Inspections for the day of: Monday, October 5, 2009.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-00919 ELE-Aging Inspection10/5/200910/5/200910/6/2009 3:49:30 PM DONE
drove by, met rp, said job on hold, no esc this project
ELE09-00918 ELE-Aging Inspection10/5/200910/5/200910/6/2009 3:44:15 PM DONE
drove by, talked to rp, said job on hold, no esc this project
ELE09-01877 Final10/5/200910/5/200910/5/2009 4:10:31 PMPPASS
ok to final, checked circuit and panel schedule, called contractor, no esc this project
ELE09-01885 Final10/2/200910/5/200910/5/2009 4:07:54 PMPPASS
Please call prior to gain access Phone #: ###-#### Internet Inspection Request from: John Edwards called contractor to tie to bld, ok to final, signed card, no esc this project
ESC09-00553 General Inspection10/5/200910/5/200910/5/2009 3:41:13 PMPPASS
looked ok
ELE09-01877 Electrical Rough-In10/5/200910/5/200910/5/2009 3:36:58 PMPPASS
Matt Brown-Please call for access Phone #: ###-#### ric ok, no esc this project
ELE09-01894 Permanent Service10/5/200910/5/200910/5/2009 2:26:55 PMPPASS
Rick Phone #: ###-#### p/s o/h rec ok, no esc this project
ELE09-01867 Permanent Service10/5/200910/5/200910/5/2009 1:34:55 PMPFAIL
larry Phone #: ###-#### called, left correction notice,NEC 230.24(A) conductors shall be 8' above roof, 250.52(A) shall utilize interior metal water pipe within 5' of entering building for gec, 250.56 shall install 2 ground rods minimum 6' apart, no esc this project
ELE09-00796 ELE-Aging Inspection10/5/200910/5/200910/5/2009 11:46:59 AM DONE
called, no answer, no activity, waiting for contractor to call
ELE09-01879 Electrical Rough-In10/2/200910/5/200910/5/2009 10:25:55 AMACANC
Kevin Phone #: ###-#### customer called 414 and said he could not be there, so cancel and he will recall, no esc this project
ELE09-01813 Electrical Rough-In10/2/200910/5/200910/5/2009 9:58:00 AMAPART
Requesting a partial ceiling inspection to cover. Phone #: ###-#### Internet Inspection Request from: Dan Hardisty ok to cover entry ceiling only, no esc this project
ELE09-01824 Temporary Service10/2/200910/5/200910/5/2009 8:55:33 AMAPASS
Please meet me at the job site at 8:30 am on oct 5.Thanks Bruce
Phone #: ###-#### Internet Inspection Request from: Bruce Herold corrections made, t/s u/g n ok, no esc this project
ELE09-01892 Rough-In Permanent Service10/2/200910/5/200910/5/2009 8:09:02 AMAPASS
TOM Phone #: ###-#### called contractor, ric ok, p/s u/g n ok