ELE08-01522
| ELE-Aging Inspection | 10/31/2008 | 10/31/2008 | 11/3/2008 9:43:22 AM | | PART |
|
|
see added conf
|
ESC06-01224
| General Inspection | 10/31/2008 | 10/31/2008 | 10/31/2008 3:38:53 PM | P | PASS |
|
|
site ok still needs some type of cover for yard , for final but some landscaping work has started
|
ELE08-02913
| Final | 10/31/2008 | 10/31/2008 | 10/31/2008 3:36:26 PM | P | PASS |
|
|
rick Phone #: ###-#### ok
|
ELE08-02906
| Rough-In Permanent Service | 10/31/2008 | 10/31/2008 | 10/31/2008 3:36:06 PM | P | PASS |
|
|
daniel Phone #: ###-#### called needs outlet wall right of pantry door, told contr about clearence for all closet fixtures r/i p/s u/g new ok
|
ESC08-00766
| General Inspection | 10/31/2008 | 10/31/2008 | 10/31/2008 2:24:16 PM | P | PASS |
|
|
ok
|
ELE08-02936
| Electrical Rough-In | 10/31/2008 | 10/31/2008 | 10/31/2008 2:23:38 PM | P | PASS |
|
|
larry Phone #: ###-#### r/i ok
|
ESC08-00762
| General Inspection | 10/31/2008 | 10/31/2008 | 10/31/2008 1:43:43 PM | P | PASS |
|
|
site ok
|
ELE08-02870
| Rough-In Permanent Service | 10/31/2008 | 10/31/2008 | 10/31/2008 1:42:55 PM | P | NR |
|
|
Scheduled by a contractor via Hello! on 10/31/2008 at 7:00:00 AM. Contact: ###-####. called nedds allwiring complete, needs concrete encased electrode, needs jtub installed
|
ELE08-02922
| Rough-In Permanent Service | 10/31/2008 | 10/31/2008 | 10/31/2008 12:51:11 PM | P | FAIL |
|
|
###-#### Internet Inspection Request from: Todd Holbrook called all violations not corrected and new violations created 250.8 shall use machine type screws for grd and bonds equip grd bus jbox, nail plates and 11/4" for cables parallel, seal all unsed KOs, 334.30 staple cables within 12" of boxes and cabibets
|
ELE08-01982
| ELE-Aging Inspection | 10/31/2008 | 10/31/2008 | 10/31/2008 11:41:49 AM | | DONE |
|
|
|
ELE08-01982
| Final | 10/31/2008 | 10/31/2008 | 10/31/2008 11:41:40 AM | A | PASS |
|
|
|
ELE08-01307
| ELE-Aging Inspection | 10/31/2008 | 10/31/2008 | 10/31/2008 11:40:25 AM | | PART |
|
|
wsuc
|
ESC08-00030
| General Inspection | 10/31/2008 | 10/31/2008 | 10/31/2008 10:46:05 AM | A | PASS |
|
|
site ok
|
ELE08-00108
| Final | 10/30/2008 | 10/31/2008 | 10/31/2008 10:45:14 AM | A | PASS |
|
|
brian Phone #: ###-#### ok
|
ELE08-02884
| Electrical Rough-In | 10/30/2008 | 10/31/2008 | 10/31/2008 9:59:55 AM | A | PART |
|
|
Good morning Bob, We need a wall\cover inspection for this T\I, there will be a small area that is not ready, waiting on electrical panel and lighting control panel, but the rest of the tenant space should be ready. Please call if you need directions. Thx. Wayne P.S. The phone number listed is my onsite foreman Blake. Phone #: ###-#### Internet Inspection Request from: Wayne Craig walls ok
|
ELE08-02410
| Electrical Rough-In | 10/30/2008 | 10/31/2008 | 10/31/2008 9:18:06 AM | A | PART |
|
|
wall rough-in in restroom Phone #: ###-#### Internet Inspection Request from: Celinda Winters ok
|
ELE08-02465
| Electrical Rough-In | 10/30/2008 | 10/31/2008 | 10/31/2008 8:41:07 AM | A | FAIL |
|
|
Starbucks coffee final inspection. Please call Kelly @ ###-#### Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson called told contr about violations on listed and labeled starbucks, I have done 2 other units both had same violations free length of conductors, boxes not grded, box fill (cutins), over 360 degree of bends in raceways and strapping within 12" of boxes for flex and MC note no access to inspect too many customers and employees at the starbucks
|
ELE08-02835
| Electrical Rough-In | 10/30/2008 | 10/31/2008 | 10/30/2008 3:03:35 PM | A | PART |
|
|
Shawn Phone #: ###-#### u/g is ID power u/g
|