MEC19-04865
| Final | 10/30/2019 | 10/30/2019 | 10/30/2019 3:37:55 PM | P | PASS |
|
|
We will be sending you pictures of a correction that we''re making this PM. Phone #: ###-#### Inspection requested via web by Arielle Hendricks
|
MEC19-04816
| Final | 10/24/2019 | 10/30/2019 | 10/30/2019 2:37:31 PM | P | PASS |
|
|
INSTALLER DAKOTA ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
MEC19-04552
| Rough-in | 10/30/2019 | 10/30/2019 | 10/30/2019 2:03:58 PM | P | NH |
|
|
Mechanical Gas Fireplace Rough-In Inspection Phone #: ###-#### Inspection requested via web by Dan Otero - no access -
|
MEC19-04760
| DOC - Permit Finaled | 10/30/2019 | 10/30/2019 | 10/30/2019 1:57:56 PM | P | PASS |
|
|
|
MEC19-04882
| Rough-in | 10/30/2019 | 10/30/2019 | 10/30/2019 1:40:08 PM | P | NH |
|
|
Furnace will have enough space after tankless water heater is installed. Phone #: ###-#### Inspection requested via web by Jose Lagunas - no access -
|
MEC19-02754
| Final | 10/30/2019 | 10/30/2019 | 10/30/2019 1:29:10 PM | P | PASS |
|
|
field super: Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC19-02564
| Final | 10/30/2019 | 10/30/2019 | 10/30/2019 1:23:21 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Aaron Alandt - water heater bvent doesnt have clearence to floor joist - - condencer needs locking caps -
|
MEC19-04870
| Rough-in | 10/28/2019 | 10/30/2019 | 10/30/2019 11:45:51 AM | A | FAIL |
|
|
PLEASE CALL CONTRACTOR JOSH WHEN IN ROUTE- READY FOR ROUGH IN INSPECTION Phone #: ###-#### Inspection requested via web by Rick Montgomery - bvent needs insulation shield -
|
MEC19-04870
| Pressure Test | 10/28/2019 | 10/30/2019 | 10/30/2019 11:45:27 AM | A | PASS |
|
|
PLEASE CALL CONTRACTOR JOSH WHEN IN ROUTE, LINE WILL BE UNDER PRESSURE AND READY FOR YOU TO INSPECT. Phone #: ###-#### Inspection requested via web by Rick Montgomery - 20lb x2, in building and underground -
|
MEC19-04842
| Pressure Test | 10/29/2019 | 10/30/2019 | 10/30/2019 10:23:22 AM | A | PASS |
|
|
pressure witness Phone #: ###-#### Inspection requested via web by Cesar Rodriguez - 20lb -
|
MEC19-04842
| DOC - Permit Finaled | 10/30/2019 | 10/30/2019 | 10/30/2019 10:22:51 AM | P | PASS |
|
|
|
MEC19-04851
| Pressure Test | 10/29/2019 | 10/30/2019 | 10/30/2019 9:47:00 AM | A | FAIL |
|
|
Pressure test for a new gas line for a range. Contractor will be close by to open door. Phone ###-#### Phone #: ###-#### Inspection requested via web by Nicolas Barajas - test at 3.5 lbs -
|
MEC19-04676
| Final | 10/28/2019 | 10/30/2019 | 10/30/2019 9:26:34 AM | A | PASS |
|
|
Please call Amanda in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout
|
MEC18-05132
| Mec-Aging Inspection | 10/30/2019 | 10/30/2019 | 10/30/2019 8:38:05 AM | | CANC |
|
|
still working
|