Inspections for the day of: Wednesday, October 4, 2017.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-02517 Electrical Rough-In9/27/201710/4/201710/4/2017 12:33:36 PMPPASS
Jen Phone #: ###-#### xt 123 Check all raintight fittings. Make sure they are all made wrench tight. UL Listing of equipment only rough in ok
ELE17-02588 Final10/4/201710/4/201710/4/2017 12:31:19 PMPPASS
Garage Code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
ELE17-02621 Final10/3/201710/4/201710/4/2017 11:54:22 AMAFAIL
Jenn ext 123 Phone #: ###-#### All rain tight connectors shall be made wrench tight as per manufacturer specifications.
ELE17-03009 Final10/4/201710/4/201710/4/2017 11:33:33 AMPPASS
The homeowner will be there all day. Robert ###-####. If you have any questions please call Clay ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clay Morgan Final ok
ELE17-02042 Final10/3/201710/4/201710/4/2017 11:22:39 AMAFAIL
Phone #: ###-#### Inspection requested via web by steve cooper GFCI test on floor heat T stat not functioning. 210.11 C2 and C3. Laundry room 20 Branch circuit shall have no other outlets, Bathroom 20 branch circuit shall have no other outlets.
ELE17-02824 Final10/3/201710/4/201710/4/2017 11:19:04 AMAFAIL
Phone #: ###-#### Inspection requested via web by steve cooper GFCI test on floor heat T stat not functioning. 210.11 C2 and C3. Laundry room 20 Branch circuit shall have no other outlets, Bathroom 20 branch circuit shall have no other outlets.
ELE17-03342 Conference10/4/201710/4/201710/4/2017 10:32:04 AMPCANC
Ground works inspection Phone #: ###-#### Inspection requested via web by Don Conley needed rough in
ELE17-03342 Electrical Rough-In10/4/201710/4/201710/4/2017 10:30:21 AMPPASS
Ground works inspection Phone #: ###-#### Inspection requested via web by Don Conley underground from house to shop only ok to cover
ELE17-02479 Final10/3/201710/4/201710/4/2017 9:56:03 AMAPASS
Garage code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk corrections made final ok
ELE17-03334 Electrical Rough-In10/3/201710/4/201710/4/2017 9:31:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Jose Guerrero Needed perm serv
ELE17-03334 Permanent Service10/4/201710/4/201710/4/2017 9:31:07 AMPPASS
Phone #: ###-#### Inspection requested via web by Jose Guerrero p/s o/h rec ok
ELE17-03334 Conference10/3/201710/4/201710/4/2017 6:51:18 AMAPASS
Talk to Jose Phone #: ###-#### Inspection requested via web by Jose Guerrero Talked about panel location and clearences. Running Service entrance surface mount to new panel location. Existing meterbase Clearance and service drop location OK'd by ID Power.
ELE16-02746 Electrical Rough-In10/4/201710/4/201710/4/2017 12:00:00 AMPCANC
Rough cover 209-218 309-318 Phone #: ###-#### Inspection requested via web by Kenneth Chapman
ELE16-02746 Electrical Rough-In10/4/201710/4/201710/4/2017 12:00:00 AMPPART
Rough cover 209-218 309-318 Phone #: ###-#### Inspection requested via web by Kenneth Chapman 311 Missing W/P. 314 Missing KO seals in Kitchen and Living lights. Other rooms listed OK to cover
ELE17-01718 Final10/3/201710/4/201710/3/2017 1:10:21 PMAPASS
Phone #: ###-#### Inspection requested via web by John VanZandt corrections made final ok