ELE17-02649
| Electrical Rough-In | 10/30/2017 | 10/31/2017 | 10/31/2017 2:38:21 PM | P | PASS |
|
|
Contact is Andy Chambers Phone #: ###-#### Inspection requested via web by Scott Campbell..
wall cover and ceiling grid as marked on plans..ok for perimeter grid cover...discussed clearances in electrical rm with existing equiment and not shutting down active hospital
|
ELE12-02127
| ELE-Aging Inspection | 10/31/2017 | 10/31/2017 | 10/31/2017 1:50:18 PM | | FAIL |
|
|
contractor making no attempt to schedule
|
ELE15-00917
| Final | 10/27/2017 | 10/31/2017 | 10/31/2017 1:46:06 PM | P | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle...sign no longer there...out of business...ok to close permit
|
ELE17-03374
| Electrical Rough-In | 10/30/2017 | 10/31/2017 | 10/31/2017 1:12:33 PM | P | PASS |
|
|
EQ bonding plane wiring and connections Phone #: ###-#### Inspection requested via web by Lars Johnson...4 corners, cover, couplings for volleyball net, hot tub
|
ELE17-02866
| Final | 10/30/2017 | 10/31/2017 | 10/31/2017 12:43:07 PM | A | PASS |
|
|
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn..ok to final
|
ELE17-03555
| Final | 10/31/2017 | 10/31/2017 | 10/31/2017 12:29:05 PM | P | PASS |
|
|
Randy Phone #: ###-####...ok to final
|
ELE17-03669
| Electrical Rough-In | 10/31/2017 | 10/31/2017 | 10/31/2017 12:07:56 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Ellliott....wrong address given for location of work being done...in different inspectors area...contractor will need to reschedule and attach right address to permit
|
ELE17-03672
| Permanent Service | 10/31/2017 | 10/31/2017 | 10/31/2017 11:41:52 AM | P | FAIL |
|
|
White door to the left of meter main is open if you need to go in and no one lives there house is empty. Phone #: ###-#### Inspection requested via web by Jay Symonds...
address life safety issues before power can be turned on 1) overhead power to shop needs proper clearance 16' or removed 2) overhead power to house over deck needs proper clearances - 12' 3) exterior light fixture needs reinstalled or wires safed off 4) panel needs labelling 5) pond by service- GFI protection of power serving pond or completely removal of power
|
ELE17-03663
| Final | 10/30/2017 | 10/31/2017 | 10/31/2017 10:50:05 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Mike Okamura...not ready...fixtures been removed
|
ELE17-03055
| Final | 10/30/2017 | 10/31/2017 | 10/31/2017 10:17:28 AM | A | PASS |
|
|
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn...ok to final
|
ELE17-02867
| Final | 10/30/2017 | 10/31/2017 | 10/31/2017 9:51:28 AM | A | PASS |
|
|
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn...ok to final
|
ELE17-03658
| Temporary Service | 10/30/2017 | 10/31/2017 | 10/31/2017 9:26:42 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn...t/s u/g new ok
|
ELE17-03659
| Temporary Service | 10/30/2017 | 10/31/2017 | 10/31/2017 9:19:06 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn...t/s u/g new ok
|
ELE17-03657
| Temporary Service | 10/30/2017 | 10/31/2017 | 10/31/2017 9:00:23 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn...t/s u/g new ok
|
ELE17-03656
| Temporary Service | 10/30/2017 | 10/31/2017 | 10/31/2017 8:41:04 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn...t/s u/g new ok
|
ELE17-03541
| Permanent Service | 10/30/2017 | 10/31/2017 | 10/31/2017 8:29:43 AM | A | PASS |
|
|
200 amp service Manufactured home Phone #: ###-#### Inspection requested via web by jamie berg...p/s u/g new ok
|
ELE15-01128
| Final | 10/27/2017 | 10/31/2017 | 10/30/2017 8:40:16 AM | P | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle...ok to final
|
ELE15-00802
| Final | 10/27/2017 | 10/31/2017 | 10/30/2017 8:39:49 AM | P | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle...ok to final
|