Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01777 ELE-Aging Inspection10/31/201210/31/201211/6/2012 4:30:59 PM DONE
still under construction
ELE11-01790 ELE-Aging Inspection10/31/201210/31/201211/1/2012 2:53:22 PM DONE
Still waitiing on homeowner
ELE12-02679 Temporary Service10/31/201210/31/201210/31/2012 5:04:08 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn t/s u/g n ok
ELE12-02666 Permanent Service10/29/201210/31/201210/31/2012 4:16:19 PMPPASS
p/s u/g rec ok
ELE12-02666 Final10/31/201210/31/201210/31/2012 4:16:07 PMPPASS
p/s u/g rec ok Final ok
ELE12-02644 Electrical Rough-In10/31/201210/31/201210/31/2012 4:14:48 PMPPASS
Phone #: ###-#### >> Inspection requested via web by ERIC CENTERS wall rough in ok cover
ELE12-02645 Electrical Rough-In10/31/201210/31/201210/31/2012 3:59:29 PMPPASS
Phone #: ###-#### >> Inspection requested via web by ERIC CENTERS Wall rough in ok cover
ELE12-02564 Final10/31/201210/31/201210/31/2012 3:33:45 PMAPASS
Phone #: ###-#### >> Inspection requested via web by John VanZandt Final ok
ELE12-02247 Electrical Rough-In10/31/201210/31/201210/31/2012 3:19:05 PMPPASS
outdoor kitchen. walk around left side of house. thanks, dan Phone #: ###-#### >> Inspection requested via web by Dan Rohl Rough in ok cover
ELE12-02574 Rough-In Permanent Service10/30/201210/31/201210/31/2012 2:56:10 PMPCANC
inspection on concrete heat mats before concrete is poured and new 400amp service, any questions call andy @ ###-#### Phone #: ###-#### >> Inspection requested via web by Andy Rose Passed rough in of drive and service riser on cloned request
ELE12-02574 Electrical Rough-In10/31/201210/31/201210/31/2012 2:55:15 PMPPASS
inspection on concrete heat mats before concrete is poured and new 400amp service, any questions call andy @ ###-#### Phone #: ###-#### >> Inspection requested via web by Andy Rose Unerground service riser and driveway heat rough in ok cover
ELE12-02318 Electrical Rough-In10/31/201210/31/201210/31/2012 2:30:17 PMPPASS
WARM FLOOR RE-INSPECTION Phone #: ###-#### >> Inspection requested via web by Bob Glenn Floor heat rough in ok cover
ELE12-01375 Final10/31/201210/31/201210/31/2012 2:23:42 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI 1.Must have disconnect on upstairs furnace, 2. Light fixture located over shelf in upstairs closet/ furnace rm, 3. Front outdoor receptical must be weather resistant, 4. Vacuum receptical in garage must have GFCI protection, 5. Shop area off garage must have GFCI protection for recepticals, 6. Freezer receptical in garage must have GFCI protection, 7. All kitchen counter top recepticals must have GFCI protection, 8. Receptical in family room in-op, 9. Work clearance of 30" mustbe provided for AC disconnects, 10. White conductors used for phase conducors for ACs must be painted for entire length, 11. 30a breaker protecting 12 ga wire for AC.
ELE12-02255 Final10/30/201210/31/201210/31/2012 9:08:20 AMAPASS
code 1905 Phone #: ###-#### >> Inspection requested via web by kevin blackmon Final ok
ELE12-02676 Permanent Service10/30/201210/31/201210/30/2012 4:45:51 PMAPASS
The access code is 9569, thx. Phone #: ###-#### >> Inspection requested via web by Stephen Kren p/s u/g rec ok
ELE12-02318 Final10/30/201210/31/201210/30/2012 4:14:05 PMAFAIL
WARM FLOOR INSPECTION FOR MASTER BATHROOM Phone #: ###-#### >> Inspection requested via web by Bob Glenn Manufacturers instructions- recess factory splice in subfloor, recess sensor end in subfloor, nail plate lower plate.