ELE07-03676
| Final | 10/31/2007 | 10/31/2007 | 10/31/2007 3:20:29 PM | P | PASS |
|
|
###-#### Internet Inspection Request from: Todd Holbrook called contractor, ok to final
|
ELE07-03677
| Permanent Service | 10/31/2007 | 10/31/2007 | 10/31/2007 2:36:07 PM | P | PASS |
|
|
andy Phone #: ###-#### p/s o/h rec ok
|
ELE07-03563
| Final | 10/31/2007 | 10/31/2007 | 10/31/2007 1:56:46 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called contractor, left message, left correction notice,BCC no ceiling tiles shall be installed prior to inspection, no violations shall be retained
|
ELE07-02784
| Electrical Rough-In | 10/31/2007 | 10/31/2007 | 10/31/2007 1:22:21 PM | P | CANC |
|
|
chris Phone #: ###-#### called contractor, wrong type request, see p/s
|
ELE07-02784
| Permanent Service | 10/31/2007 | 10/31/2007 | 10/31/2007 12:55:27 PM | P | PASS |
|
|
chris Phone #: ###-#### called contractor to id addresses on meter pak, p/s, exst meter pak, n, ok, 1 meter this permit only
|
ELE07-03680
| Rough-In Permanent Service | 10/31/2007 | 10/31/2007 | 10/31/2007 12:51:51 PM | P | PASS |
|
|
Obn-site contact = Jerry ###-#### Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ric ok walls and hard lids only, p/s, exst meter pak, n, ok, 2 meters
|
ELE07-03636
| Electrical Rough-In | 10/31/2007 | 10/31/2007 | 10/31/2007 10:51:02 AM | A | PASS |
|
|
Light is GFI protected in bedroom. Call if you need access into home to check. Access back yard through gate on south side of home Phone #: ###-#### Internet Inspection Request from: Cevyn Recla saw job for u/g earlier, don't see notes, but still ok for ri, see final
|
ELE07-03636
| Final | 10/31/2007 | 10/31/2007 | 10/31/2007 10:34:23 AM | A | PASS |
|
|
Light is GFI protected in bedroom. Call if you need access into home to check. Access back yard through gate on south side of home Phone #: ###-#### Internet Inspection Request from: Cevyn Recla ok to final
|
ELE07-03370
| Electrical Rough-In | 10/30/2007 | 10/31/2007 | 10/31/2007 10:15:56 AM | A | CANC |
|
|
KEVIN Phone #: ###-#### wrong type inspection request, see final
|
ELE07-03370
| Final | 10/31/2007 | 10/31/2007 | 10/31/2007 10:15:35 AM | P | PASS |
|
|
KEVIN Phone #: ###-#### kevin doesn't work there, called mike at B&B, said ok to final, therefore ok to final
|
ELE07-02461
| Final | 10/30/2007 | 10/31/2007 | 10/31/2007 10:03:18 AM | A | PASS |
|
|
House final, also inspect trench between house and pump house. We will take out a separate permit for pump house. Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot called contractor, u/g house to pump house only ok to cover, ok to final house
|
ELE07-03648
| Permanent Service | 10/30/2007 | 10/31/2007 | 10/31/2007 9:52:01 AM | A | PASS |
|
|
CHRIS nOTE: ALSO PANEL Phone #: ###-#### p/s u/g n ok, 1 meter
|
ELE07-03446
| Final | 10/30/2007 | 10/31/2007 | 10/31/2007 9:04:25 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called, left message, left correction notice, nec 110.12(A) unused openings shall be closed, 110.26(A)(1) shall clear workspace in front of panel, 312.5 all conductors entering enclosures shall have abrasion protection, 408.38 shall provide deadfront 408.4 shall provide circuit directory, 314.25 boxes shall have covers installed, 406.8(B) shall use in-use covers- installed, 110.3(B) listed equipment shall be installed per manufacturers instructions and operate correctly
|