MEC19-00220
| Final | 10/29/2019 | 10/30/2019 | 10/30/2019 3:45:12 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jared Wilson- furnace a/c coil co locking caps gas piping ok
|
MEC19-03375
| Final | 10/29/2019 | 10/30/2019 | 10/30/2019 3:23:07 PM | P | PASS |
|
|
Mechanical Gas Fireplace Final Inspection. Manual is in kitchen drawer right of stove. Please call Kelly @ ###-#### when heading there. Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace final ok
|
MEC19-01441
| Final | 10/30/2019 | 10/30/2019 | 10/30/2019 2:49:06 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Kelton Tackett- need electrical permit issued for electrical work on boiler- mec permit is attached to building permit from 2012- need to verify bld is right or did it need one- Talked with Kelton onsite he will check into this and let me know- Boiler and gas piping ok- will final out once issues have been resolved
|
MEC19-03852
| Final | 10/30/2019 | 10/30/2019 | 10/30/2019 2:19:21 PM | P | FAIL |
|
|
Jake is the contact Phone #: ###-#### Inspection requested via web by stan lillquist- 1- need roof access fire riser room locked up 2- need to remove all ceiling tiles around register to finish R/I inspection on insulation duct and registers and have ladder onsite for inspection
|
MEC19-04801
| Rough-in | 10/29/2019 | 10/30/2019 | 10/30/2019 1:58:42 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- need to seal all R/A boots- need to seal dryer duct to termination box
|
MEC19-04801
| Pressure Test | 10/29/2019 | 10/30/2019 | 10/30/2019 1:57:17 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location
|
MEC19-02591
| Rough-in | 10/30/2019 | 10/30/2019 | 10/30/2019 1:30:19 PM | P | FAIL |
|
|
Ceiling cover for grid ceiling installation Phone #: ###-#### Inspection requested via web by Robin Cox- rm 142 needs supply duct hooked up to register- rm 109 needs flex ducting supported off grid- rm116 need supply duct supported off grid- rm 130a need to verify that electrical closet is not getting an ceiling in it for transfer ducting wasnt shown on print to get enclosed around panel- Rest is good- still need to look at unit heaters and roof penetrations
|
MEC19-04817
| Final | 10/24/2019 | 10/30/2019 | 10/30/2019 12:47:24 PM | P | NR |
|
|
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- still installing- recall in when ready- went over onsite with Travis
|
MEC19-04817
| Pressure Test | 10/24/2019 | 10/30/2019 | 10/30/2019 12:46:01 PM | P | PASS |
|
|
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pass
|
MEC19-04037
| Rough-in | 10/29/2019 | 10/30/2019 | 10/30/2019 11:21:40 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok- need to seal R/A can where outside air was removed and patched by final- could not see if sealed on inside since filter was installed in can
|
MEC19-04037
| Pressure Test | 10/29/2019 | 10/30/2019 | 10/30/2019 11:20:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass- tagged meter location
|
MEC19-04546
| Rough-in | 10/29/2019 | 10/30/2019 | 10/30/2019 10:52:38 AM | A | FAIL |
|
|
GARI ###-#### MANUAL UNDER UNIT W/REMOTE Phone #: ###-#### Inspection requested via web by Mike Almanza- draft stop to flue does not have 1" clearance to combustible- offset inside chase doesnt have 1" clearance to vertical 2x4
|
MEC19-04137
| Final | 10/29/2019 | 10/30/2019 | 10/30/2019 10:25:05 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by RaChelle Frisbee- final ok- card signed- engineer approved relocation of RTU via stamped document
|
MEC19-02931
| Final | 10/29/2019 | 10/30/2019 | 10/30/2019 9:56:04 AM | A | FAIL |
|
|
Back door is open Phone #: ###-#### Inspection requested via web by Konrad Swartz- need locking caps on a/c service ports- rest is good
|
MEC19-01310
| Final | 10/28/2019 | 10/30/2019 | 10/30/2019 9:28:41 AM | A | PASS |
|
|
our techs will be on site by 8:30 to do necessary repairs. Will take approx. 1 hour. thank you!! Phone #: ###-#### Inspection requested via web by Denise Colin- a/c coil co locking caps ok
|
MEC19-04688
| Final | 10/23/2019 | 10/30/2019 | 10/30/2019 8:53:06 AM | A | PASS |
|
|
Please call prior Ray or Viola Martin ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace only co ok
|
MEC19-04492
| Final | 10/30/2019 | 10/30/2019 | 10/30/2019 8:17:04 AM | A | FAIL |
|
|
early as possible- ###-####- furnace a/c coil co ok- need locking caps on a/c service ports- send pic for reinspect
|
MEC18-05961
| Mec-Aging Inspection | 10/30/2019 | 10/30/2019 | 10/30/2019 7:51:11 AM | | FAIL |
|
|
contractor needs to schedule inspection- bld still open- permit will expire next aging
|
MEC18-04405
| Mec-Aging Inspection | 10/30/2019 | 10/30/2019 | 10/30/2019 7:50:07 AM | | CANC |
|
|
no calls- no activity- bld still open- contractor needs to schedule final
|
MEC18-05831
| Mec-Aging Inspection | 10/30/2019 | 10/30/2019 | 10/30/2019 7:47:52 AM | | CANC |
|
|
|
MEC18-05831
| DOC - Permit Expired | 10/30/2019 | 10/30/2019 | 10/30/2019 7:47:45 AM | A | PASS |
|
|
no calls- no activity
|
MEC19-03757
| Final | 10/29/2019 | 10/30/2019 | 10/29/2019 2:02:48 PM | A | CANC |
|
|
ANY QUESTIONS YOU CAN CALL SAM THE PROJECT MANAGER ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
|