BLD05-01994
| BLD-Aging Inspection | 10/4/2006 | 10/4/2006 | 10/10/2006 11:12:15 AM | | PASS |
|
|
|
BLD06-00169
| BLD-Aging Inspection | 10/4/2006 | 10/4/2006 | 10/4/2006 4:35:01 PM | | PASS |
|
|
wip
|
BLD06-01623
| BLD-Final | 10/3/2006 | 10/4/2006 | 10/4/2006 4:17:21 PM | A | PASS |
|
|
Sherry; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt. No previous insp. were called in. Was able to inspect new store front framing, suspended ceiling grid and review special insp. report. ok for perm occ. Did note to contracror that this type of insp. would be unacceptable in the future.
|
BLD06-00271
| BLD-Framing/Rough-in | 10/4/2006 | 10/4/2006 | 10/4/2006 3:49:34 PM | P | PASS |
|
|
bob; Phone #: ###-#### Internet Inspection Request from: Patricia Smith. Exterior steel stud framing, and interior wood framed walls.
|
BLD05-02151
| BLD-Final | 10/4/2006 | 10/4/2006 | 10/4/2006 3:29:30 PM | P | PEND |
|
|
Scheduled by a contractor via Hello! on 10/4/2006 at 7:54:23 AM. Contact: ###-####. Will be ok for final once life/safety finals.
|
BLD06-02243
| BLD-Framing/Rough-in | 10/2/2006 | 10/4/2006 | 10/4/2006 3:20:31 PM | P | FAIL |
|
|
###-#### - michael. Finish nailing simpson hangar at 2 ply girder truss in garage. Provide fireblocking at furout wall up stairs at tub shower stall. Temp glass required at window above tub west wall upstairs. Need to provide engineering sub 2x6 framed wall at entry for 2x4 wall. provide landing at front door no more than 1.5 inch below threshhold.
|
BLD06-02241
| BLD-Energy code compliance | 10/3/2006 | 10/4/2006 | 10/4/2006 2:52:57 PM | P | PASS |
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. All framing issues have been resolved.
|
BLD06-02209
| BLD-Conference | 10/4/2006 | 10/4/2006 | 10/4/2006 1:56:27 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Patricia Smith
|
BLD06-01811
| BLD-Other | 10/3/2006 | 10/4/2006 | 10/4/2006 12:14:46 PM | A | DEFR |
|
|
martin Note: wall panel rebar; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Panels resceived special insp.
|
BLD05-02394
| BLD-Final | 10/3/2006 | 10/4/2006 | 10/4/2006 12:14:12 PM | A | FAIL |
|
|
jim; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. No handrails installed at ramp or stairs at front enterance. Riser height on conc. stairs at front enetrance exceed the max 7 inch allowable. Handrail not continous at new stairway. Needs to have ada accessible counters at cashier and service counter.
|
BLD06-02681
| BLD-Final | 10/3/2006 | 10/4/2006 | 10/4/2006 11:06:28 AM | A | PASS |
|
|
Bill (cell ###-####); Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
|
BLD06-02681
| DOC - Permit Finaled | 10/4/2006 | 10/4/2006 | 10/4/2006 11:06:13 AM | P | PASS |
|
|
Performed framing insp. also.
|
BLD06-01946
| BLD-Footing | 10/4/2006 | 10/4/2006 | 10/4/2006 10:34:42 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 10/4/2006 at 7:16:21 AM. Perimeter footings. Job will have special insp.
|
BLD06-02108
| BLD-Framing/Rough-in | 10/3/2006 | 10/4/2006 | 10/4/2006 9:21:50 AM | A | PART |
|
|
NEIL; Phone #: ###-#### Internet Inspection Request from: Patricia Smith. Exterior steel stud framing at east wall, upper tower and lower tower. Contractor to get rfi for sub of fillet welds to hilti shot pins at angle to bent plate connections.
|
BLD06-00982
| DOC-Permit Expired | 10/4/2006 | 10/4/2006 | 10/4/2006 12:00:00 AM | | DONE |
|
|
Permit expired by limitations.
|