Inspections for the day of: Wednesday, October 31, 2007.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-03676 Final10/31/200710/31/200710/31/2007 3:20:29 PMPPASS
###-#### Internet Inspection Request from: Todd Holbrook called contractor, ok to final
ELE07-03677 Permanent Service10/31/200710/31/200710/31/2007 2:36:07 PMPPASS
andy Phone #: ###-#### p/s o/h rec ok
ELE07-03563 Final10/31/200710/31/200710/31/2007 1:56:46 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called contractor, left message, left correction notice,BCC no ceiling tiles shall be installed prior to inspection, no violations shall be retained
ELE07-02784 Electrical Rough-In10/31/200710/31/200710/31/2007 1:22:21 PMPCANC
chris Phone #: ###-#### called contractor, wrong type request, see p/s
ELE07-02784 Permanent Service10/31/200710/31/200710/31/2007 12:55:27 PMPPASS
chris Phone #: ###-#### called contractor to id addresses on meter pak, p/s, exst meter pak, n, ok, 1 meter this permit only
ELE07-03680 Rough-In Permanent Service10/31/200710/31/200710/31/2007 12:51:51 PMPPASS
Obn-site contact = Jerry ###-#### Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ric ok walls and hard lids only, p/s, exst meter pak, n, ok, 2 meters
ELE07-03636 Electrical Rough-In10/31/200710/31/200710/31/2007 10:51:02 AMAPASS
Light is GFI protected in bedroom. Call if you need access into home to check. Access back yard through gate on south side of home Phone #: ###-#### Internet Inspection Request from: Cevyn Recla saw job for u/g earlier, don't see notes, but still ok for ri, see final
ELE07-03636 Final10/31/200710/31/200710/31/2007 10:34:23 AMAPASS
Light is GFI protected in bedroom. Call if you need access into home to check. Access back yard through gate on south side of home Phone #: ###-#### Internet Inspection Request from: Cevyn Recla ok to final
ELE07-03370 Electrical Rough-In10/30/200710/31/200710/31/2007 10:15:56 AMACANC
KEVIN Phone #: ###-#### wrong type inspection request, see final
ELE07-03370 Final10/31/200710/31/200710/31/2007 10:15:35 AMPPASS
KEVIN Phone #: ###-#### kevin doesn't work there, called mike at B&B, said ok to final, therefore ok to final
ELE07-02461 Final10/30/200710/31/200710/31/2007 10:03:18 AMAPASS
House final, also inspect trench between house and pump house. We will take out a separate permit for pump house. Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot called contractor, u/g house to pump house only ok to cover, ok to final house
ELE07-03648 Permanent Service10/30/200710/31/200710/31/2007 9:52:01 AMAPASS
CHRIS nOTE: ALSO PANEL Phone #: ###-#### p/s u/g n ok, 1 meter
ELE07-03446 Final10/30/200710/31/200710/31/2007 9:04:25 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called, left message, left correction notice, nec 110.12(A) unused openings shall be closed, 110.26(A)(1) shall clear workspace in front of panel, 312.5 all conductors entering enclosures shall have abrasion protection, 408.38 shall provide deadfront 408.4 shall provide circuit directory, 314.25 boxes shall have covers installed, 406.8(B) shall use in-use covers- installed, 110.3(B) listed equipment shall be installed per manufacturers instructions and operate correctly