ELE11-01777
| ELE-Aging Inspection | 10/31/2012 | 10/31/2012 | 11/6/2012 4:30:59 PM | | DONE |
|
|
still under construction
|
ELE11-01790
| ELE-Aging Inspection | 10/31/2012 | 10/31/2012 | 11/1/2012 2:53:22 PM | | DONE |
|
|
Still waitiing on homeowner
|
ELE12-02679
| Temporary Service | 10/31/2012 | 10/31/2012 | 10/31/2012 5:04:08 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE12-02666
| Permanent Service | 10/29/2012 | 10/31/2012 | 10/31/2012 4:16:19 PM | P | PASS |
|
|
p/s u/g rec ok
|
ELE12-02666
| Final | 10/31/2012 | 10/31/2012 | 10/31/2012 4:16:07 PM | P | PASS |
|
|
p/s u/g rec ok Final ok
|
ELE12-02644
| Electrical Rough-In | 10/31/2012 | 10/31/2012 | 10/31/2012 4:14:48 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by ERIC CENTERS wall rough in ok cover
|
ELE12-02645
| Electrical Rough-In | 10/31/2012 | 10/31/2012 | 10/31/2012 3:59:29 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by ERIC CENTERS Wall rough in ok cover
|
ELE12-02564
| Final | 10/31/2012 | 10/31/2012 | 10/31/2012 3:33:45 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by John VanZandt Final ok
|
ELE12-02247
| Electrical Rough-In | 10/31/2012 | 10/31/2012 | 10/31/2012 3:19:05 PM | P | PASS |
|
|
outdoor kitchen. walk around left side of house. thanks, dan Phone #: ###-#### >> Inspection requested via web by Dan Rohl Rough in ok cover
|
ELE12-02574
| Rough-In Permanent Service | 10/30/2012 | 10/31/2012 | 10/31/2012 2:56:10 PM | P | CANC |
|
|
inspection on concrete heat mats before concrete is poured and new 400amp service, any questions call andy @ ###-#### Phone #: ###-#### >> Inspection requested via web by Andy Rose Passed rough in of drive and service riser on cloned request
|
ELE12-02574
| Electrical Rough-In | 10/31/2012 | 10/31/2012 | 10/31/2012 2:55:15 PM | P | PASS |
|
|
inspection on concrete heat mats before concrete is poured and new 400amp service, any questions call andy @ ###-#### Phone #: ###-#### >> Inspection requested via web by Andy Rose Unerground service riser and driveway heat rough in ok cover
|
ELE12-02318
| Electrical Rough-In | 10/31/2012 | 10/31/2012 | 10/31/2012 2:30:17 PM | P | PASS |
|
|
WARM FLOOR RE-INSPECTION Phone #: ###-#### >> Inspection requested via web by Bob Glenn Floor heat rough in ok cover
|
ELE12-01375
| Final | 10/31/2012 | 10/31/2012 | 10/31/2012 2:23:42 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI 1.Must have disconnect on upstairs furnace, 2. Light fixture located over shelf in upstairs closet/ furnace rm, 3. Front outdoor receptical must be weather resistant, 4. Vacuum receptical in garage must have GFCI protection, 5. Shop area off garage must have GFCI protection for recepticals, 6. Freezer receptical in garage must have GFCI protection, 7. All kitchen counter top recepticals must have GFCI protection, 8. Receptical in family room in-op, 9. Work clearance of 30" mustbe provided for AC disconnects, 10. White conductors used for phase conducors for ACs must be painted for entire length, 11. 30a breaker protecting 12 ga wire for AC.
|
ELE12-02255
| Final | 10/30/2012 | 10/31/2012 | 10/31/2012 9:08:20 AM | A | PASS |
|
|
code 1905 Phone #: ###-#### >> Inspection requested via web by kevin blackmon Final ok
|
ELE12-02676
| Permanent Service | 10/30/2012 | 10/31/2012 | 10/30/2012 4:45:51 PM | A | PASS |
|
|
The access code is 9569, thx. Phone #: ###-#### >> Inspection requested via web by Stephen Kren p/s u/g rec ok
|
ELE12-02318
| Final | 10/30/2012 | 10/31/2012 | 10/30/2012 4:14:05 PM | A | FAIL |
|
|
WARM FLOOR INSPECTION FOR MASTER BATHROOM Phone #: ###-#### >> Inspection requested via web by Bob Glenn Manufacturers instructions- recess factory splice in subfloor, recess sensor end in subfloor, nail plate lower plate.
|