ELE07-03417
| Conference | 10/3/2007 | 10/4/2007 | 10/4/2007 4:19:11 PM | P | PART |
|
|
josh Phone #: ###-#### Note: please call 1/2 hr prior talked about insulation on knob and tube and replacement of same
|
ELE07-03102
| Final | 10/4/2007 | 10/4/2007 | 10/4/2007 3:38:00 PM | P | PASS |
|
|
please inspect for final. call Loren if any issues arise. thanks. Phone #: ###-#### Internet Inspection Request from: Loren Ramsey
|
ELE07-03086
| Final | 10/3/2007 | 10/4/2007 | 10/4/2007 2:56:30 PM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 10/3/2007 at 9:00:16 AM. Contact: ###-####.
|
ELE07-02776
| Final | 10/4/2007 | 10/4/2007 | 10/4/2007 2:17:35 PM | P | PASS |
|
|
Darryn Phone #: ###-####
|
ELE07-03391
| Conference | 10/4/2007 | 10/4/2007 | 10/4/2007 1:46:24 PM | P | PART |
|
|
brad Phone #: ###-#### talked about requirements for service and garage
|
ELE07-01893
| Final | 10/4/2007 | 10/4/2007 | 10/4/2007 1:07:23 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Curtis Dunham
|
ELE07-01893
| Permanent Service | 10/3/2007 | 10/4/2007 | 10/4/2007 1:06:54 PM | P | PASS |
|
|
owner to be at home in the afternoon Phone #: ###-#### Internet Inspection Request from: Curtis Dunham Inspection cancelled from web by: Curtis Dunham
|
ELE07-01893
| Final | 10/4/2007 | 10/4/2007 | 10/4/2007 1:06:42 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Curtis Dunham
|
ELE07-02416
| Electrical Rough-In | 10/3/2007 | 10/4/2007 | 10/4/2007 12:06:04 PM | A | PASS |
|
|
Need rough-in inspection for floor heat cable installed in master bathroom please, Thanks Phone #: ###-#### Internet Inspection Request from: ERIC CENTERS
|
ELE07-03396
| Rough-In Permanent Service | 10/3/2007 | 10/4/2007 | 10/4/2007 11:41:44 AM | A | PASS |
|
|
Inspection for BBQ center - around left side of house. Phone #: ###-#### Internet Inspection Request from: Kathy Briggs
|
ELE07-03418
| Rough-In Permanent Service | 10/3/2007 | 10/4/2007 | 10/4/2007 11:12:51 AM | A | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Paul Schepper service grounding done by state method splicing in the panel. R/I Ok
|
ELE07-02080
| Permanent Service | 10/3/2007 | 10/4/2007 | 10/4/2007 10:31:37 AM | A | NR |
|
|
eric Phone #: ###-#### undergorund R/I to house only.
|
ELE07-02080
| Electrical Rough-In | 10/4/2007 | 10/4/2007 | 10/4/2007 10:30:58 AM | P | PASS |
|
|
eric Phone #: ###-#### underground ok
|
ELE07-03330
| Electrical Rough-In | 10/4/2007 | 10/4/2007 | 10/4/2007 10:07:11 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 10/4/2007 at 7:22:39 AM. Contact: ###-####. south east area underground ok
|
ELE07-03423
| Temporary Service | 10/3/2007 | 10/4/2007 | 10/4/2007 9:31:56 AM | A | FAIL |
|
|
overhead temp service along fence thanks Phone #: ###-#### Internet Inspection Request from: Lynn Cable uncover eletrode install plastic connector and connect gec to neutral bus
|
ELE07-02787
| Electrical Rough-In | 10/3/2007 | 10/4/2007 | 10/4/2007 8:48:55 AM | A | FAIL |
|
|
rocky Phone #: ###-#### protect cable throughout
|
ELE07-01893
| Permanent Service | 10/3/2007 | 10/4/2007 | 10/3/2007 8:10:36 PM | P | CANC |
|
|
owner to be at home in the afternoon Phone #: ###-#### Internet Inspection Request from: Curtis Dunham Inspection cancelled from web by: Curtis Dunham
|