Inspections for the day of: Wednesday, October 4, 2006.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD05-01994 BLD-Aging Inspection10/4/200610/4/200610/10/2006 11:12:15 AM PASS
BLD06-00169 BLD-Aging Inspection10/4/200610/4/200610/4/2006 4:35:01 PM PASS
wip
BLD06-01623 BLD-Final10/3/200610/4/200610/4/2006 4:17:21 PMAPASS
Sherry; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt. No previous insp. were called in. Was able to inspect new store front framing, suspended ceiling grid and review special insp. report. ok for perm occ. Did note to contracror that this type of insp. would be unacceptable in the future.
BLD06-00271 BLD-Framing/Rough-in10/4/200610/4/200610/4/2006 3:49:34 PMPPASS
bob; Phone #: ###-#### Internet Inspection Request from: Patricia Smith. Exterior steel stud framing, and interior wood framed walls.
BLD05-02151 BLD-Final10/4/200610/4/200610/4/2006 3:29:30 PMPPEND
Scheduled by a contractor via Hello! on 10/4/2006 at 7:54:23 AM. Contact: ###-####. Will be ok for final once life/safety finals.
BLD06-02243 BLD-Framing/Rough-in10/2/200610/4/200610/4/2006 3:20:31 PMPFAIL
###-#### - michael. Finish nailing simpson hangar at 2 ply girder truss in garage. Provide fireblocking at furout wall up stairs at tub shower stall. Temp glass required at window above tub west wall upstairs. Need to provide engineering sub 2x6 framed wall at entry for 2x4 wall. provide landing at front door no more than 1.5 inch below threshhold.
BLD06-02241 BLD-Energy code compliance10/3/200610/4/200610/4/2006 2:52:57 PMPPASS
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. All framing issues have been resolved.
BLD06-02209 BLD-Conference10/4/200610/4/200610/4/2006 1:56:27 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Patricia Smith
BLD06-01811 BLD-Other10/3/200610/4/200610/4/2006 12:14:46 PMADEFR
martin Note: wall panel rebar; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Panels resceived special insp.
BLD05-02394 BLD-Final10/3/200610/4/200610/4/2006 12:14:12 PMAFAIL
jim; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. No handrails installed at ramp or stairs at front enterance. Riser height on conc. stairs at front enetrance exceed the max 7 inch allowable. Handrail not continous at new stairway. Needs to have ada accessible counters at cashier and service counter.
BLD06-02681 BLD-Final10/3/200610/4/200610/4/2006 11:06:28 AMAPASS
Bill (cell ###-####); Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
BLD06-02681 DOC - Permit Finaled10/4/200610/4/200610/4/2006 11:06:13 AMPPASS
Performed framing insp. also.
BLD06-01946 BLD-Footing10/4/200610/4/200610/4/2006 10:34:42 AMAPART
Scheduled by a contractor via Hello! on 10/4/2006 at 7:16:21 AM. Perimeter footings. Job will have special insp.
BLD06-02108 BLD-Framing/Rough-in10/3/200610/4/200610/4/2006 9:21:50 AMAPART
NEIL; Phone #: ###-#### Internet Inspection Request from: Patricia Smith. Exterior steel stud framing at east wall, upper tower and lower tower. Contractor to get rfi for sub of fillet welds to hilti shot pins at angle to bent plate connections.
BLD06-00982 DOC-Permit Expired10/4/200610/4/200610/4/2006 12:00:00 AM DONE
Permit expired by limitations.