ELE06-03647
| Rough-In Permanent Service | 10/2/2006 | 10/4/2006 | 10/4/2006 4:32:57 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 10/2/2006 at 7:49:39 AM. Contact: ###-####. called contr, left message, 334.30 nm cable shall be secured within 12" of box, flat cable shall not be stapled on edge (by garage door into house), 250.80 metal box shall be grounded, 300.4(A)&(D) edge of bored holes and nm cable shall be 11/4" from edge of framing member, 210.52(H) hallway over 10' shall have recpt installed, 210.52(A)(2) 2' wall in kitchen shall have recpt installed, BCC job id sticker shall be posted, all make-up shall be done
|
ELE06-03260
| Final | 10/4/2006 | 10/4/2006 | 10/4/2006 3:51:22 PM | P | PASS |
|
|
jason; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
|
ELE06-01859
| Permanent Service | 10/4/2006 | 10/4/2006 | 10/4/2006 3:01:16 PM | P | CANC |
|
|
Dennis; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt Contr said ok to put service in from prior agreement, but a violation of nec 314.28(A)(2) for junction box at ipco stub-up. Min size junction box shall be 24" . 324 said for contractor to arrange conference with ipco and city in am.
|
ELE06-02930
| Final | 10/4/2006 | 10/4/2006 | 10/4/2006 2:10:20 PM | P | PASS |
|
|
can you call an hour or so in advance so I can make sure the house has access. Thank you ; Phone #: ###-#### Internet Inspection Request from: Robert Murray ok to final
|
ELE06-03637
| Electrical Rough-In | 10/4/2006 | 10/4/2006 | 10/4/2006 1:42:47 PM | P | CANC |
|
|
corey; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles wrong type inspection, see rip
|
ELE06-03637
| Rough-In Permanent Service | 10/4/2006 | 10/4/2006 | 10/4/2006 1:38:42 PM | P | PASS |
|
|
corey; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ric ok, walls, clgs, p/s, exst meter pak, n, ok
|
ELE06-03280
| Electrical Rough-In | 10/3/2006 | 10/4/2006 | 10/4/2006 11:54:57 AM | A | PART |
|
|
Please inspect partial underground of D-wing.; Phone #: ###-#### Internet Inspection Request from: Jim Friend ok to cover part D-wing anop u/g and for lighting 3/4" as discussed
|
ELE06-03681
| Permanent Service | 10/3/2006 | 10/4/2006 | 10/4/2006 11:02:22 AM | A | PASS |
|
|
PLEASE INSPECT THE UPGRADE SERVICE ON TEH EXISTING BUILDING. THANK YOU.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH p/s u/g n ok, need to see more as job develops
|
ELE06-02767
| Final | 10/3/2006 | 10/4/2006 | 10/4/2006 10:56:05 AM | A | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Joe Thomas screen power and projector both need wired, no sign-off card, se office locked, called contr to finish and re-call
|
ELE06-03275
| Electrical Rough-In | 10/3/2006 | 10/4/2006 | 10/4/2006 9:57:19 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 10/3/2006 at 11:44:30 AM. Contact: ###-####. south 1/2 u/g ok to cover- entry area
|
ELE06-01391
| Permanent Service | 10/4/2006 | 10/4/2006 | 10/4/2006 9:55:16 AM | A | PASS |
|
|
p/s o/h n ok , notes from 8/1/06 in error, looked at today and ok for power
|
ELE06-02887
| Electrical Rough-In | 10/4/2006 | 10/4/2006 | 10/4/2006 9:34:27 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 10/4/2006 at 7:18:19 AM. Contact: ###-####. elect room, walls, hard lid sw part bldg ok to cover
|
ELE06-03620
| Conference | 10/3/2006 | 10/4/2006 | 10/4/2006 8:58:20 AM | A | DONE |
|
|
Conf at 8:30, if possible.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs talked about temp services required for a/c and how project would be built
|
ELE06-03620
| Permanent Service | 10/3/2006 | 10/4/2006 | 10/4/2006 8:53:12 AM | A | PASS |
|
|
At 8:30, if possible.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs p/s exst meter pak n ok
|