MEC18-05073
| Final | 10/23/2018 | 10/30/2018 | 10/30/2018 4:09:06 PM | P | PASS |
|
|
please call homeowners Richard or Elvia when 30 mins in route Phone #: ###-#### Inspection requested via web by Rick Montgomery- furnace co ok
|
MEC18-05168
| Final | 10/26/2018 | 10/30/2018 | 10/30/2018 3:37:29 PM | P | NH |
|
|
Please call homeowner 30 minutes in advance for access at ###-#### and call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Lea Briggs- called number listed no answer- went by no one home
|
MEC18-05210
| Final | 10/30/2018 | 10/30/2018 | 10/30/2018 3:20:57 PM | P | PASS |
|
|
|
MEC18-05210
| Pressure Test | 10/29/2018 | 10/30/2018 | 10/30/2018 3:20:08 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by anthony allen- 20lb gas pass to range- co installed
|
MEC18-05216
| Conference | 10/30/2018 | 10/30/2018 | 10/30/2018 2:50:41 PM | P | PASS |
|
|
please call mark at number above we need to have a duct sealer inspection so we can insulate Phone #: ###-#### Inspection requested via web by Brandon Sorensen- seal on duct ok- ok to insulate- design build no prints added zone system and 5 office spaces with transfer registers
|
MEC18-04323
| Rough-in | 10/30/2018 | 10/30/2018 | 10/30/2018 2:29:10 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kim Evans- bath exhaust 2nd floor pinched off- b vent at roof needs 1" clearance to combustibles- seal 2 boots 1st floor- frame out dryer duct and install nail plate at ceiling- wyes need insulated 1st floor- left correction notice first floor bedroom window
|
MEC18-05192
| Final | 10/29/2018 | 10/30/2018 | 10/30/2018 2:05:23 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
MEC18-04318
| Rough-in | 10/26/2018 | 10/30/2018 | 10/30/2018 1:45:22 PM | P | PART |
|
|
Please call Luke 30 mins ahead so that he can get you access Phone #: ###-#### Inspection requested via web by Melissa - R/i ok- need to seal weather tight and support ducting on roof- will look at exhaust fans at final- ok for cover- plumbing vent needs to be 10 feet away or 3 feet higher than economizer on roof
|
MEC18-05048
| Pressure Test | 10/24/2018 | 10/30/2018 | 10/30/2018 1:13:43 PM | P | PASS |
|
|
installer Al ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pass- tagged gas pipe at meter
|
MEC18-05208
| Pressure Test | 10/30/2018 | 10/30/2018 | 10/30/2018 12:34:51 PM | P | PASS |
|
|
20lb gas pass from meter to range location
|
MEC18-04368
| Rough-in | 10/29/2018 | 10/30/2018 | 10/30/2018 11:42:52 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer- need approved city manual J onsite-
|
MEC18-04368
| Pressure Test | 10/29/2018 | 10/30/2018 | 10/30/2018 11:36:46 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer- gauge at zero
|
MEC18-05198
| Rough-in | 10/29/2018 | 10/30/2018 | 10/30/2018 10:36:15 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft- plastic visqueen is touching back of fireplace and is laying on flue-
|
MEC18-05208
| Rough-in | 10/29/2018 | 10/30/2018 | 10/30/2018 10:09:01 AM | A | FAIL |
|
|
Please call when on the way. Thank you. Phone #: ###-#### Inspection requested via web by Jennifer Alcala- pressure was only from gauge to shutoff valve- whole system wasnt under pressure
|
MEC18-05062
| Pressure Test | 10/29/2018 | 10/30/2018 | 10/30/2018 9:47:46 AM | A | PASS |
|
|
Gas pressure test needed. Phone #: ###-#### Inspection requested via web by Lynn Johnston- 20lb gas pass- still need to look at R/A and dryer vent at final
|