Inspections for the day of: Thursday, October 5, 2006.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-03504 Electrical Rough-In10/5/200610/5/200610/5/2006 2:49:36 PMPPASS
Scheduled by a contractor via Hello! on 10/5/2006 at 6:57:14 AM. Contact: ###-####. u/g post light
ELE06-03503 Electrical Rough-In10/5/200610/5/200610/5/2006 2:49:14 PMPPASS
u/g post light
ELE06-01294 Final10/5/200610/5/200610/5/2006 2:22:36 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Tye Tullis ok no card
ELE06-03597 Electrical Rough-In10/4/200610/5/200610/5/2006 2:13:14 PMPPART
Scheduled by a contractor via Hello! on 10/4/2006 at 6:16:21 PM. Contact: ###-####.u/g ok
ELE06-03534 Electrical Rough-In10/5/200610/5/200610/5/2006 1:23:34 PMPPASS
chad; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles r/i ok corrections made
ELE06-03701 Electrical Rough-In10/5/200610/5/200610/5/2006 1:06:32 PMPNR
john; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles not ready called listing for jtub?, 300.4 nail plates and 11/4" for low voltage wiring ENT and cables
ELE06-03526 Electrical Rough-In10/4/200610/5/200610/5/2006 10:41:16 AMAFAIL
shannon; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
corr. called 210.52(A&B) shall install required outlets for wall space on SABC for din rm, 210.70 3way for stairs 334.23 protect cables attic access
ELE06-01957 Final10/3/200610/5/200610/5/2006 10:38:36 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Tracy Robertson
ELE06-02426 Electrical Rough-In10/4/200610/5/200610/5/2006 9:54:30 AMAPART
One light pole has been eliminated, due to not being able to cross irrigation pipe.; Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot u/g ok
ELE06-02364 Electrical Rough-In10/4/200610/5/200610/5/2006 9:25:11 AMAPART
Scheduled by a contractor via Hello! on 10/4/2006 at 2:50:05 PM. Contact: ###-####. front outside u/g and lights
ELE06-02075 Electrical Rough-In10/4/200610/5/200610/5/2006 9:00:58 AMAPART
scott - underground trench insp; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok
ELE05-02003 Electrical Rough-In10/5/200610/5/200610/5/2006 8:42:41 AMAPART
Scheduled by a contractor via Hello! on 10/5/2006 at 7:03:52 AM. Contact: ###-####. ceiling in billiards rm
ELE06-00422 ELE-Aging Inspection10/5/200610/5/200610/5/2006 7:58:29 AM PART
wsuc
ELE06-00628 ELE-Aging Inspection10/5/200610/5/200610/5/2006 7:57:03 AM PART
wsuc