM15-03756 Plumbing Rough-in10/30/201510/30/201510/30/2015 3:01:32 PMPPASS
Phone #: ###-#### Inspection requested via web by Rob Bristol
PLM15-03746 DOC - Permit Finaled10/30/201510/30/201510/30/2015 2:42:57 PMPPASS
PLM15-03746 Water and/or Sewer10/29/201510/30/201510/30/2015 2:42:40 PMPPASS
Water, Sewer Phone #: ###-#### Inspection requested via web by Darren Wood
PLM15-03747 Water and/or Sewer10/29/201510/30/201510/30/2015 2:41:55 PMPFAIL
Water, Sewer Phone #: ###-#### Inspection requested via web by Darren Wood
>pvc joints not glued properly, pipe still has the plastic on it where it is glued at a joint, joint at combo is broke loose as well.
PLM15-03745 DOC - Permit Finaled10/30/201510/30/201510/30/2015 1:50:17 PMPPASS
PLM15-03745 Water and/or Sewer10/29/201510/30/201510/30/2015 1:49:56 PMPPASS
Water, Sewer Phone #: ###-#### Inspection requested via web by Darren Wood
PLM15-03757 Groundwork10/30/201510/30/201510/30/2015 11:32:19 AMPPASS
if questions call Steve @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
PLM15-01371 Final10/29/201510/30/201510/30/2015 11:11:56 AMAPART
DAVID IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
>signed temp
>need airgap at t&p showroom wh
>move expansion tank or check valve on service are wh.
>install missing sink
>label rp to mau's
>remove pvc at ro in carwash and replace with approved material.
>prove lav faucets are ASSE 1070 approved.
PLM15-01723 Other10/29/201510/30/201510/30/2015 9:48:06 AMADONE
meet Stacy from united water on hose bibbs 9:00.
>Stacey is requiring rpba on hose bibbs in shop, vertical rpba's ok if approved.
PLM15-03751 Water Heater Final10/29/201510/30/201510/29/2015 4:02:34 PMAPASS
William Phone #: ###-####
PLM15-03740 Water and/or Sewer10/29/201510/30/201510/29/2015 11:43:10 AMACANC
Phone #: ###-#### >> Inspection requested via web by Vicki Tallent Inspection cancelled from web by: Vicki Tallent