Inspections for the day of: Friday, October 5, 2012.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-01766 ELE-Aging Inspection10/5/201210/5/201210/8/2012 10:24:13 AM DONE
still under construction
ELE09-01975 ELE-Aging Inspection10/5/201210/5/201210/8/2012 10:18:34 AM DONE
still under construction
ELE09-01904 ELE-Aging Inspection10/5/201210/5/201210/8/2012 10:17:38 AM DONE
still under construction
ELE11-02855 Electrical Rough-In10/5/201210/5/201210/5/2012 2:35:20 PMPPASS
ceiling//Steve Phone #: ###-#### 2 entry lights ok cover, suggested inspections cover more than 2 lights, will initial prints later
ELE12-02453 Electrical Rough-In10/5/201210/5/201210/5/2012 1:58:59 PMPNR
cover inspection Phone #: ###-#### >> Inspection requested via web by Tyler Bowen contractor had trouble with equipment, will recall
ELE12-02470 Rough-In Permanent Service10/5/201210/5/201210/5/2012 1:57:04 PMPPASS
ri ok, p/s u/g n ok
ELE12-02375 Final10/5/201210/5/201210/5/2012 1:54:09 PMPPASS
Panel and outlets / lights with new shop walls. Thank you! Phone #: ###-#### >> Inspection requested via web by Adam Staigle ok final, signed card
ELE12-00764 Final10/4/201210/5/201210/5/2012 1:36:19 PMPFAIL
Dave Phone #: ###-#### explained that devices not to be installed, outlet spacing, stapling, 6" free conductor length, shall use connector for ground wires in box, call for ri next time
ELE12-01768 Electrical Rough-In10/5/201210/5/201210/5/2012 12:20:54 PMPPASS
Requesting an inspection for 3 rooms. Phone #: ###-#### >> Inspection requested via web by Dan Hardisty ok cover ceilings
ELE12-02083 Final10/5/201210/5/201210/5/2012 10:34:40 AMPPASS
Please contact Cody with any questions ####-#### Phone #: ###-#### >> Inspection requested via web by Tracy Robertson b ok final
ELE12-01955 Final10/4/201210/5/201210/5/2012 10:14:12 AMAPASS
Call Dene with access code
Thank you Phone #: ###-#### >> Inspection requested via web by kim grundhauser ok final
ELE12-02455 Rough-In Permanent Service10/4/201210/5/201210/5/2012 10:12:44 AMAPASS
ri ok, p/s u/g n ok
ELE12-02470 Rough-In Permanent Service10/4/201210/5/201210/5/2012 9:08:04 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI called, shall provide 1 1/4" from framing member face to edge of nm cable, shall not be screws in box, boxes shall be flush with finished surface, shall add receptacle in 2' wall
ELE12-02040 Electrical Rough-In10/4/201210/5/201210/5/2012 8:33:13 AMAPASS
radiant heat//the ohlm ratings are on a paper on the box//Ron Phone #: ###-#### floor heat only ok cover
ELE12-02477 Permanent Service10/4/201210/5/201210/5/2012 8:18:00 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey called, left message. shall provide panel cover, gec shall be continous