Inspections for the day of: Friday, October 4, 2013.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTroy James
TitleMEC-COM/RES INSPECTOR
Phone #794-9461
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC12-03948 Rough-in10/3/201310/4/201310/7/2013 8:21:39 AMAPASS
1st Floor grease duct light test Phone #: ###-#### >> Inspection requested via web by Allison Briggs
grease duct for the fork
MEC13-04000 Rough-in10/3/201310/4/201310/4/2013 3:46:02 PMPPASS
Ready after noon Phone #: ###-#### >> Inspection requested via web by Russ Curtis
20# gas test
MEC13-04040 Final10/3/201310/4/201310/4/2013 3:23:43 PMPPASS
>> Inspection requested via web by Don Dowers
MEC13-02475 Final10/3/201310/4/201310/4/2013 2:58:46 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Troy Worley
need air balance report for each furnace and need to complete air intake installations per page 24 of installation manual
MEC13-03521 Pressure Test10/3/201310/4/201310/4/2013 2:25:12 PMPPASS
CONTACT IS BRIAN HUFFMAN ###-#### Phone #: ###-#### >> Inspection requested via web by LENNIE BUSS
test to fireplace ok, need to hard pipe into firebox and make sure valve is accessable in firebox.
MEC13-00287 Pressure Test10/3/201310/4/201310/4/2013 1:57:09 PMAPASS
CONTACT IS COLIN ###-#### Phone #: ###-#### >> Inspection requested via web by LENNIE BUSS
ok pressure test to heating pipes
MEC13-03708 Rough-in10/3/201310/4/201310/4/2013 11:19:08 AMAPASS
Ceiling Cover Please. Call Matt Hines with any questions ###-#### Phone #: ###-#### >> Inspection requested via web by Sarah Rhodes
ok ceiling cover except at break room, need to inspect hydronics and condensate
MEC13-03033 Final10/2/201310/4/201310/4/2013 10:50:44 AMACANC
final schedule Phone #: ###-#### >> Inspection requested via web by Lisa Whitney
cannot final at this time
MEC13-03033 Rough-in10/4/201310/4/201310/4/2013 10:50:19 AMAPASS
final schedule Phone #: ###-#### >> Inspection requested via web by Lisa Whitney
20# test for duplex and rough ok, duct blast test ok
MEC13-04034 Final10/3/201310/4/201310/4/2013 10:24:45 AMAFAIL
TENANT HOME UNTIL 11:00 A.M. Phone #: ###-#### >> Inspection requested via web by PATRICK FLEMING
need water heater pan and drain to exterior, cannot use water flex supply for pressure relief drain and cannot create a trap, may need to run new drain pipe to exterior for pressure relief drain. seal hole outside fto a/c unit. Furnace flue needs to be double wall or remove shelves.
MEC13-03991 Final10/3/201310/4/201310/4/2013 9:55:26 AMAPASS
Call John so someone can meet you at the job site
###-#### Phone #: ###-#### >> Inspection requested via web by John Bertram
MEC13-04066 Rough-in10/3/201310/4/201310/4/2013 9:35:00 AMAPASS
phone number is for the home owner Rose. This will need a rough and final as it is a gas insert addition. Thank you, Rick. Phone #: ###-#### >> Inspection requested via web by Mike Almanza
MEC13-04066 Final10/4/201310/4/201310/4/2013 9:34:50 AMPPASS
phone number is for the home owner Rose. This will need a rough and final as it is a gas insert addition. Thank you, Rick. Phone #: ###-#### >> Inspection requested via web by Mike Almanza
MEC13-03919 Final10/1/201310/4/201310/4/2013 9:21:52 AMAFAIL
Pls call customer prior to inspect Phone #: ###-#### >> Inspection requested via web by Echo Jackson
c/n posted