Inspections for the day of: Tuesday, October 31, 2017.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-02649 Electrical Rough-In10/30/201710/31/201710/31/2017 2:38:21 PMPPASS
Contact is Andy Chambers Phone #: ###-#### Inspection requested via web by Scott Campbell..

wall cover and ceiling grid as marked on plans..ok for perimeter grid cover...discussed clearances in electrical rm with existing equiment and not shutting down active hospital
ELE12-02127 ELE-Aging Inspection10/31/201710/31/201710/31/2017 1:50:18 PM FAIL
contractor making no attempt to schedule
ELE15-00917 Final10/27/201710/31/201710/31/2017 1:46:06 PMPPASS
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle...sign no longer there...out of business...ok to close permit
ELE17-03374 Electrical Rough-In10/30/201710/31/201710/31/2017 1:12:33 PMPPASS
EQ bonding plane wiring and connections Phone #: ###-#### Inspection requested via web by Lars Johnson...4 corners, cover, couplings for volleyball net, hot tub
ELE17-02866 Final10/30/201710/31/201710/31/2017 12:43:07 PMAPASS
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn..ok to final
ELE17-03555 Final10/31/201710/31/201710/31/2017 12:29:05 PMPPASS
Randy Phone #: ###-####...ok to final
ELE17-03669 Electrical Rough-In10/31/201710/31/201710/31/2017 12:07:56 PMPCANC
Phone #: ###-#### Inspection requested via web by Bryan Ellliott....wrong address given for location of work being done...in different inspectors area...contractor will need to reschedule and attach right address to permit
ELE17-03672 Permanent Service10/31/201710/31/201710/31/2017 11:41:52 AMPFAIL
White door to the left of meter main is open if you need to go in and no one lives there house is empty. Phone #: ###-#### Inspection requested via web by Jay Symonds...

address life safety issues before power can be turned on
1) overhead power to shop needs proper clearance 16' or removed
2) overhead power to house over deck needs proper clearances - 12'
3) exterior light fixture needs reinstalled or wires safed off
4) panel needs labelling
5) pond by service- GFI protection of power serving pond or completely removal of power
ELE17-03663 Final10/30/201710/31/201710/31/2017 10:50:05 AMACANC
Phone #: ###-#### Inspection requested via web by Mike Okamura...not ready...fixtures been removed
ELE17-03055 Final10/30/201710/31/201710/31/2017 10:17:28 AMAPASS
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn...ok to final
ELE17-02867 Final10/30/201710/31/201710/31/2017 9:51:28 AMAPASS
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn...ok to final
ELE17-03658 Temporary Service10/30/201710/31/201710/31/2017 9:26:42 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn...t/s u/g new ok
ELE17-03659 Temporary Service10/30/201710/31/201710/31/2017 9:19:06 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn...t/s u/g new ok
ELE17-03657 Temporary Service10/30/201710/31/201710/31/2017 9:00:23 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn...t/s u/g new ok
ELE17-03656 Temporary Service10/30/201710/31/201710/31/2017 8:41:04 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn...t/s u/g new ok
ELE17-03541 Permanent Service10/30/201710/31/201710/31/2017 8:29:43 AMAPASS
200 amp service Manufactured home Phone #: ###-#### Inspection requested via web by jamie berg...p/s u/g new ok
ELE15-01128 Final10/27/201710/31/201710/30/2017 8:40:16 AMPPASS
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle...ok to final
ELE15-00802 Final10/27/201710/31/201710/30/2017 8:39:49 AMPPASS
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle...ok to final