ELE19-03752
| Electrical Rough-In | 10/30/2019 | 10/31/2019 | 10/31/2019 2:28:59 PM | P | PASS |
|
|
Contact Travis for any questions Phone #: ###-#### Inspection requested via web by Vicki Moore... light poles x 2 bond weld at main building underground for east slab ok to pour and cover
|
ELE19-04152
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 1:58:24 PM | P | PASS |
|
|
Please come at 2:30 PM as Idaho Power will be out prior. Thanks. Phone #: ###-#### Inspection requested via web by Sarah Schuller... all in one added...existing panel made to sub panel...verified at perm service inspection...grounding updated...ok to final
|
ELE19-04152
| Permanent Service | 10/31/2019 | 10/31/2019 | 10/31/2019 1:56:59 PM | P | PASS |
|
|
Please come at 2:30 PM as Idaho Power will be out prior. Thanks. Phone #: ###-#### Inspection requested via web by Sarah Schuller... p/s u/g reconnect ok
|
ELE19-04198
| Final | 10/31/2019 | 10/31/2019 | 10/31/2019 1:39:45 PM | P | PASS |
|
|
Call ahead // Brian Phone #: ###-####.... ok to final all exterior work...homeowner gave ok to go behind fence for inspection...stayed on phone with electrical contractor as well
|
ELE19-04196
| Electrical Rough-In | 10/31/2019 | 10/31/2019 | 10/31/2019 1:04:47 PM | P | PASS |
|
|
trench cover inspection. electrician Matt Jones not onsite, ###-####. can call office for more details. Phone #: ###-#### Inspection requested via web by Matthew White... ok to cover...piping to shed in backyard
|
ELE19-02542
| Conference | 10/31/2019 | 10/31/2019 | 10/31/2019 12:31:15 PM | P | PASS |
|
|
MCC Phone #: ###-#### Inspection requested via web by Dan Cox... discussed service adjustments...needs to go back to city for approval...no stamp on plans adjustable breaker and wiring for it, lockability, and access to breaker AFC label and GFCI breaker testing-2 breakers 1000A and 1600A
|
ELE19-01489
| Permanent Service | 10/30/2019 | 10/31/2019 | 10/31/2019 11:19:14 AM | A | CANC |
|
|
Toby is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen... working on paperwork and info of testing of OCPD
|
ELE19-04165
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 11:11:22 AM | A | PASS |
|
|
extended conductors to relocate gas furnace from attic to utility room. Ready for inspection. Kelly is contact at ###-####.Please call when in route so we can notify customer. Thank You Phone #: ###-#### Inspection requested via web by Kelly Felin...ok to final
|
ELE19-04086
| Electrical Rough-In | 10/31/2019 | 10/31/2019 | 10/31/2019 10:43:31 AM | A | CANC |
|
|
Starting job this morning Phone #: ###-#### Inspection requested via web by Matt Oranday... UL listing verified all work outside LF side house know owner
|
ELE19-04181
| Electrical Rough-In | 10/30/2019 | 10/31/2019 | 10/31/2019 10:23:17 AM | A | PASS |
|
|
rough in for new wall on 2nd floor data room Phone #: ###-#### Inspection requested via web by Ron Zimmerman...ok to cover
|
ELE19-02499
| Final | 10/31/2019 | 10/31/2019 | 10/31/2019 9:49:58 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by GABE BEAL..addition complete...ok to final
|
ELE19-02499
| Conference | 10/30/2019 | 10/31/2019 | 10/31/2019 9:49:31 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by GABE BEAL...discussed requirements for adding wiring for mini split to addition...home owner deciding to hire electrician
|
ELE19-04140
| Electrical Rough-In | 10/30/2019 | 10/31/2019 | 10/31/2019 9:27:38 AM | A | NH |
|
|
Phone #: ###-#### Inspection requested via web by BRS Permitting... no one working...unable to verify reinspection fee applied and shall be paid before scheduling future inspections
|
ELE19-02943
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 9:20:59 AM | A | FAIL |
|
|
Please call Kevin ###-#### to meet you there or for access info. If you have any questions please feel free to contact Andrew ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan..
1) all 120V outlets in garage shall have GFCI protection 2) 120/240V outlets in garage shall be completely installed...plates OUTLETS MOVED IN GARAGE FOR WASHER AND DRYER 3) outside disconnects need proper labelling as too what breaker in panel is its OCPD 4) outlets for pantry counter need installed-no point along counter top wall line shall be more than 2ft without an outlet..210.52(C)(1)
|
ELE19-04120
| Rough-In Permanent Service | 10/30/2019 | 10/31/2019 | 10/31/2019 8:28:42 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn... ROUGH OK TO COVER P/S U/G NEW OK
|