Inspections for the day of: Wednesday, October 31, 2018.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM17-04191 PLM-Aging Inspection10/31/201810/31/201810/31/2018 5:08:22 PM FAIL
check in spring
PLM18-03466 Plumbing Rough-in10/30/201810/31/201810/31/2018 4:49:15 PMPFAIL
Juan Phone #: ###-####
cleanouts require 24" clearan drain back graded- water lines in garage need raised into conditioned space- shower head lines in ceiling need insulated and tented- pex lines supported per ispc- water softner rough required- missing nailplatesce not behind toilet bowl- water line leak upstairs shower- humidifie
PLM18-03660 Final10/30/201810/31/201810/31/2018 3:14:52 PMPPASS
juan Phone #: ###-####
PLM18-04553 Final10/29/201810/31/201810/31/2018 2:44:48 PMPPASS
installer Travis ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
PLM18-04594 Pressure Test10/31/201810/31/201810/31/2018 2:41:53 PMPPASS
Tech-Thomas ###-#### Phone #: ###-#### Inspection requested via web by Nick Drake
20# o.k.
PLM18-04594 DOC - Permit Finaled10/31/201810/31/201810/31/2018 2:41:10 PMPPASS
20# ok
PLM18-03950 Med/Gas Systems10/31/201810/31/201810/31/2018 2:28:42 PMPPART
Please come at noon if available. Phone #: ###-#### Inspection requested via web by RM Mechanical start 24hr
PLM18-04583 Water and/or Sewer10/30/201810/31/201810/31/2018 1:41:37 PMPPASS
Matt is the tech if you have any questions ###-#### Phone #: ###-#### Inspection requested via web by Nick Drake
PLM18-04583 DOC - Permit Finaled10/31/201810/31/201810/31/2018 1:41:27 PMPPASS
no access to crawl meter not spinning
ok to cover
PLM18-04512 Groundwork10/30/201810/31/201810/31/2018 1:00:51 PMPPART
Come in off of Fry Street Beverly Street is closed. Phone #: ###-#### Inspection requested via web by RM Mechanical
trunk line and floor drain
PLM18-04052 Plumbing Rough-in10/30/201810/31/201810/31/2018 12:34:58 PMAFAIL
Phone #: ###-#### Inspection requested via web by Erin Whiting
1. strap vents at 4 foot spacing,-2. water closes too close to tum 15" minimun. 3. bring 3" cleanouts for both baths above floor or within 5 feet of crawl. 4. cleanouts must have 24" clear not behind w.c. facing bowl. 5. missing nailplates. 6. hot water lines below conditioned space to be insulated per energy code
PLM18-02287 Final10/30/201810/31/201810/31/2018 12:03:01 PMAPASS
give me a call to let you in thanks Phone #: ###-#### Inspection requested via web by Frank Young
PLM18-03769 Water Heater Final10/30/201810/31/201810/31/2018 11:01:05 AMAPASS
Re-inspection. Carolyne Neely Phone #: ###-#### Inspection requested via web by Heidi Lukecart
PLM18-04582 Final10/30/201810/31/201810/31/2018 10:56:26 AMAPASS
Dan Hinkle- New Leaf Electric ###-####. Nic Connell ###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart
PLM18-04358 Final10/31/201810/31/201810/31/2018 10:36:47 AMAPASS
premise protection was last tested 1995. palmer backflow tested and passes today
MIS18-00417 PLM-Conference10/30/201810/31/201810/31/2018 10:14:11 AMAPASS
Call ahead Izze Phone #: ###-####
the exiting plumbing was perm capped by the new tenant and covered with sheet rocked. There is no sewer gas smell. The existing sink plumbing is ok
PLM18-02320 Plumbing Rough-in10/30/201810/31/201810/31/2018 8:50:09 AMAPASS
vent inspection - if questions call Omar @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann
PLM18-04248 Final10/30/201810/31/201810/30/2018 9:31:49 PMACANC
Phone #: ###-#### >> Inspection requested via web by Todd Harris Inspection cancelled from web by: Todd Harris
PLM18-04588 Water Heater Final10/30/201810/31/201810/30/2018 4:55:57 PMPCANC
Phone #: ###-#### >> Inspection requested via web by Chris Field Inspection cancelled from web by: Chris Field